Team:Dundee/Safety/normal

From 2014.igem.org

Revision as of 19:44, 17 October 2014 by DBurrell7 (Talk | contribs)

Dundee 2014

Safety and Protocols

Better Safe Than Sorry!

Safety

The Lung Ranger project has resulted in the construction of a device (the L.A.S.S.O.) intended to be used initially by healthcare workers (and potentially in the longer term by cystic fibrosis patients themselves). Therefore, the team felt that it was essential to implement a short list of well-considered safety protocols to ensure that:

1. Users do not come into direct contact with microorganisms, genetically modified or otherwise
2. Genetically modified microorganisms do not come into contact with wild-type microorganisms which could result in horizontal gene-transfer
3. Genetically modified organisms are disposed of safely

This has resulted in the design and prototyping of a set of components and practices to be utilised in the first instance by trained medical staff in the context of home-visits to cystic fibrosis patients.

Distribution and Storage of Genetically Modified Microorganisms

Sealed LB-Agar plates containing freeze-dried cultures of our modified E.coli would be distributed to cystic fibrosis clinics where they would be stored in the dark at 4 oC.

Rehydration of Freeze-Dried Cultures

On the day prior to a home-visit, water would be added to cultures with a sterile syringe via a one-way, filter-sterilizing valve and the plates incubated at 37 oC overnight. This would be carried out by a member of the clinical staff at the clinic and following training by a member of The Lung Ranger team.

Addition of Sputum to Rehydrated Cultures

On the day of testing, at the patient's home sputum samples would be collected in a sterile syringe that would then be fitted to a plate via a threaded valve (Fig 2). After ensuring that the syringe has been secured to the valve, the plunger would be depressed to add the sputum to the culture. It may be necessary, due to the variability in sputum viscosity, to aspirate Sputolysin® - a reducing agent- along with the sputum sample to sufficiently thin the sample for ease of use. the filter sterilising valve will prevent wild-type microorganisms from contacting the genetically modified bacteria inside the plate and thus removing the possibility of any uptake of transgenes by other organisms.

Processing of Samples

The plate containing a sputum sample would be agitated by hand to ensure adequate coverage of the medium by the sputum before being placed in the L.A.S.S.O. (Fig 4). After light detection, the plate would be transferred to a waste compartment by depressing the plunger-arm (Fig 5). The plunger-arm would be reset and the process can be repeated until the waste compartment is filled.

Removal of Used Culture Plates

The L.A.S.S.O. can be separated into two sections (Fig 6), allowing the waste compartment when full, to be either emptied or replaced with an empty compartment. In either case, the spent samples would be placed into a sealable bag and would be removed for autoclaving by the health worker ensuring the safe disposal of the genetically modified organisms.


Safety Form

This is our original Safety Form submitted to iGEM on 1st September 2014.

https://static.igem.org/mediawiki/2014/f/fa/DUN_Safety_Form_Transcript.pdf

Protocols

Competent Cells


Day 1

1. Streak out frozen glycerol stock of bacterial cells onto an LB plate (no antibiotics). Work sterile. Grow cells overnight at 37 oC.

Day 2

2. Select a single colony of E. coli from fresh LB plate and inoculate a 5 ml starter culture of LB (with no antibiotics). Grow at 37 oC in shaker overnight.

Day 3


3. Inoculate 50 ml fresh growth medium with 500 μl starter culture and grow at 37 oC for 2 hours.
4. When OD600 reaches 0.35-0.4, immediately put the cells on ice, chill the culture for 20-30 minutes, swirling occasionally to ensure even cooling. Chill centrifuge bottles on ice.
5. Harvest the cells by centrifugation at 3000g (around 4000rpm in the Beckman Ja-10 rotor) for 15 minutes at 4 oC.
6. Decant the supernatant and gently resuspend each pellet in about 5 ml of ice-cold transformation buffer1.
7. Aliquot in 200 μl batches into sterile 1.5 ml microcentrifuge tubes and snap freeze with liquid nitrogen.
Store frozen cells at -80 oC.


Polymerase Chain Reaction (PCR)

This protocol can be used to amplify the target genes required for the biosensors from genomic DNA and add appropriate restriction sites required for ligation into the vector pUniprom. Primers were supplied by Sigma-Aldrich, the DNA polymerase used was Herculase II Fusion DNA Polymerase which was supplied by Aligent Technologies.

