Development & Optimization
Medium
Prior to using our own device for detection of fluorescence emitted by the sensor chips we used equipment readily available in the lab. A Molecular Imager® Gel DocTM XR+ from BIO-RAD was available which uses UV and white light illuminators. However, only two different filters were available for the excitation ligth wavelength, which resulted in very limitted possibilities for the excitation of fluorescent molecules. For example, it was possible to detect the expression of iLOV in our sensor chips but the detection of GFP was not possible. It was thus determined that the Gel DocTM XR+ was not suitable for our project.
Regarding the medium used for our sensor chips, LB medium showed a high background fluorescence when exposed to UV light. Surprinsingly, the background fluorescence resulting from the LB medium was to high to detect a signal emitted by our sensor cells. Instead we tried using minimal media (NA, M9, Hartman) in order to minimize background fluorescence. The appliction of minimal media was sufficient to minimize the background fluorescence, but this approach came with the drawback of minimal to zero growth of our sensor cells.
Further experiments were conducted to test long-time storage of the sensor chips. Storage at -20 °C resulted in the loss of our sensor cells. Adding 5-10% (v/v) glycerol ensured survival of the sensor cells, but resulted in an expression stop of fluorescence proteins. Thus, the idea of long time storage of the sensor chips had to be passed on. However, it was possible to store ready-to-use sensor chips for 2 days at 4 °C when using LB medium and storage for 5 days was possible with chips made from TB medium.
In our device WatsOn, optimized wavelengths of 450 nm and 480 nm were used for excitation of iLOV and GFP, respectively. When exposed to either excitation wavelength the TB medium showed minimal background fluorescence and no difficulties were observed in cultivation of our Cellocks. Furthermore, a reduction of background fluorescence compared to TB medium was observed when using LB medium for sensor chip manufacturing in combination with fluorescence evaluation using WatsOn.
Agar Concentration
For the sensor chip manufacturing, a concentration of 1.5 % agarose was found to be optimal. When agarose concentrations below 1.5 % (w/v) were used the sensor chips were easily damaged and were not transportable. Agar concentrations above 1.5 % (w/v) had to be avoided, because the agarose started to solidify before it could be poured into the chip casting mold.
Agarose was chosen above agar, because of more even linkage resulting in a better chip homogenity. In addition, agarose reduced diffusion of inducer molecules through the chip. A reduced diffusion was desired in order to achieve distinct fluorescent spots on the sensor chips.
Chip Form
Various approaches were tried for production of sensor chips with reproducable quality. The first approach was to cast every sensor chip individually. In order to achieve a plain chip surface, which was required for high quality images, we tried to cast the sensor chips between four microscope slides. This approach had to be rejected, because the agar was too liquid. In a second try, we produced a closed mold into which liquid agar was injected using a pipette, but we encountered a high number of bubbles in the chips when using this method. Bubbles in the sensor chips resulted in problems during fluorescence evalutaion.
Finally, we used an open mold into which the agar was poured right after mixing with the sensor cells. When the agar had solidified the chips were cut out along precast indentations in the casting mold. An advantage of the open mold was the ability to simultaneously produce nine sensor chips while the surface tension of the liquid agar ensured a plane chip surface.
Induction
For the induction of the used molecular constructs we simluated the presence of P. aeruginosa by using IPTG or 3-oxo-C12 HSL. The sensor cells with K1319042 in BL21 cells can detect a IPTG concentration of 1 mM (0.2 µL).
The sensor with the REACh constructs in BL21 cells also can detect an IPTG concentration of 1 mM (2 µL)
The sensor cells with [http://parts.igem.org/Part:BBa_K131026 K131026] in BL21 cells can detect an HSL concentration of 500 µg/mL (0.2 µL) and it can detect Pseudomonas aeruginosa.
(see Achievements)
|