<p style="color:#212f20;">
 +
Power:<br>
 +
Computer Interface:<br>
 +
Electrode Connector Type:<br>
 +
Microcontroller:<br>
 +
Sampling Rate:<br>
 +
Dimensions:<br><br>
 +
 +
Potential Range:<br>
 +
Potential Resolution:<br><br>
 +
 +
Current Ranges:<br>
 +
Current Resolutions:<br>
 +
Offsets at Zero:<br>
 +
Accuracies at Zero:<br>
 +
Maximum Measurable Current:<br>
 +
</p>
 +
</div>
 +
<div class="potentiostatRightTab">
 +
<p style="color:#212f20;">
 +
USB Micro-B or 5.6V-16V DC Power Supply<br>
 +
USB Micro-B<br>
 +
USB Mini-B<br>
 +
Teensy 3.1<br>
 +
3000 SPs<br>
 +
102 mm x 102 mm x 20 mm<br><br>
 +
±1 V<br>
 +
500 µV<br><br>
 +
±100 µA to ±100 nA (4 ranges)<br>
 +
25 nA to 25 pA<br>
 +
≤0.1% of current range<br>
 +
≤0.33% of current range<br>
 +
±100 µA<br>
</div>
</div>

Revision as of 03:43, 24 September 2014

UC Davis iGEM 2014

Hardware Specifications

Power:
Computer Interface:
Electrode Connector Type:
Microcontroller:
Sampling Rate:
Dimensions:

Potential Range:
Potential Resolution:

Current Ranges:
Current Resolutions:
Offsets at Zero:
Accuracies at Zero:
Maximum Measurable Current:

USB Micro-B or 5.6V-16V DC Power Supply
USB Micro-B
USB Mini-B
Teensy 3.1
3000 SPs
102 mm x 102 mm x 20 mm

±1 V
500 µV

±100 µA to ±100 nA (4 ranges)
25 nA to 25 pA
≤0.1% of current range
≤0.33% of current range
±100 µA

Software Specifications

Potentiostat:



Electrode Operation:

Software Features:




Anodic Stripping (2 wave types)
Cyclic Voltammetry
Potentiostatic Amperometry

Adjustable Quiet Time

Data Export *.CSV
Digital Signal Processing Filters
Data Analysis and Statistics
Enzyme Specificity Input
Aldehyde Prediction

Getting Started...

Power:
Computer Interface:
Electrode Connector Type:
Microcontroller:
Sampling Rate:
Dimensions:

Potential Range:
Potential Resolution:

Current Ranges:
Current Resolutions:
Offsets at Zero:
Accuracies at Zero:
Maximum Measurable Current:

USB Micro-B or 5.6V-16V DC Power Supply
USB Micro-B
USB Mini-B
Teensy 3.1
3000 SPs
102 mm x 102 mm x 20 mm

±1 V
500 µV

±100 µA to ±100 nA (4 ranges)
25 nA to 25 pA
≤0.1% of current range
≤0.33% of current range
±100 µA