Team:Hong Kong HKUST/pneumosensor/characterization
From 2014.igem.org
Line 115: | Line 115: | ||
<p> <b>Introduction</b> <br><br> | <p> <b>Introduction</b> <br><br> | ||
- | To test the functionality of σ<sup>X</sup>, we first enable constitutive expression of σ<sup>X</sup> in the σ<sup>X</sup> Generator | + | To test the functionality of σ<sup>X</sup>, we first enable constitutive expression of σ<sup>X</sup> in the σ<sup>X</sup> Generator, BBa_K1379006. The generator was then assembled with the standard promoter measurement kit BBa_E0240, with either promoter P<sub>chbB</sub> (Promoter only: BBa_K1379000, w/ BBa_E0240: BBa_K1379002) and P<sub>comFA</sub> (Promoter only: BBa_K1379001, w/ BBa_E0240: BBa_K1379003). <i>E. coli</i> colonies holding the resulting constructs in pSB3K3 were observed under fluorescent macroscope with UV filter. |
<br> | <br> | ||
Revision as of 14:52, 8 October 2014
{{{1}}}
Pneumosensor Characterization
σx(BBa_K1379004)
Introduction |
Results Figure 1. PchbB and PcomFA promoter induced by σx drives GFP expression.PchbB and PcomFA promoter induced by σx gave GFP signals, while the same construct without σx did not give any GFP signals. Another negative control which is only GFP generator without σx and PchbB/PcomFA also did not give any GFP signals. Reference promoter J23101 + GFP is used as positive control. Scale bar = 5mm. |
PchbB (BBa_K1379000)
To measure the R.P.U (Relative Promoter Unit) of PchbB promoter, we adopted the method described by Kelly et al. in “Measuring the activity of BioBrick promoters using an in vivo reference standard” (Kelly et al., 2009). By linking PchbB promoter with GFP generator (BBa_E0240), the promoter activity was represented by the GFP synthesis rate. Fluorescence was measured using EnVision multilabel reader from Perkin Elmer Company, when the cells are in the mid-log phase. OD595 values were measured and converted to OD600 to obtain the R.P.U of the promoter. The σx gene and PchbB promoter used in the construct are both cloned from E. coli NCTC 7465 strain. The experimental construct used was BBa_K1379005, which contain σx generator, PchbB, and GFP generator. The positive control used in this characterization is BBa_I20260 which is a constitutive promoter containing GFP generator, while the negative control used in this characterization is BBa_K1379002 which is PchbB promoter with GFP generator but without σx generator.
|
Figure 2. PchbB promoter Relative Promoter Unit (RPU) is measured with reference to J23101 constitutive promoter.PchbB promoter induced by σx gave GFP signals. This fluorescence expression was measured over time, and divided by the OD of the cells. In the end, it was standardized based on J23101 promoter strength. Measurement was done by using 3 replicas.
|
PcomFA(BBa_K1379001)
Figure 3. PcomFA promoter Relative Promoter Unit (RPU) is measured with reference to J23101 constitutive promoter.Phelicase promoter induced by σx gave GFP signals. This fluorescence expression was measured over time, and divided by the OD of the cells. In the end, it was standardized based on J23101 promoter strength. Measurement was done by using 3 replicas. |
The method of measuring RPU (Relative Promoter Unit) of PcomFA promoter is similar to measuring RPU of PchbB which adopted the method described by Kelly et al. in “Measuring the activity of BioBrick promoters using an in vivo reference standard” (Kelly et al., 2009). There are no difference in measurement condition of measuring PcomFA and PchbB. Fluorescence and absorbance are measured in the same time period. The experimental construct used was BBa_K1379007, which contain σx generator, PcomFA, and GFP generator. The positive control used in this characterization is BBa_I20260 which is a constitutive promoter containing GFP generator, while the negative control used in this characterization is BBa_K1379002 which is PcomFA promoter with GFP generator but without σx generator. |
J. R. Kelly, A. J. Rubin, J. H. Davis, J. Cumbers, M. J. Czar, ..., D. Endy. (2009). Measuring the activity of BioBrick promoters using an in vivo reference standard. Journal of Biological Engineering, 3, 4. doi: 10.1186/1754-1611-3-4 |