Introduction
"The goal of the interlab study is to obtain fluorescence data for three specific genetic devices expressing GFP from iGEM teams around the world. Can you measure fluorescence somewhere in your lab? Then this is the perfect study for you! Even if your lab or the organisms you work with mean that you can’t measure GFP from the specific devices, we want every team to be able to participate: email measurement at igem dot org and we will work out an alternative."

Devices Results Motivations
Devices

Geneious version 7.0.6 created by Biomatters. Available from ​http://www.geneious.com/​​

Device 1

BBa_I20260 (J23101-B0032-E0040-B0010-B0012) in the pSB3K3 vector.

Selection marker : Kanamycin

Promoter expected sequence : tttacagctagctcagtcctaggtattatgctagc

2012 BioBrick Kit location
  • BBa_I20260: Plate 2, Well 17F

I followed iGEM Distribution Kit instructions to extract DNA from the Biobrick Plate 2, Well 17F (2012) and then Heat Shock transformation of E.coli
For successful Kanymycin plates I prepared glycerol stock and labbeled it G.22.

Geneious version 7.0.6 created by Biomatters. Available from ​http://www.geneious.com/​​

Device 2

BBa_J23101 + BBa_E0240 (B0032-E0040-B0010-B0012), in the pSB1C3 vector.
Selection marker : Chloramphenicol
Promoter expected sequence : tttacagctagctcagtcctaggtattatgctagc

2014 Biobrick Kit locations
  • BBa_K823005 (BBa_J23101 in pSB1C3): Plate 1, Well 20K
  • BBa_E0240 (in pSB1C3): Plate 2, Well 24B

I followed iGEM Distribution Kit instructions to extract DNA from the Biobrick BBa_K823005 and BBa_E0240 and then Heat Shock transformation of E.coli
For successful Chloramphenicol plates, form single colonies I prepared liquid cultures overnight. I used 750uL of the liquid cultures for aglycerol stock . I used remaining 4,25 mL to make minipreps . I measured DNA content with the nanodrop.

Digestion analysis:

  • - 5 ug plasmid
  • - 5 ul FD Buffer
  • - 2.5 uL SpeI + 2.5 uL PstI (BBa_K823005) / 2.5 uL XbeI + 2.5 uL PstI (BBa_E0240)
  • - complete with H2O
(Final volume of 50 uL)
We made an eletrophoresis gel to check the fragments (the bands at around 876 bp for GFP and 2100 bp for the promoter + backbone)and then extract BBa_E0240 with Gel extraction kit. For the plasmid with the promoter I used a PCR purification kit. I introduced the GFP fragment to the Plasmid + backbone through ligation of the sticky ends SpeI and XbeI. Quantified DNA in two parts with nanodrop. The amount of vector:insert has been calculated with Promega calculator.
  • 5X Ligase Reaction Buffer 4 μl
  • Insert: Vector Molar Ratio 1:1, 1:3, 1:5
  • Total DNA 0.01-0.1 μg
  • T4 DNA Ligase 1 uL
  • Autoclaved distilled water to 25uL
  • Incubate at 22°C for 1h
  • 16°C overnight
I transformed the ligation product following Heat Shock transformation of E.coli. I have put a single colony into a liquid culture with the appropriate antibiotic and the next day I prepared a glycerol stock .

Geneious version 7.0.6 created by Biomatters. Available from ​http://www.geneious.com/​​

Device 3

*BBa_J23115 was cloned using BBa_K823012 and therefore should have 2 missmatched basepairs.

BBa_J23115 + BBa_E0240 (B0032-E0040-B0010-B0012), in the pSB1C3 vector.
Selection marker : Chloramphenicol
Promoter expected sequence : tttatagctagctcagtcctaggtacaatgctagc (missmatched basepairs compared to real BBa_J23115 are underlined)

2014 Biobrick Kit locations
  • BBa_K823012 (BBa_J23115 in pSB1C3): Plate 1, Well 22I
  • BBa_E0240 (in pSB1C3): Plate 2, Well 24B

In order to prepare the third device we proceed exactly in the same way as for the Device 2, except we used BBa_K823012 instead of BBa_K823005

Sequencing

We sequenced all the three devices using iGEM Verification Primers (forward). Sequences are matching expected constructs.

Mean OD600 absorbance measured over 20h. Background absorbance (LB) subtracted from the samples. Values reported in the log scale with error bars for standard deviation (7 replicates for each sample).

