Team:BYU Provo/Modeling

From 2014.igem.org

(Difference between revisions)
Line 92: Line 92:
<br></br>
<br></br>
-
<table border="1" align="center" style="margin-top:10px; margin-left:30px; margin-right:30px">
+
<table border="1" align="center" style="margin-top:10px; margin-left:150px; margin-right:150px">
<tr>
<tr>
       <td align="center">96-well plate</td><td align="center">1</td><td align="center">2</td><td align="center">3</td><td align="center">4</td>
       <td align="center">96-well plate</td><td align="center">1</td><td align="center">2</td><td align="center">3</td><td align="center">4</td>

Revision as of 21:56, 6 October 2014



BYU 2014 Team Modeling



Click here to edit this page!

Home Team Official Team Profile Project Parts Modeling Notebook Safety Attributions

Amylase and DispersinB Biofilm Assay (adapted from the 2013 BYU iGem Team Biofilm Assay)

This test will act as a qualitative check as to whether or not the biofilm is broken down/inhibited by the presence of amylase. Each well should be classified after the specified time limit with either no, low, medium, or high levels of biofilm. As more of the enzyme is used, we should see an inverse relationship occurring with the amount of biofilm on the wells when compared to the control wells that should see no decrease in the levels of biofilm. If this inverse relationship does occur between amount of enzyme and amount of biofilm, then we can conclude that the enzyme is causing the wastewater biofilm to be broken down/ inhibited.

Run assay in duplicate (one will run for 24 hours and the other for 72 hours). Leave at room temperature and do not shake. May need to use 10 mL glass tubes instead of 96-well plate if there are issues getting the biofilm from the samples to adhere to the walls of the wells.

Amounts of enzyme to be aliquoted are given in the table below.

Protocol: Will enzyme break down pre-existing biofilm?

  1. Aliquot approximately 50 uL of biofilm into each of the 96 wells of a 96-well plate. Cut off the tip of a 1000 uL pipette tip so that as little of the biofilm is broken up when transferring it from the sample tubes into the well plate. Allow biofilm to set in wells at room temperature for 24 hours.
  2. Aliquot specified amounts of purified enzyme into specified wells.
  3. Cover plates and let sit for specified times at room temperature.
  4. For plate one, after 24 hours have passed, invert the plate so that any supernatant will fall out of the plate leaving only biofilm adhering to the wells. Fill wells with carbohydrate-specific dye and invert plate again so that stain falls out. For plate two, repeat the procedure, but after 72 hours have passed.


96-well plate1234
A 0 uL of enzyme + 50 uL biofilm 1.5 uL of enzyme + 50 uL biofilm 12.5 uL of enzyme + 50 uL biofilm 25 uL of enzyme + 50 uL biofilm
B
C
D
E
F