Team:Hong Kong HKUST/pneumosensor/characterization
From 2014.igem.org
Line 111: | Line 111: | ||
<tr class= "content_row" valign= "top"> | <tr class= "content_row" valign= "top"> | ||
- | + | <td class= "content_cell" colspan= "2"> | |
<div class= "content_area_two_row"> | <div class= "content_area_two_row"> | ||
- | <p> <br><b>Introduction</b> <br><br> | + | <div class="content_image"> |
- | To test the functionality of σ<sup>X</sup>, we first enable constitutive expression of σ<sup>X</sup> in the σ<sup>X</sup> Generator, BBa_K1379006. The generator was then assembled with the standard promoter measurement kit BBa_E0240, with either promoter P<sub>chbB</sub> (Promoter only: BBa_K1379000, w/ BBa_E0240: BBa_K1379002) and P<sub>comFA</sub> (Promoter only: BBa_K1379001, w/ BBa_E0240: BBa_K1379003). <i>E. coli</i> colonies holding the resulting constructs in pSB3K3 were observed under fluorescent macroscope with UV filter. Measurement kit for standard reference promoter BBa_J23101, which is I20260 was used as a positive control; BBa_E0240 was used as the general negative control. for background fluorescence. Measurement kits for P<sub>chbB</sub> P<sub>comFA</sub> without σ<sup>X</sup> Generator were used as negative controls for function of σ<sup>X</sup>. | + | <img src= "https://static.igem.org/mediawiki/2014/4/43/PxhvV%26PcomFA_WIKI_copy.png"/> |
+ | <h5 style="font-size: 13px">Figure 1. P<sub>chbB</sub> and P<sub>comFA</sub> promoters activated in presence of σ<sup>X</sup>.</h5> | ||
+ | <h6 style= "font-size: 13px"> Only in the presence of σ<sup>X</sup> would P<sub>chbB</sub> and P<sub>comFA</sub> be turned on, therefore, σ<sup>X</sup> is functional. P<sub>chbB</sub> and P<sub>comFA</sub> gave little GFP signal in the absence of σ<sup>X</sup> but has comparable activity as reference promoter BBa_J23101 in presence of σ<sup>X</sup>. Scale bar = 5mm.</h6> | ||
+ | </div> | ||
+ | </div> | ||
+ | |||
+ | <p><br><b>Introduction</b> <br><br> | ||
+ | <p class="first_letter_enhanced">To test the functionality of σ<sup>X</sup>, we first enable constitutive expression of σ<sup>X</sup> in the σ<sup>X</sup> Generator, BBa_K1379006. The generator was then assembled with the standard promoter measurement kit BBa_E0240, with either promoter P<sub>chbB</sub> (Promoter only: BBa_K1379000, w/ BBa_E0240: BBa_K1379002) and P<sub>comFA</sub> (Promoter only: BBa_K1379001, w/ BBa_E0240: BBa_K1379003). <i>E. coli</i> colonies holding the resulting constructs in pSB3K3 were observed under fluorescent macroscope with UV filter. Measurement kit for standard reference promoter BBa_J23101, which is I20260 was used as a positive control; BBa_E0240 was used as the general negative control. for background fluorescence. Measurement kits for P<sub>chbB</sub> P<sub>comFA</sub> without σ<sup>X</sup> Generator were used as negative controls for function of σ<sup>X</sup>. | ||
<br> | <br> | ||
</p> | </p> | ||
- | </ | + | |
+ | </tr> | ||
</td> | </td> | ||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
</table> | </table> | ||
</div> | </div> | ||
<!--end of two row of content, image first row, text second row --> | <!--end of two row of content, image first row, text second row --> | ||
- | + | ||
<!-- one row of content , two column one picture right--> | <!-- one row of content , two column one picture right--> | ||
<div class='content_1'><h3> <a href= "http://parts.igem.org/Part:BBa_K1379000">P<sub>chbB</sub> (BBa_K1379000) </a></h3> | <div class='content_1'><h3> <a href= "http://parts.igem.org/Part:BBa_K1379000">P<sub>chbB</sub> (BBa_K1379000) </a></h3> | ||
Line 145: | Line 139: | ||
<td class= "content_cell"> | <td class= "content_cell"> | ||
<div class= "content_area_one_row"> | <div class= "content_area_one_row"> | ||
- | <p>To measure the R.P.U (Relative Promoter Unit) of P<sub>chbB</sub> promoter, we adopted the method described by Kelly et al. in “Measuring the activity of BioBrick promoters using an in vivo reference standard” (Kelly et al., 2009). By linking P<sub>chbB</sub> promoter with GFP generator (BBa_E0240), the promoter activity was represented by the GFP synthesis rate. Fluorescence was measured using EnVision multilabel reader from Perkin Elmer Company, when the cells are in the mid-log phase. OD595 values were measured and converted to OD600 to obtain the R.P.U of the promoter. The σ<sup>x</sup> gene and P<sub>chbB</sub> promoter used in the construct are both cloned from <i>E. coli</i> NCTC 7465 strain. The experimental construct used was BBa_K1379005, which contain σ<sup>x</sup> generator, P<sub>chbB</sub>, and GFP generator. The positive control used in this characterization is BBa_I20260 which is a constitutive promoter containing GFP generator, while the negative control used in this characterization is BBa_K1379002 which is P<sub>chbB</sub> promoter with GFP generator but without σ<sup>x</sup> generator.