Team:UCL/FAQ/MicroF
From 2014.igem.org
(37 intermediate revisions not shown) | |||
Line 14: | Line 14: | ||
<ul class="tabs"> | <ul class="tabs"> | ||
<li><a href="#view1">Basics</a></li> | <li><a href="#view1">Basics</a></li> | ||
- | <li><a href="#view2"> | + | <li><a href="#view2">Our Project</a></li> |
<li><a href="#view3">Design</a></li> | <li><a href="#view3">Design</a></li> | ||
</ul> | </ul> | ||
<div class="tabcontents"> | <div class="tabcontents"> | ||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
+ | <!--- This is the first section ---> | ||
+ | <div id="view1"> | ||
- | |||
- | |||
<div class="textTitle"><h4>What is Microfluidics?</h4></div> | <div class="textTitle"><h4>What is Microfluidics?</h4></div> | ||
<!-- This is the main text. Anything in a <p>TEXT</p> is a paragraph and will be spaced appropriately--> | <!-- This is the main text. Anything in a <p>TEXT</p> is a paragraph and will be spaced appropriately--> | ||
- | <p>Microfluidics is the study, design, and fabrication of devices that can handle and process fluids on the microlitre scale. Over the past few decades, this field has been responsible for many commonly used, and sometimes life-dependant, tools that people rely on. For example, glucose sensors for diabetics, is one of the plethora of handheld devices made available through microfluidics. The tiny volumes involved allow niche environments to be studied (e.g. in understanding stem cells), as well as permitting the development of high throughput screening devices (e.g. in drug discovery and development). </p><br | + | <p><img src="https://static.igem.org/mediawiki/2014/a/ad/UCLReynoldsDiagram.gif" align="right">Microfluidics is the study, design, and fabrication of devices that can handle and process fluids on the microlitre scale. Over the past few decades, this field has been responsible for many commonly used, and sometimes life-dependant, tools that people rely on. For example, glucose sensors for diabetics, is one of the plethora of handheld devices made available through microfluidics. The tiny volumes involved allow niche environments to be studied (e.g. in understanding stem cells), as well as permitting the development of high throughput screening devices (e.g. in drug discovery and development).</p><br> |
- | + | ||
- | + | ||
<!-- a <br> tag by itself creates a one line space between paragraphs --> | <!-- a <br> tag by itself creates a one line space between paragraphs --> | ||
<!-- an <a href="url of link">TEXT</a> turns the text into a link to the url you put in --> | <!-- an <a href="url of link">TEXT</a> turns the text into a link to the url you put in --> | ||
<p>One of the major hurdles in microfluidics is the fact that fluids are very difficult to mix at small volumes as a result of low <a href="http://en.wikipedia.org/wiki/Reynolds_number">Reynolds numbers</a>. Reynolds number describes flow patterns in various flow situations; a low Reynolds number indicates laminar flow, whereas a large Reynolds number indicates turbulent flow. Turbulent flow allows highly effective mixing in comparison to laminar flow. However, in microfluidics several device designs are available, which (to a greater or lesser degree) allow sufficient mixing. The flip side of this is that diffusion is often the only method of mixing. This in itself can be very useful, particularly when investigating enzyme kinetics. </p><br> | <p>One of the major hurdles in microfluidics is the fact that fluids are very difficult to mix at small volumes as a result of low <a href="http://en.wikipedia.org/wiki/Reynolds_number">Reynolds numbers</a>. Reynolds number describes flow patterns in various flow situations; a low Reynolds number indicates laminar flow, whereas a large Reynolds number indicates turbulent flow. Turbulent flow allows highly effective mixing in comparison to laminar flow. However, in microfluidics several device designs are available, which (to a greater or lesser degree) allow sufficient mixing. The flip side of this is that diffusion is often the only method of mixing. This in itself can be very useful, particularly when investigating enzyme kinetics. </p><br> | ||
+ | <!-- div is a divisor tag that just separates content. This class makes the paragraph in it black--> | ||
+ | <div class="SCJMFHIGHLIGHT"> | ||
+ | <p><img src="https://static.igem.org/mediawiki/2014/2/22/UCLDAVEJACKSONMF.jpg" align="right" width="20%">The scope and applications of microfluidics is truly immense and as time goes on, ever increasing amounts of investment is made. With more start-up companies and takeover bids in play, it is clear microfluidics is an exciting and emerging scientific field. As a powerful biological research tool, microfluidics allows the adaptation of various molecular biology techniques - ranging from on-chip gene synthesis (protein expression from coding DNA) to the screening of protein interactions. <br><br>Here's a picture of Dave Jackson "working hard" in the microfluidics lab.</p></div> | ||
