Team:CSU Fort Collins/Notebook/Protocols=Gel
From 2014.igem.org
(Difference between revisions)
Line 651: | Line 651: | ||
<ul> | <ul> | ||
<li><a href="/Team:CSU_Fort_Collins/Notebook/HVP/Jun"><span>June</span></a></li> | <li><a href="/Team:CSU_Fort_Collins/Notebook/HVP/Jun"><span>June</span></a></li> | ||
- | + | <li class='last'><a href="/Team:CSU_Fort_Collins/Notebook/HVP/Jul"><span>July</span></a></li> | |
- | + | ||
- | <li class='last'><a href="/Team:CSU_Fort_Collins/Notebook/HVP/ | + | |
</ul> | </ul> | ||
</li> | </li> | ||
Line 666: | Line 664: | ||
</ul> | </ul> | ||
</li> | </li> | ||
- | <li class='has-sub'><a href='/Team:CSU_Fort_Collins/ | + | <li class='has-sub'><a href='/Team:CSU_Fort_Collins/Collab/'><span>Human Practices</span></a> |
<ul> | <ul> | ||
<li><a href='/Team:CSU_Fort_Collins/Collab/'><span>Collaboration</span></a></li> | <li><a href='/Team:CSU_Fort_Collins/Collab/'><span>Collaboration</span></a></li> | ||
Line 672: | Line 670: | ||
</ul> | </ul> | ||
</li> | </li> | ||
- | <li class='has-sub'><a href='/Team:CSU_Fort_Collins/ | + | <li class='has-sub'><a href='/Team:CSU_Fort_Collins/Parts/'><span>Achievements</span></a> |
<ul> | <ul> | ||
<li><a href='/Team:CSU_Fort_Collins/Parts/'><span>Parts</span></a></li> | <li><a href='/Team:CSU_Fort_Collins/Parts/'><span>Parts</span></a></li> | ||
Line 681: | Line 679: | ||
</ul> | </ul> | ||
</div> | </div> | ||
+ | |||
<div class="clear"></div> | <div class="clear"></div> |
Latest revision as of 17:50, 17 October 2014
Gel Electrophoresis Protocol
Show Table of Contents
- Using a balance, mass out 1.0 gram of agarose. Mix this with 100 mL of TAE 1X Buffer.
- Microwave the mixture, mixing intermittently, until all the agarose is dissolved and the mixture is homogeneous.
- Pour the mixture into a gel plate and insert an 8-lane comb. Allow to cool and solidify in the fridge or on the benchtop
- Mix your samples to run in the gel. Use 10 μL of the DNA Ladder combined with 2 μL SYBR Green in the first lane and for all samples, mix 5 μL of sample with 5 μL of nuclease-free water and 2 μL of SYBR Green/Dye Mixture.
- Place gel in tray into the gel electrophoresis apparatus; Wells should be located towards the negative (conventionally black) end. Fill apparatus with 1X TAE until the gel is completely submerged. Do not overfill.
- Load 10 μL of each sample into the appropriate wells.
- Connect wiring and run gel electrophoresis for 1 hour.
- Analyze gel in UV light and see if samples match the expected size using the ladder as a guide.