Team:Aachen/Project/Measurement Device
From 2014.igem.org
Line 107: | Line 107: | ||
|- | |- | ||
| [[File:Aachen_Device_1.jpg|300px]] || Start building your own ''WatsOn'' by assembling the base plate, the sides and the interior wall. | | [[File:Aachen_Device_1.jpg|300px]] || Start building your own ''WatsOn'' by assembling the base plate, the sides and the interior wall. | ||
- | |- | + | |-style="border-top: 2px #808080 solid;" |
| [[File:Aachen_Device_2_3.jpg|350px] [File:Aachen_Device_.3jpg|300px]] || Fix the Peltier heater on the back of the aluminum block and place it in the hole of the interior wall.<html><br/></html>Arrange the 4x4 450nm LEDs and the 2x3 480nm LEDs | | [[File:Aachen_Device_2_3.jpg|350px] [File:Aachen_Device_.3jpg|300px]] || Fix the Peltier heater on the back of the aluminum block and place it in the hole of the interior wall.<html><br/></html>Arrange the 4x4 450nm LEDs and the 2x3 480nm LEDs | ||
- | |- | + | |-style="border-top: 2px #808080 solid;" |
| [[File:Aachen_Device_7.jpg|350px]] || Assemble the camera holder with the camera and the corresponding filter slide on the lower part. Over the camera you can place the temperature sensor for measuring the indoor temperature. Finally put the fan on the back of the camera holder. | | [[File:Aachen_Device_7.jpg|350px]] || Assemble the camera holder with the camera and the corresponding filter slide on the lower part. Over the camera you can place the temperature sensor for measuring the indoor temperature. Finally put the fan on the back of the camera holder. | ||
- | |- | + | |-style="border-top: 2px #808080 solid;" |
| [[File:Aachen_Device_8.jpg|350px]] || Connect the electronic components on the outside and the inside according to the wiring diagramm. | | [[File:Aachen_Device_8.jpg|350px]] || Connect the electronic components on the outside and the inside according to the wiring diagramm. | ||
- | |- | + | |-style="border-top: 2px #808080 solid;" |
| [[File:Aachen_Device_4.jpg|350px]] || Put together the drawer. | | [[File:Aachen_Device_4.jpg|350px]] || Put together the drawer. | ||
- | |- | + | |-style="border-top: 2px #808080 solid;" |
| [[File:Aachen_Device_9.jpg|350px]] || Position the front panel and insert the drawer. | | [[File:Aachen_Device_9.jpg|350px]] || Position the front panel and insert the drawer. | ||
- | |- | + | |-style="border-top: 2px #808080 solid;" |
| [[File:Aachen_Device_10.jpg|350px]] || Place the temperature sensor for the aluminium block temperature directly on the block and put the back panel in front of it. | | [[File:Aachen_Device_10.jpg|350px]] || Place the temperature sensor for the aluminium block temperature directly on the block and put the back panel in front of it. | ||
- | |- | + | |-style="border-top: 2px #808080 solid;" |
| [[File:Aachen_Device_6.jpg|350px]] || Setup the power supply and connect all devices to either 5V or 12V. | | [[File:Aachen_Device_6.jpg|350px]] || Setup the power supply and connect all devices to either 5V or 12V. | ||
|-style="border-top: 2px #808080 solid;" | |-style="border-top: 2px #808080 solid;" |
Revision as of 16:34, 14 October 2014
|
|
|
|
|
|