- | |||
- | |||
</div> | </div> | ||
- | + | <!--- This is the second section ---> | |
+ | <div id="view2"> | ||
+ | |||
+ | <div class="textTitle"><h4>Why Microfluidics?</h4></div> | ||
+ | <!-- This is the main text. Anything in a <p>TEXT</p> is a paragraph and will be spaced appropriately--> | ||
+ | <p>Since our project involves designing a novel <a href="https://2014.igem.org/Team:UCL/Science/Bioprocessing">bioprocess</a> using whole-cell biocatalysts, microfluidics presents us with a unique and extremely useful advantage. When it comes to identifying, developing and optimising reactor designs and reaction constraints, this can be performed with ease and with low reagent cost as all variables are scaled down to a micro-level. Most importantly, the scale-down can be carried out without losing any of the accuracy or quantification of data output; this is due the number of sensors and control mechanisms which can be integrated into the microfluidic system.</p><br> | ||
+ | <!---TABLE START---> | ||
+ | <table style="width:100%"><col width="60%"><col width="40%"><tr><td> | ||
<!-- This is the video. Change the align attribute to left to move the video to the left--> | <!-- This is the video. Change the align attribute to left to move the video to the left--> | ||
<div class="video-wrapper"> | <div class="video-wrapper"> | ||
- | <iframe width="600" height="380" style="padding:0.5%; border:0.5% #000;" src="//www.youtube.com/embed/0OlMfq5WT6k" frameborder="0" allowfullscreen align="left"></iframe> | + | <iframe width="600" height="380" style="padding:0.5%; border:0.5% #000;" src="//www.youtube.com/embed/0OlMfq5WT6k" frameborder="0" allowfullscreen align="left"></iframe></div></td><td> |
- | </div> | + | |
- | + | ||
<!-- This is the video. Change the align attribute to left to move the video to the left--> | <!-- This is the video. Change the align attribute to left to move the video to the left--> | ||
<div class="video-wrapper"> | <div class="video-wrapper"> | ||
- | <iframe width="600" height="380" style="padding:0.5%; border:0.5% #000;" src="//www.youtube.com/embed/buf--n4dcUs" frameborder="0" allowfullscreen align="right"></iframe> | + | <iframe width="600" height="380" style="padding:0.5%; border:0.5% #000;" src="//www.youtube.com/embed/buf--n4dcUs" frameborder="0" allowfullscreen align="right"></iframe></div></td></tr></table> |
- | </div> | + | <!---TABLE END---> |
- | < | + | <br><!-- div is a divisor tag that just separates content. This class makes the paragraph in it black--> |
- | < | + | <div class="SCJMFHIGHLIGHT"> |
- | + | <p> | |
<img src="https://static.igem.org/mediawiki/2014/4/49/Microfluidic_set-up_iGEM.JPG" width=35% style="float:right;margin:0 0 0 10px;"> | <img src="https://static.igem.org/mediawiki/2014/4/49/Microfluidic_set-up_iGEM.JPG" width=35% style="float:right;margin:0 0 0 10px;"> | ||
The videos above were recorded in the UCL ACBE Microfluidics labs by members of our team. The video on the left is a demonstration of laminar flow across a T-junction microfluidic device. The video on the right demonstrates one of the methods of mixing made possible by microfluidics (herring bone channels etched into the chip). | The videos above were recorded in the UCL ACBE Microfluidics labs by members of our team. The video on the left is a demonstration of laminar flow across a T-junction microfluidic device. The video on the right demonstrates one of the methods of mixing made possible by microfluidics (herring bone channels etched into the chip). | ||
- | <br><br> | + | <br><br>The image on the right displays the microfluidics set-up used by our iGEM team. This device and equipment is provided for by the UCL microfluidics lab.</p></div> |
- | + | ||
- | </p> | + | |
</div> | </div> | ||
- | < | + | <!--- This is the third section ---> |
- | + | <div id="view3"> | |
- | + | ||
- | + | ||
- | + | ||
- | + | ||
- | + | ||
- | <div | + | |
- | + | ||
+ | <div class="textTitle"><h4>Our Design Process</h4></div> | ||
+ | <!-- This is the main text. Anything in a <p>TEXT</p> is a paragraph and will be spaced appropriately--> | ||
+ | <div class="video-wrapper"> | ||
+ | <iframe width="600" height="380" style="padding:1%; border:0.5% #000;" src="//www.youtube.com/embed/6UNpqpMS5vA" frameborder="0" allowfullscreen align="right"></iframe></div> | ||