Set up Standard PCR reaction (final volume = 50 μl):

Component Volume (μl)
5x Herculase buffer 10
100 μM forward primer 0.5
100 μM reverse primer 0.5
10 mM dNTPs 0.5
DMSO 2.5
H20 34.5
gDNA 1
Herculase II 0.5


Thermocycler protocol

Cycle(s) Time/Temp Process
1 3 mins at 95 oC Denature DNA
30 1 min at 95 oC DNA denatures into single strands
0.5 min at 75 oC Primers bind to DNA template
1 min/kb at 68 oC Primers extended 5’-3’ (1 min/kb)-elongation phase
1 5 min at 72 oC Final elongation
10 oC Final hold

Agarose Gel Electrophoresis

DNA products were run on a 1% agarose gel to separate charged nucleic acids by size for analysis/purification.

GelRed was used to stain nucleic acids and gels were visualised on a BioRad GelDoc.

Standard 1% agarose gel

1. Measure 1g of agarose.
2. Pour agarose powder to 100 ml of 1xTAE1 (tris-acetate EDTA buffer) in a microwavable flask.
3. Microwave until agarose has dissolved (1-3 mins) and there is a rolling boil - Caution HOT!
4. Allow solution to cool down.
5. Add Gel Red (6 µl per 100 ml 1% agarose solution).
6. Pour cooled agarose solution into a gel tray and place required combs in place (prevent any air bubbles).
7. Allow poured gel to sit on bench top for 20-30 minutes to solidify.
8. Once gel has solidified, remove the comb and place gel into the electrophoresis unit.
9. Fill the gel tank with 1xTAE.
10. Carefully load DNA weight ladder into the first lane of the gel.
11. Carefully load samples into the additional wells of the gel (be careful not to disturb the wells).
12. Run the gel at 100 V for 30 mins until the dye line is approximately 75-80% of the way down the gel.
13. Turn off the power, disconnect the electrodes from the power source and then carefully remove the gel from the gel box.
14. UV light used to visualize the DNA fragments.


Gel Extraction

QIAquick gel Extraction Kit Protocol designed to extract and purify DNA of 70 bp to 10 kb from standard or low-melt agarose gels in TAE buffer.

1. Excise the DNA fragment from the agarose gel with a clean, sharp scalpel.
2. Weigh the gel slice in a colorless tube. Add 3 volumes of Buffer QG to 1 volume of gel (100 mg=100 μl).
3. Incubate at 50 oC for 10 min (or until the gel slice has completely dissolved). To help dissolve gel, mix by vortexing the tube every 2-3 min during the incubation.
4. After the gel slice has dissolved completely, check that the colour of the mixture is yellow.
5. Add 1 gel volume of isopropanol to the sample and mix.
6. if the DNA will be subsequently used for sequencing, in vitro transcription, or microinjection, add 500 μl Buffer QG to the QIAquick column and centrifuge for 1 min. Discard flow-through and place the QIAquick column back into the same tube.
7. To wash, add 750 μl Buffer PE to QIAquick column and centrifuge for 1 min. Discard flow-through and place the QIAquick column back into the same tube. Centrifuge the QIAquick column in the provided 2 ml collection tube for 1 min to remove residual wash buffer.
8. Place QIAquick into a clean 1.5 ml microcentrifuge tube.
9. To elute DNA, add 50 μl of water to the centre of the QIAquick membrane and centrifuge the column for 1 min. For increased DNA concentration, add 30 µl water to the centre of the QIAquick membrane, let stand for 1min, and then centrifuge for 1 min.
10. If the purified DNA is to be analysed on a gel, add 1 volume of loading dye to 5 volumes of purified DNA.


Restriction Digests

Restriction Digests were performed to prepare DNA for ligation. Digests were carried out using enzymes supplied by Roche and New England Biolabs. Digests were performed at 37 oC for 3 hours.

An aliguot of alkaline phosphatase was added to restriction digests of vectors at 2 hrs and a second aliquot at 2.5 hrs Reactions were stopped after three hours. Digested PCR products were separated from restriction enzymes and buffers using Strataclean resin (Aligent Technologies). Digested vectors were purified on a 1% agarose gel and then extracted.

60 μl reactions following PCR:

1. 50 μl PCR product
2. 1.5 μl restriction enzyme 1
3. 1.5 μl restriction enzyme 2
4. 6 μl cognate digestion Buffer for enzyme(s)
5. 1 μl H20


Heatblock for 3 hours at 37 oC


Strataclean

√RD sample= volume of Strataclean
√60= 7.745 μl

1. Ensure Strataclean is vortexed before use.
2. Add 7.75 μl to each restriction digest.
3. Vortex for 15 sec and then centrifuge for 1 min at 13,000rpm in a microfuge.
4. Pipette supernatant into a clean microcentrifuge tube.