<br> </p> | + | <p class="first_letter_enhanced">To measure the R.P.U (Relative Promoter Unit) of P<sub>chbB</sub> promoter, we adopted the method described by Kelly et al. in “Measuring the activity of BioBrick promoters using an in vivo reference standard” (Kelly et al., 2009). By linking P<sub>chbB</sub> promoter with GFP generator (BBa_E0240), the promoter activity was represented by the GFP synthesis rate. Fluorescence was measured using EnVision multilabel reader from Perkin Elmer Company, when the cells are in the mid-log phase. OD595 values were measured and converted to OD600 to obtain the R.P.U of the promoter. The σ<sup>x</sup> gene and P<sub>chbB</sub> promoter used in the construct are both cloned from <i>E. coli</i> NCTC 7465 strain. The experimental construct used was BBa_K1379005, which contain σ<sup>x</sup> generator, P<sub>chbB</sub>, and GFP generator. The positive control used in this characterization is BBa_I20260 which is a constitutive promoter containing GFP generator, while the negative control used in this characterization is BBa_K1379002 which is P<sub>chbB</sub> promoter with GFP generator but without σ<sup>x</sup> generator.<br> </p> |
Line 175: | Line 169: | ||
<div class= "content_area_one_row"> | <div class= "content_area_one_row"> | ||
- | <p><u><b>Characterization Procedure</b></u><br><br> | + | <p><br><u><b>Characterization Procedure</b></u><br><br> |
- | 1. | + | 1. Constructing BBa_K1379005-pSB3K3 (σ<sup>x</sup> Generator (BBa_K1379006)-P<sub>chbB</sub>-BBa_E0240-pSB3K3) ,Transforming BBa_K1379002-pSB3K3 (P<sub>chbB</sub>-BBa_E0240-pSB3K3), Transforming BBa_I20260-pSB3K3 (Standard Constitutive Promoter/Reference Promoter) from the 2014 Distribution Kit, Transforming BBa_E0240-pSB3K3 (GFP generator) from the 2014 Distribution Kit.<br><br> |
2. Preparing supplemented M9 medium (M9 Minimal salt medium protocols could be seen on the protocols page) <br><br> | 2. Preparing supplemented M9 medium (M9 Minimal salt medium protocols could be seen on the protocols page) <br><br> | ||
Line 229: | Line 223: | ||
<td class= "content_cell"> | <td class= "content_cell"> | ||
<div class= "content_area_one_row"> | <div class= "content_area_one_row"> | ||
- | <p>The method of measuring RPU (Relative Promoter Unit) of P<sub>comFA</sub> promoter is similar to measuring RPU of P<sub>chbB</sub> which adopted the method described by Kelly et al. in “Measuring the activity of BioBrick promoters using an in vivo reference standard” (Kelly et al., 2009). There are no difference in measurement condition of measuring P<sub>comFA</sub> and P<sub>chbB</sub>. Fluorescence and absorbance are measured in the same time period. The experimental construct used was BBa_K1379007, which contain σ<sup>x</sup> generator, P<sub>comFA</sub>, and GFP generator. The positive control used in this characterization is BBa_I20260 which is a constitutive promoter containing GFP generator, while the negative control used in this characterization is BBa_K1379002 which is P<sub>comFA</sub> promoter with GFP generator but without σ<sup>x</sup> generator. </p> | + | <p class="first_letter_enhanced">The method of measuring RPU (Relative Promoter Unit) of P<sub>comFA</sub> promoter is similar to measuring RPU of P<sub>chbB</sub> which adopted the method described by Kelly et al. in “Measuring the activity of BioBrick promoters using an in vivo reference standard” (Kelly et al., 2009). There are no difference in measurement condition of measuring P<sub>comFA</sub> and P<sub>chbB</sub>. Fluorescence and absorbance are measured in the same time period. The experimental construct used was BBa_K1379007, which contain σ<sup>x</sup> generator, P<sub>comFA</sub>, and GFP generator. The positive control used in this characterization is BBa_I20260 which is a constitutive promoter containing GFP generator, while the negative control used in this characterization is BBa_K1379002 which is P<sub>comFA</sub> promoter with GFP generator but without σ<sup>x</sup> generator. </p> |
</div> | </div> | ||
</td> | </td> | ||
Line 249: | Line 243: | ||
<div class= "content_area_one_row"> | <div class= "content_area_one_row"> | ||
- | <p><u><b>Characterization Procedure</b></u><br><br> | + | <p><br><u><b>Characterization Procedure</b></u><br><br> |
1. Constructing BBa_K1379007-pSB3K3(σ<sup>x</sup> Generator (BBa_K1379006)-P<sub>comFA</sub>-BBa_E0240-pSB3K3) ,Transforming BBa_K1379003-pSB3K3 (P<sub>comFA</sub>-BBa_E0240-pSB3K3), Transforming BBa_I20260-pSB3K3 (Standard Constitutive Promoter/Reference Promoter) from the 2014 Distribution Kit, Transforming BBa_E0240-pSB3K3 (GFP generator) from the 2014 Distribution Kit.<br><br> | 1. Constructing BBa_K1379007-pSB3K3(σ<sup>x</sup> Generator (BBa_K1379006)-P<sub>comFA</sub>-BBa_E0240-pSB3K3) ,Transforming BBa_K1379003-pSB3K3 (P<sub>comFA</sub>-BBa_E0240-pSB3K3), Transforming BBa_I20260-pSB3K3 (Standard Constitutive Promoter/Reference Promoter) from the 2014 Distribution Kit, Transforming BBa_E0240-pSB3K3 (GFP generator) from the 2014 Distribution Kit.<br><br> | ||
Revision as of 16:52, 8 October 2014
{{{1}}}
Pneumosensor Characterization
σx(BBa_K1379004)
Figure 1. PchbB and PcomFA promoters activated in presence of σX.Only in the presence of σX would PchbB and PcomFA be turned on, therefore, σX is functional. PchbB and PcomFA gave little GFP signal in the absence of σX but has comparable activity as reference promoter BBa_J23101 in presence of σX. Scale bar = 5mm.