+ | <p>We will use rapid polymer prototyping techniques to generate microfluidic bioreactors which will be used to test our reaction on a microscale. These microfluidic bioreactors will aid in the construction of a realistic bioprocess, which can be successfully scaled-up for industrial use. As we optimise and change our bioprocess, we can also quickly design new microfluidic chips that can mimic its development on a micro-scale. For example, it is our goal to integrate multiple downstream steps, such as chromatography, in order to isolate potential useful products. Demonstrating this in a microfluidic system is less time-consuming and far more cost effective than doing so at a larger scale.</p><br> | ||
+ | <p>For our microfluidic bioreactor, we will be using a magnetic free floating bar as our mixing system. This is an effective method of mixing at a microfluidic scale, as demonstrated in the video on the right. This video is of a microfluidic chemostat bioreactor designed by Davies et al. 2013 UCL, using a free-floating bar to mix two dyes.</p><br> | ||
+ | <div class="SCJMFHIGHLIGHT"><p> | ||
<img src="https://static.igem.org/mediawiki/2014/thumb/b/b8/AutoCAD_Device.png/800px-AutoCAD_Device.png" width=32%> | <img src="https://static.igem.org/mediawiki/2014/thumb/b/b8/AutoCAD_Device.png/800px-AutoCAD_Device.png" width=32%> | ||
<img src="https://static.igem.org/mediawiki/2014/thumb/7/71/MicrofluidicsDevice.jpg/800px-MicrofluidicsDevice.jpg" width=32% style="PADDING-LEFT: 2%" "PADDING-RIGHT: 3%"> | <img src="https://static.igem.org/mediawiki/2014/thumb/7/71/MicrofluidicsDevice.jpg/800px-MicrofluidicsDevice.jpg" width=32% style="PADDING-LEFT: 2%" "PADDING-RIGHT: 3%"> | ||
- | <img src="https://static.igem.org/mediawiki/2014/1/1e/Fluidics_Chip.JPG" width=32% align="right"> | + | <img src="https://static.igem.org/mediawiki/2014/1/1e/Fluidics_Chip.JPG" width=32% align="right"><br> |
- | + | Above are some examples of the microfluidics devices developed by our team for use in the lab at the UCL ACBE. The devices are initially designed using AutoCAD (2D and 3D computer-aided design software), once the designs are finalised they can be 3D-printed using the facilities provided by the UCL Institute of Making and UCL ACBE; allowing our bioprocess and laboratory team to experiment and improve designs.</p></div> | |
<br> | <br> | ||
- | + | <p><img src="https://static.igem.org/mediawiki/2014/4/4c/UCLAc-2014-logo.png" align="right" width="10%"> | |
- | An example of one of our microfluidic devices designed on AutoCAD can be downloaded <a href="https://static.igem.org/mediawiki/2014/f/fa/UCL_iGEM_2014_Microfluidics_Device_Design.dwg.zip">here</a>. This device utilises the basic concept of mixing the cells and dyes, producing a single output stream; much alike to the <a href="https://2014.igem.org/Team:UCL/Science/Bioprocessing">bioprocessing</a> concept. During the course of designing the microfluidic device, several key considerations must be taken into account: ability to withstand high pressure without leakage; materials of construction to be inert and transparent; size constraints of inlet and outlet piping; ability to accurately 3D-print the device. | + | An example of one of our microfluidic devices designed on AutoCAD can be downloaded <a href="https://static.igem.org/mediawiki/2014/f/fa/UCL_iGEM_2014_Microfluidics_Device_Design.dwg.zip">here</a>. This device utilises the basic concept of mixing the cells and dyes, producing a single output stream; much alike to the <a href="https://2014.igem.org/Team:UCL/Science/Bioprocessing">bioprocessing</a> concept. During the course of designing the microfluidic device, several key considerations must be taken into account: ability to withstand high pressure without leakage; materials of construction to be inert and transparent; size constraints of inlet and outlet piping; ability to accurately 3D-print the device.</p><br> |
- | + | ||
- | </ | + | |
- | + | ||
- | + | ||
+ | </div> | ||
+ | </div> | ||
+ | </div> | ||
+ | <!-- This is the css of the page. Dont change it unless you have consulted with Lewis or Adam about what your changing--> | ||
<style> | <style> | ||
/*=======PAGE HEADER=======*/ | /*=======PAGE HEADER=======*/ | ||
Line 131: | Line 124: | ||
margin-right:3%; | margin-right:3%; | ||
} | } | ||
+ | |||
/*=========Table Classes=============*/ | /*=========Table Classes=============*/ | ||
.table-bordered { | .table-bordered { | ||
border: 1px solid black; | border: 1px solid black; | ||
+ | } | ||
+ | |||
+ | .table, th, td { | ||
+ | border-collapse: collapse; | ||
+ | } | ||
+ | th, td { | ||
+ | padding: 5px; | ||
} | } | ||
</style> | </style> |
Latest revision as of 08:56, 1 October 2014
What is Microfluidics?
