Team:LIKA-CESAR-Brasil/ExtractionRNA
From 2014.igem.org
NOTEBOOK
Extraction of RNA
Materials needed Qiagen RNeasy mini kit
- 1) Pipette 600 µl blood in a tube of 1.5 mL.
- 2) Add 900 µl of lysis buffer, incubate for 10 minutes under stirring.
- 3) After centrifugation for 5 minutes at 14.000rpm.
- 4) Add to the pellet µl RLT buffer 600. Mix by pipetting.
- 5) Pipette the lysate directly into a column of the RNeasy mini kit, centrifuge for 2 min at maximum speed.
- 6) Add 1 volume of 70% ethanol to the homogenized lysate and mix well by pipetting. Do not centrifuge.
- 7) Add 700 µl Buffer RW1 to the RNeasy spin column. Close the lid gently and centrifuge for 15 s in ≥8000 xg (≥10,000rpm).
- 8) Add 500 µL of RPE buffer to the RNeasy spin column. Close the lid gently and centrifuge for 15 s in ≥8000 xg (≥10,000 rpm).
- 9) Add 500 µL of RPE buffer to the RNeasy spin column. Close the lid gently and centrifuge for 2 minutes at ≥8000 xg (≥10,000 rpm).
- 10) Place the RNeasy spin column in a new collection tube 1.5 ml (supplied). Add 30-50 µl RNAase free water directly onto the spin column membrane. Close the lid gently, and centrifuge for 1 min at ≥8000 xg (≥10,000 rpm) to elute the RNA.