<p class="first_letter_enhanced"> For characterization, P<sub>celA</sub> promoter was assembled with the promoter measurement kit <a href= "http://parts.igem.org/Part:BBa_E0240">BBa_E0240</a> to give the P<sub>celA</sub> Measurement Kit <a href= "http://parts.igem.org/Part:BBa_K1379002">BBa_K1379002</a> in plasmid pSB3K3. The construct was further assembled with σ<sup>X</sup> generator <a href= "http://parts.igem.org/Part:BBa_K1379006">BBa_K1379006</a> to give <a href= "http://parts.igem.org/Part:BBa_K1379005">BBa_K1379005</a>. <br><br> | <p class="first_letter_enhanced"> For characterization, P<sub>celA</sub> promoter was assembled with the promoter measurement kit <a href= "http://parts.igem.org/Part:BBa_E0240">BBa_E0240</a> to give the P<sub>celA</sub> Measurement Kit <a href= "http://parts.igem.org/Part:BBa_K1379002">BBa_K1379002</a> in plasmid pSB3K3. The construct was further assembled with σ<sup>X</sup> generator <a href= "http://parts.igem.org/Part:BBa_K1379006">BBa_K1379006</a> to give <a href= "http://parts.igem.org/Part:BBa_K1379005">BBa_K1379005</a>. <br><br> | ||
Line 58: | Line 59: | ||
Quantitative characterization was performed following the protocol described in “Measuring the activity of BioBrick promoters using an in vivo reference standard” (Kelly et al., 2009). <i>E. coli</i> DH10B strains holding the constructs with or without σ<sup>X</sup> generator respectively were grown to mid-log phases. GFP intensities and cell densities were then sampled every 30 minutes for 5 consecutive time points to obtain growth rates and GFP synthesis rates. The GFP synthesis rates were then compared to that of standard reference promoter <a href= "http://parts.igem.org/Part:BBa_J23101">BBa_J23101</a> measurement device <a href= "http://parts.igem.org/Part:BBa_I20260">BBa_I20260</a> to obtain the Relative Promoter Units (RPUs). For subtraction of background fluorescence, pSB3K3 holding <a href= "http://parts.igem.org/Part:BBa_E0240">BBa_E0240</a> was measured alongside. The measurement was done with 3 replicas. | Quantitative characterization was performed following the protocol described in “Measuring the activity of BioBrick promoters using an in vivo reference standard” (Kelly et al., 2009). <i>E. coli</i> DH10B strains holding the constructs with or without σ<sup>X</sup> generator respectively were grown to mid-log phases. GFP intensities and cell densities were then sampled every 30 minutes for 5 consecutive time points to obtain growth rates and GFP synthesis rates. The GFP synthesis rates were then compared to that of standard reference promoter <a href= "http://parts.igem.org/Part:BBa_J23101">BBa_J23101</a> measurement device <a href= "http://parts.igem.org/Part:BBa_I20260">BBa_I20260</a> to obtain the Relative Promoter Units (RPUs). For subtraction of background fluorescence, pSB3K3 holding <a href= "http://parts.igem.org/Part:BBa_E0240">BBa_E0240</a> was measured alongside. The measurement was done with 3 replicas. | ||
- | |||
- | |||
</div> | </div> | ||
- | |||
- | |||
<div class= "content_area_one_row"> | <div class= "content_area_one_row"> |
Revision as of 15:53, 17 October 2014
Pneumosensor Characterization
σx(BBa_K1379004)
To test the functionality of σX, we first enable constitutive expression of σX in the σX Generator, BBa_K1379006.The generator was then assembled with the standard promoter measurement kit BBa_E0240, with either promoter PcelA (Promoter only: BBa_K1379000, w/ BBa_E0240: BBa_K1379002) and PcomFA (Promoter only: BBa_K1379001, w/ BBa_E0240: BBa_K1379003). E. coli colonies holding the resulting constructs in pSB3K3 were observed under fluorescent macroscope with UV filter. Measurement kit for standard reference promoter BBa_J23101, which is BBa_I20260 was used as a positive control; BBa_E0240 was used as the general negative control. for background fluorescence. Measurement kits for PcelA PcomFA without σX Generator were used as negative controls for function of σX.
Figure 1. PcelA and PcomFA promoters activated in presence of σX.Only in the presence of σX would PcelA and PcomFA be turned on, as GFP expression could be seen when σX present. Therefore, σX is functional. PcelA and PcomFA gave little GFP signal in the absence of σX but has comparable activity as reference promoter BBa_J23101 in presence of σX. Scale bar = 5mm. |
PcelA (BBa_K1379000) and PcomFA (BBa_K1379001)
For characterization, PcelA promoter was assembled with the promoter measurement kit BBa_E0240 to give the PcelA Measurement Kit BBa_K1379002 in plasmid pSB3K3. The construct was further assembled with σX generator BBa_K1379006 to give BBa_K1379005. Figure 2. PcelA has 0.53 RPU and PcomFA hsa 1.21 RPU when paired with σX generator.PcelA and PcomFA was measured in reference to BBa_J23101 constitutive promoter with and without σX generator BBa_K1379006. RPU shown was calculated from 3 replicas. |
Characterization Method
Construction Measurement
|
BioCyc was retrieved from http://www.biocyc.org/SPNE171101/NEW-IMAGE?type=GENE&object=GJC8-867 and http://www.biocyc.org/SPNE171101/NEW-IMAGE?type=GENE&object=GJC8-867
|