Microfluidics is the study, design, and fabrication of devices that can handle and process fluids on the microlitre scale. Over the past few decades, this field has been responsible for many commonly used, and sometimes life-dependant, tools that people rely on. For example, glucose sensors for diabetics, is one of the plethora of handheld devices made available through microfluidics. The tiny volumes involved allow niche environments to be studied (e.g. in understanding stem cells), as well as permitting the development of high throughput screening devices (e.g. in drug discovery and development).
One of the major hurdles in microfluidics is the fact that fluids are very difficult to mix at small volumes as a result of low Reynolds numbers. Reynolds number describes flow patterns in various flow situations; a low Reynolds number indicates laminar flow, whereas a large Reynolds number indicates turbulent flow. Turbulent flow allows highly effective mixing in comparison to laminar flow. However, in microfluidics several device designs are available, which (to a greater or lesser degree) allow sufficient mixing. The flip side of this is that diffusion is often the only method of mixing. This in itself can be very useful, particularly when investigating enzyme kinetics.
The scope and applications of microfluidics is truly immense and as time goes on, ever increasing amounts of investment is made. With more start-up companies and takeover bids in play, it is clear microfluidics is an exciting and emerging scientific field. As a powerful biological research tool, microfluidics allows the adaptation of various molecular biology techniques - ranging from on-chip gene synthesis (protein expression from coding DNA) to the screening of protein interactions.
Here's a picture of Dave Jackson "working hard" in the microfluidics lab.
Why Microfluidics?
Since our project involves designing a novel bioprocess using whole-cell biocatalysts, microfluidics presents us with a unique and extremely useful advantage. When it comes to identifying, developing and optimising reactor designs and reaction constraints, this can be performed with ease and with low reagent cost as all variables are scaled down to a micro-level. Most importantly, the scale-down can be carried out without losing any of the accuracy or quantification of data output; this is due the number of sensors and control mechanisms which can be integrated into the microfluidic system.
|
|
The videos above were recorded in the UCL ACBE Microfluidics labs by members of our team. The video on the left is a demonstration of laminar flow across a T-junction microfluidic device. The video on the right demonstrates one of the methods of mixing made possible by microfluidics (herring bone channels etched into the chip).
The image on the right displays the microfluidics set-up used by our iGEM team. This device and equipment is provided for by the UCL microfluidics lab.
Our Design Process
We will use rapid polymer prototyping techniques to generate microfluidic bioreactors which will be used to test our reaction on a microscale. These microfluidic bioreactors will aid in the construction of a realistic bioprocess, which can be successfully scaled-up for industrial use. As we optimise and change our bioprocess, we can also quickly design new microfluidic chips that can mimic its development on a micro-scale. For example, it is our goal to integrate multiple downstream steps, such as chromatography, in order to isolate potential useful products. Demonstrating this in a microfluidic system is less time-consuming and far more cost effective than doing so at a larger scale.
For our microfluidic bioreactor, we will be using a magnetic free floating bar as our mixing system. This is an effective method of mixing at a microfluidic scale, as demonstrated in the video on the right. This video is of a microfluidic chemostat bioreactor designed by Davies et al. 2013 UCL, using a free-floating bar to mix two dyes.
Above are some examples of the microfluidics devices developed by our team for use in the lab at the UCL ACBE. The devices are initially designed using AutoCAD (2D and 3D computer-aided design software), once the designs are finalised they can be 3D-printed using the facilities provided by the UCL Institute of Making and UCL ACBE; allowing our bioprocess and laboratory team to experiment and improve designs.
An example of one of our microfluidic devices designed on AutoCAD can be downloaded here. This device utilises the basic concept of mixing the cells and dyes, producing a single output stream; much alike to the bioprocessing concept. During the course of designing the microfluidic device, several key considerations must be taken into account: ability to withstand high pressure without leakage; materials of construction to be inert and transparent; size constraints of inlet and outlet piping; ability to accurately 3D-print the device.