Team:TU Delft-Leiden/Achievements

From 2014.igem.org

Revision as of 23:54, 17 October 2014 by Anton (Talk | contribs)

iGEM 2014 Microfluidics Track

Bronze Medal


Silver Medal

In addition to these, our team achieved the following goals that qualify us for a silver medal:


Gold Medal

In addition to the Bronze and Silver Medal requirements, our team achieved the following goals, that qualify us for a gold medal:

  • Utilizing our novel fluidic system, we have characterized the function of an existing Part. Any biological protocols performed utilizing our microfluidic system are documented. We compared biological protocols conducted on-chip against standard bench top techniques. Data collected is uploaded to the page of the part(s) used on the Registry of Standard Biological Parts via experience page/contribution system.
  • Utilizing the fluidic system, we have characterized the following new Parts:
    BBa_K1316011
    BBa_K1316012
    BBa_K1316016.
  • Our team helped another registered iGEM teams from another institution by characterizing a part and collaborated with other registered iGEM teams.
  • During the summer we addressed several ethical concerns related to our project (ie. Bringing synthetic biology outside the lab, the possibility that a microbial sensor device that detects landmines would get into the wrong hands, safety issues). To answer all these questions, we had meetings with various stakeholders. All these aspects are well documented on our Policy&Practice page

iGEM Special Prizes

Our team has additional achievements that make it eligible for the following prizes:

  • Best Model: For the conductive curli module, we wanted to know if a conductive path between two electrodes of a chip filled with curli growing E. coli arise at a certain point in time. We also wanted to make quantitative predictions about the resistance between the two electrodes of our system in time. We used a stochastic modeling approach, and considered the system at the gene, cell and colony level. At the colony levvel, we employed percolation theory in order to predict if a conductive path between the two electrodes arise at a certain point in time and to predict at which time this happens. Our application of percolation theory to describe the formation of a conductive biological network represents a novel approach that has not been used in the literature before.
  • Best Policy&Practice: By interviewing and discussing with a broad range of stakeholders, we have been able to determine the best application for our landmine detection module. Besides that, we have identified various issues concerning SynBio commercialization, such as legislature and public opinion, focused on the Netherlands, and proposed a strategy to guarantee a successful future for SynBio.
  • Best Measurement Approach: We measured the current our E.coli generated via a selfmade anaerobic bioreactor setup coupled to a potentiostat in order to be able to measure current created by modified E.coli. Subsequently, we miniaturized our potentiostat system, creating a microfluidics device (an improved version of the Dropsens).
  • Best Supporting Software: We wrote code for Labview in order to be able to perform the relevant measurements for our potentiostat setup. This code can be used by others to perform these measurements as well.


Top
facebook twitter