Ligations

For ligation of genes into vectors, the digested gene of interest and the appropriate vector were incubated with T4 DNA ligase at room temperature for 3 hrs.

Total reaction volume= 10 μl

Cycles Vector Only 2:1 3:1
10x T4 ligase buffer 1 μl 1 μl 1 μl
Insert - 2 μl 2μl
Vector 1 μl 1 μl 1 μl
T4 ligase 1 μl 1 μl 1 μl
H2o 7 μl 5 μl 4 μl

N.b. T4 ligase added last to the reaction.


Heat Shock Transformation of competent cells

Plasmids or ligation products containing the desired genes were transformed into chemocompetent E. coli cells.

1. Thaw competent cells on ice. Usually 10-20 minutes.
2. Pipette 100 μl of cells into a pre-chilled eppendorf tube.
3. Add 10 μl of ligation reaction or 2 μl of mini prepped plasmid.
4. Mix by gently flicking the tube.
5. Chill on ice for 30 minutes.
6. Heat shock at 42 oC for 90 seconds.
7. Return to ice for 2 minutes.
8. Add 1 ml of LB medium to cells and recover by shaking at 37 oC (ampicillin selection requires less recovery time than chloramphenicol selection).
9. Centrifuge for 3 minutes.
10. Remove supernatant and resuspend in 100 μl of LB.
11. Plate out the cells on selective LB agar plates containing appropriate antibiotics and spread using sterile glass spreader.
12. Incubate overnight at 37 oC.


Colony PCR

PCR was used to identify the desired clones on the plate of transformed cells. PCR was performed on the samples using Taq polymerase supplied by Aligent Technologies.

DNA preparation

1. Pick a single colony and twizzle into 30 μl of nuclease-free H2O.
2. Boil for 10 minutes at 100 oC to lyse cells.
3. Centrifuge for 1 minute at 13000rpm in a microfuge.
4. 5 μl of DNA was then used as part of the reaction mixture outlined below.

Colony PCR reaction

Prepare the following PCR reaction on ice (N.B. adding the enzyme last):


Component Volume (μl)
10x PCR reaction Mg (Roche) 2
100 μM forward primer 0.2
100 μM reverse primer 0.2
10 mM dNTPs 0.2
DMSO 2
Template DNA 5
H20 11.2
Taq Polymerase 0.5


Thermocycler Protocol

Cycle(s) Time/Temp Process
1 3 mins at 95 oC Denature DNA
30 1 min at 95 oC DNA denatures into single strands
0.5 min at 75 oC Primers bind to DNA template
1 min/kb at 68 oC Primers extended 5’-3’ (1 min/kb)-elongation phase
1 5 min at 72 oC Final elongation
10 oC Final hold


Plasmid Miniprep

Plasmids were isolated using a QIAprep Spin Miniprep Kit Protocol.

A 5 ml overnight culture of cells was centrifuged at 4000rpm for 10 min. The resulting pellet was lysed in an alkaline lysis buffer and centrifuged. Supernatant is passed through a silica membrane to isolate plasmid DNA.

1. Resuspend pelleted bacterial cells in 250 μl Buffer P1 and transfer to a microcentrifuge tube.
N.b. Ensure that RNase A has been added to Buffer P1.
2. Add 250 μl Buffer P2 and gently invert the tube 4-6 times to mix.
Mix gently by inverting the tube. Do not vortex, as this can result in shearing of genomic DNA.
N.b. Do not allow the lysis reaction to proceed for more than 5 min.
3. Add 350 μl Buffer N3 and invert the tube immediately but gently 4-6 times.
4. Centrifuge for 10 min at 13,000 rpm in a microfuge.
5. Apply the supernatant from step 4 to the QIAprep Spin column by decanting or pipetting.
6. Centrifuge for 30-60 seconds. Discard the flow-through.
7. (Optional): wash the QIAPrep Spin Column by adding 0.5ml Buffer PB and centrifuging for 30-60 seconds. Discard the flow-through.
8. Wash QIAPrep Spin column by adding 0.7 ml of Buffer PE and centrifuging for 30-60s.
9. Discard the flow-through, and centrifuge for an additional 1 min to remove residual wash buffer.
10. Place the QIAprep column in a clean 1.5 ml microcentrifuge tube. To elute DNA, add 50 μl water to the centre of each QIAprep Spin column, let stand for 1 min, and centrifuge for 1 min.