To test the functionality of σX, we first enable constitutive expression of σX in the σX Generator, BBa_K1379006. The generator was then assembled with the standard promoter measurement kit BBa_E0240, with either promoter PchbB (Promoter only: BBa_K1379000, w/ BBa_E0240: BBa_K1379002) and PcomFA (Promoter only: BBa_K1379001, w/ BBa_E0240: BBa_K1379003). E. coli colonies holding the resulting constructs in pSB3K3 were observed under fluorescent macroscope with UV filter. Measurement kit for standard reference promoter BBa_J23101, which is I20260 was used as a positive control; BBa_E0240 was used as the general negative control. for background fluorescence. Measurement kits for PchbB PcomFA without σX Generator were used as negative controls for function of σX.
|
PchbB (BBa_K1379000)
To measure the R.P.U (Relative Promoter Unit) of PchbB promoter, we adopted the method described by Kelly et al. in “Measuring the activity of BioBrick promoters using an in vivo reference standard” (Kelly et al., 2009). By linking PchbB promoter with GFP generator (BBa_E0240), the promoter activity was represented by the GFP synthesis rate. Fluorescence was measured using EnVision multilabel reader from Perkin Elmer Company, when the cells are in the mid-log phase. OD595 values were measured and converted to OD600 to obtain the R.P.U of the promoter. The σx gene and PchbB promoter used in the construct are both cloned from E. coli NCTC 7465 strain. The experimental construct used was BBa_K1379005, which contain σx generator, PchbB, and GFP generator. The positive control used in this characterization is BBa_I20260 which is a constitutive promoter containing GFP generator, while the negative control used in this characterization is BBa_K1379002 which is PchbB promoter with GFP generator but without σx generator. |
Figure 2. PchbB promoter Relative Promoter Unit (RPU) is measured with reference to J23101 constitutive promoter.PchbB promoter induced by σx gave GFP signals. This fluorescence expression was measured over time, and divided by the OD of the cells. In the end, it was standardized based on J23101 promoter strength. Measurement was done by using 3 replicas. |
PchbB Characterization Method
|
PcomFA(BBa_K1379001)
Figure 3. PcomFA promoter Relative Promoter Unit (RPU) is measured with reference to J23101 constitutive promoter.Phelicase promoter induced by σx gave GFP signals. This fluorescence expression was measured over time, and divided by the OD of the cells. In the end, it was standardized based on J23101 promoter strength. Measurement was done by using 3 replicas. |
The method of measuring RPU (Relative Promoter Unit) of PcomFA promoter is similar to measuring RPU of PchbB which adopted the method described by Kelly et al. in “Measuring the activity of BioBrick promoters using an in vivo reference standard” (Kelly et al., 2009). There are no difference in measurement condition of measuring PcomFA and PchbB. Fluorescence and absorbance are measured in the same time period. The experimental construct used was BBa_K1379007, which contain σx generator, PcomFA, and GFP generator. The positive control used in this characterization is BBa_I20260 which is a constitutive promoter containing GFP generator, while the negative control used in this characterization is BBa_K1379002 which is PcomFA promoter with GFP generator but without σx generator. |
PcomFA Characterization Method
|
J. R. Kelly, A. J. Rubin, J. H. Davis, J. Cumbers, M. J. Czar, ..., D. Endy. (2009). Measuring the activity of BioBrick promoters using an in vivo reference standard. Journal of Biological Engineering, 3, 4. doi: 10.1186/1754-1611-3-4 |
Home |
Pneumosensor |
Riboregulator |
Human Practice |
Team |
WetLab |
Achievement |