Team:Bielefeld-CeBiTec/Results/CO2-fixation/Measurement
From 2014.igem.org
Line 121: | Line 121: | ||
Equation to calculate the concentration of carbon dioxide from the output of the Qubit Analyzer<br> | Equation to calculate the concentration of carbon dioxide from the output of the Qubit Analyzer<br> | ||
x = y - 1555,34754 / 4,10739<br> | x = y - 1555,34754 / 4,10739<br> | ||
- | this needs to be estimated by the portion of exhaust gas from the reactor to quantify the amount of carbon dioxide precisely | + | this needs to be estimated by the portion of exhaust gas from the reactor to quantify the amount of carbon dioxide precisely<br> |
+ | Estimation an measurement shows the same result indicating the accuracy of the system! | ||
<br> | <br> | ||
Revision as of 03:26, 18 October 2014
Module II - Carbon Dioxide (CO2) Fixation
Cultivation
The aim of the cultivation was to characterize the carbon dioxide fixation in E. coli by an appropriate process. For this approach we wanted to establish a fermentation process, where E. coli is growing first under aeration to obtain aerobic growth conditions to determine the carbon dioxide fixation of the RuBisCo and the Carboxysome afterwrds under this condition, as well as conditions were oxygen is limited, but still aeration takes place. Besides we wanted to ensure that an effective carbon dioxide fixation would be measured. Therefore we gased in additional carbon dioxide, resulting in an 10 fold hihger atmospheric concentraction of 0,312 %. Besides there were no experience described in litarature how much carbon dioxide can be used by a hetereotrophic bacteria like E. coli. To determine even the slightest change in the carbon dioxide balance a the very sensitive Qubit Analyzer was used for the carbon dioxide fixation...
Besides the complex equilibrium of carbon dioxide (CO2) and bicarbonate (HCO3- as shwon in Figure 1 have to be considered. One aspect is that the higher concentration of carbon dioxide is inhibiting hte bacterial growth by stressing the cell to maintain the intracelluar pH value and decreasing the pH optimum of its enzymes when the cell is not able to regulate the pH anymore. A higher concentration of carbon dioxide (CO2) is archieved by excess pressure, a higher stirrer speed or lower pH value. This parameter are also optimal for an efficient oxygen supply of the cell, but the problem is that carbon dioxide is better soulable than oxygen in water so that it must be evaluate how much carbon dioxde the cell tolerate and how much oxygen is dispensble for the implemtation of the process.
Mixure of carbon dioxde and air of the exhaust gas because the Qubit analyzer is too sensitive.
Avoiding tailback by additional pump -> pulsing Figure 4
x = y - 1555,34754 / 4,10739
this needs to be estimated by the portion of exhaust gas from the reactor to quantify the amount of carbon dioxide precisely
Estimation an measurement shows the same result indicating the accuracy of the system!
After the development of the cultivation process for the measurement of carbon dioxde fiaxtion in a hetereotrophic bacteria, the process shown in Figure 7 shows the desired requirements for the quantification, as there is first a phase of full oxygen supply, which dreases in the exponentiell phase with the bacterial growth to end up in the desired oxygen limitation! With this system a quantification of the carbon dioxide fixation of a organism that is normal not able to use carbon dioxide as a substrate in quantitative amounts should be able up to now!
References
-
Sage, Rowan F. „Variation in the K(cat) of Rubisco in C(3) and C(4) Plants and Some Implications for Photosynthetic Performance at High and Low Temperature“. Journal of Experimental Botany 53, no. 369 (2002): 609–20.