Site directed mutagenesis (QuikChange™)

Site directed mutagenesis was used to remove internal restriction sites from genes. The method relies on PCR using primers containing a single nucleotide mutation, which maintains the amino acid sequence and has specificity 15 bp up- and downstream of the target nucleotide. Herculase II polymerase was used in PCR reactions to amplify the target plasmid containing the mutation. PCR products were digested with the restriction enzyme DpnI to remove any methylated DNA leaving only the PCR product.


PCR reaction

Component 0.5x DNA template mixture (μl) 3x DNA template mixture (μl)
5x Herculase buffer 10 10
100 μM forward primer 1 1
100 μM reverse primer 1 1
10 mM dNTP 1 1
H20 36.5 34
DNA template 0.5 3
Herculase II 1 10


Thermocycler protocol

Cycle (s) Time/Temp Process
1 3 mins at 95 oC Denature DNA
30 1 min at 95 oC DNA denatures into single strands
0.5 min at 75 oC Primers bind to DNA template
1 min/kb at 68 oC Primers extended 5’-3’ (1 min/kb)-elongation phase
1 5 min at 72 oC Final elongation
10 oC Final Hold


Run a 5 µl aliquot of each PCR product on a 1 % agarose gel to check for amplified target gene. Digest PCR products with restriction enzyme DpnI for 3 hours at 37 oC to remove any methylated DNA leaving only the PCR product. 5 μl or 10 μl of PCR product then transformed into competent E. coli cells and plated onto appropriate LB selective media.


Glycerol Stock

1. Pick single colonies from agar plate.
2. Inoculate 5 ml LB broth overnight.
3. Add 1 ml of overnight culture to 1 ml of 60 % glycerol in a cryotube.
4. Freeze at -80 oC.


Testing the biosensors

In order to test our complete biosensors the following protocol was followed:

1. Prepare 5 ml O/N cultures in LB medium containing the completed constructs supplemented with appropriate antibiotics.
2. Following 16 hr of growth at 37 oC, subculture each sample into fresh growth medium (1:100.)
3. Spike cultures with saturating concentrations of synthetic signalling molecules.
4. Grow cultures for a further 2 hours to allow sufficient time for GFP /mCherry production.
5. Take 1 ml aliquots and proceed with western blot protocol.


Cell Fractionation

In order to test our complete biosensors the following protocol was followed:

1. Inoculate 5 ml of LB growth medium supplemented with appropriate antibiotic.
2. Allow 16 hr growth at 37 oC and then subculture into 100 ml of fresh growth medium (1:100 dilution).
3. Grow cells for a further 8 hours and pellet by centrifugation.
4. Wash pellet once in 50 mM Tris-HCl, pH 7.5.
5. Repellet the cells and then resuspend in 2 ml of the same buffer.
6. Lyse by sanitation.
7. Centrifuge sonicated samples to remove unbroken cells.
8. Ultracentrifuge the supernatant to pellet the cell membranes.
9. Remove the supernatant (corresponds to the soluble fraction of the cell).
10. Resuspend membrane pellet in 1 ml of 50 mM Tris-HCl, pH 7.5.
11. Separate 10 μl of the samples by SDS PAGE (12 % acrylamide), transfer to PVDF and probe with specific antibody (detailed western blot protocol below).


Western blot

Western blotting was used to detect the expression of proteins in the E. coli chassis. 1 ml of an overnight culture of cells were pelleted by centrifugation.
The pellets were resuspended in Laemmli buffer and boiled for 2 mins to lyse the cells. Samples were then loaded on freshly prepared 4-12 % polyacrylamide gels. Gels were run in SDS buffer at 180 V for 45-60 mins to separate proteins by size.
Proteins were transferred onto PVDF membrane by semi-dry transfer at 175 mA for 20 min for western blot analysis, following the transfer membranes were blocked in 5 % milk/TBS overnight. The target proteins contained a hemagglutinin tag for detection by monoclonal Anti-HA−Peroxidase antibodies supplied by Sigma-Aldrich. Membranes were washed in Tris-buffered saline containing 0.1 % Tween 20 and incubated with the antibody at 1:10000 concentration in TBST for 1 hour at room temperature.
Photo-detection of the cross-reacting bands used ECL reagent (luminol + HRP) and exposure on photographic film.

References

1Sambrook, J., and Russell, D. W. (2001) Molecular cloning : a laboratory manual, 3rd ed., Cold Spring Harbor Laboratory Press, Cold Spring Harbor, N.Y.