Team:Aachen/Notebook/Protocols/Analytical methods
From 2014.igem.org
(→Sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE)) |
(→Sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE)) |
||
(4 intermediate revisions not shown) | |||
Line 54: | Line 54: | ||
# run at 100 V for 35 minutes for a full gel | # run at 100 V for 35 minutes for a full gel | ||
- | == Sodium | + | == Sodium Dodecyl Sulfate Polyacrylamide Gel Electrophoresis (SDS-PAGE) == |
The SDS-PAGE is used to determine certain features of the cells' proteome such as the strength of expression of a desired protein. | The SDS-PAGE is used to determine certain features of the cells' proteome such as the strength of expression of a desired protein. | ||
Line 121: | Line 121: | ||
== Measurement of Fluorescence == | == Measurement of Fluorescence == | ||
- | The measurement of fluorescence was performed using the Synergy Mx (BioTek) | + | The measurement of fluorescence was performed using the Synergy Mx Microplate Reader (BioTek) and the corresponding Gen5 2.01 software. Unless stated otherwise following parameters were used: |
- | + | ||
* volume of sample in each well: 100 µl | * volume of sample in each well: 100 µl | ||
- | * | + | * measurement of GFP/eGFP/sfGFP |
+ | ** excitation wavelength: 496 ± 9 nm | ||
+ | ** emission wavelength: 516 ± 9 nm | ||
+ | * measurement of iLOV | ||
+ | ** excitation wavelength: 450 ± 9 nm | ||
+ | ** emission wavelength: 495 ± 9 nm | ||
+ | The fluorescence is given out in arbitrary units (a.u.). | ||
== Measurement of Optical Density == | == Measurement of Optical Density == | ||
- | Depending on the number of samples, two different devices were used for measurement of OD, the Unico Spectrophotometer 1201 (Fisher Bioblock Scientific) and the Synergy Mx (BioTek) | + | Depending on the number of samples, two different devices were used for measurement of OD, the Unico Spectrophotometer 1201 (Fisher Bioblock Scientific) and the Synergy Mx Microplate Reader (BioTek) with the corresponding Gen5 2.01 software. |
+ | |||
+ | Unless stated otherwise following parameters were used for the plate reader measurements: | ||
+ | * volume of sample in each well: 100 µl | ||
+ | * OD<sub>600</sub> with ''pathlength correction'' (including the height of liquid into the calculation of the optical density) | ||
+ | |||
+ | The respective culture medium was used as reference. | ||
Latest revision as of 03:42, 18 October 2014
|