PCR Product Purification Protocol
Show Table of Contents
-
- Adjust total volume of all PCR tubes to 100 μL
- Add 500 μL Binding Buffer to each tube
- Mix well
-
- Insert one High Pure filter tube into one collection tube
- Transfer solution from 1 into the filter
- Centrifuge 60 seconds at maximum speed
-
- Disconnect filter tube and discard flow-through
- Reconnect tubes
-
- Add 500 μL wash buffer to upper reservoir
- Centrifuge 60 seconds at maximum speed
-
- Discard the flow-through
- Recombine tubes
- Add 200 μL wash buffer
- Centrifuge for 60 seconds at maximum speed
-
- Discard flow-through and collection tube
- Reconnect filter tube to a clean 1.5 mL centrifuge tube
-
- Add 100 μL elution buffer
- Centrifuge for 1 minute at maximum speed
-
- The purified PCR product is now in the microcentrifuge tube