First Device

Promoter expected sequence : tttacagctagctcagtcctaggtattatgctagc
Sequenced device’s promoter: TTTACAGCTAGCTCAGTCCTAGGTTATTATGCTAGC
Complete sequenced device:
ATTTGTATCTTACTATAAATAGGCGTATCACGAGGCACGAAATTTCAGATAAAAAAAATCCTTAGCTTTCGCTAAGGATGATTTCTGGAATTCGCGAGCCGCTTCTAGAGATTTACAGCTAGCTCAGTCCTAGGTTATTATGCTAGCTACTAGAGTTCACACAGGAAAGTACTAGATGCGTAAAGGAGAAGAACTTTTCACTGGAGTTGTCCCAATTCTTGTTGAATTAGATGGTGATGTTAATGGGCACAAATTTTCTGTCAGTGGAGAGGGTGAAGGTGATGCAACATACGGAAAACTTACCCTTAAATTTATTTGCACTACTGGAAAACTACCTGTTCCATGGCCAACACTTGTCACTACTTTCGGTTATGGTGTTCAATGCTTTGCGAGATACCCAGATCATATGAAACAGCATGACTTTTTCAAGAGTGCCATGCCCGAAGGTTATGTACAGGAAAGAACTATATTTTTCAAAGATGACGGGAACTACAAGACACGTGCTGAAGTCAAGTTTGAAGGTGATACCCTTGTTAATAGAATCGAGTTAAAAGGTATTGATTTTAAAGAAGATGGAAACATTCTTGGACACAAATTGGAATACAACTATAACTCACACAATGTATACATCATGGCAGACAAACAAAAGAATGGAATCAAAGTTAACTTCAAAATTAGACACAACATTGAAGATGGAAGCGTTCAACTAGCAGACCATTATCAACAAAATACTCCAATTGGCGATGGCCCTGTCCTTTTACCAGACAACCATTACCTGTCCACACAATCTGCCCTTTCGAAAGATCCCAACGAAAAGAGAGACCACATGGTCCTTCTTGAGTTTGTAACAGCTGCTGGGATTACACATGGCATGGATGAACTATACAAATAATAATACTAGAGCCAGGCATCAAATAAAACGAAAGGCTCAGTCGAAAGACTGGGCCTTTCGTTTTATCTGTTGTTTGTCGGTGAACGCTCTCTACTAGAGTCACACTGGGCTCACCTTCGGGTGGGCCTTTCTGCGTTTATATACTAATAACCGGCCGCTGCAGTCCCGGCAAAAAAAGGGCAAAGGTGTCCACCA

Mean of green fluorescence for three devices and NEB turbo cells.
Background fluorescence (LB) subtracted from the samples. Values reported in the log scale with error bars for standard deviation (7 replicates for Devices 1, 2, 3 and 6 replicates for NEB).

Second Device

Promoter expected sequence : tttacagctagctcagtcctaggtattatgctagc
Sequenced device’s promoter: TTTACAGCTAGCTCAGTCCTAGGTATTATGCTAGC
Complete sequenced device:
TTTGATAACTATAAATAGGCGTATCACGAGGCAGAATTTCAGATAAAAAAAATCCTTAGCTTTCGCTAAGGATGATTTCTGGAATTCGCGGCCGCTTCTAGAGTTTACAGCTAGCTCAGTCCTAGGTATTATGCTAGCTACTAGAGTCACACAGGAAAGTACTAGATGCGTAAAGGAGAAGAACTTTTCACTGGAGTTGTCCCAATTCTTGTTGAATTAGATGGTGATGTTAATGGGCACAAATTTTCTGTCAGTGGAGAGGGTGAAGGTGATGCAACATACGGAAAACTTACCCTTAAATTTATTTGCACTACTGGAAAACTACCTGTTCCATGGCCAACACTTGTCACTACTTTCGGTTATGGTGTTCAATGCTTTGCGAGATACCCAGATCATATGAAACAGCATGACTTTTTCAAGAGTGCCATGCCCGAAGGTTATGTACAGGAAAGAACTATATTTTTCAAAGATGACGGGAACTACAAGACACGTGCTGAAGTCAAGTTTGAAGGTGATACCCTTGTTAATAGAATCGAGTTAAAAGGTATTGATTTTAAAGAAGATGGAAACATTCTTGGACACAAATTGGAATACAACTATAACTCACACAATGTATACATCATGGCAGACAAACAAAAGAATGGAATCAAAGTTAACTTCAAAATTAGACACAACATTGAAGATGGAAGCGTTCAACTAGCAGACCATTATCAACAAAATACTCCAATTGGCGATGGCCCTGTCCTTTTACCAGACAACCATTACCTGTCCACACAATCTGCCCTTTCGAAAGATCCCAACGAAAAGAGAGACCACATGGTCCTTCTTGAGTTTGTAACAGCTGCTGGGATTACACATGGCATGGATGAACTATACAAATAATAATACTAGAGCCAGGCATCAAATAAAACGAAAGGCTCAGTCGAAAGACTGGGCCTTTCGTTTTATCTGTTGTTTGTCGGTGAACGCTCTCTACTAGAGTCACACTGGCTCACCTTCGGGTGGGCCTTTCTGCGTTTATATACTAGTAGCGGCCGCTGCAGTCCGGCAAAAAAGGGCAAGGTGTCACCACCCTGCCCTTTTTCTTTAAAACCGAAAAGATTACTTCCCGTTATGCAGGCTTCCTCGCTCACTGAATCGCTGCGCTCGGTCGTTCGGCTGCGGCGAACGGTATCAGCTCACTCAAAGGCGGTAATACCGGTTATCCCAAGAAATCAGGGGATAACCCCAGGAAAAAAACTTGGGACCAAAAGGCCACCCAAAGGGCCAGGAACCGTAAAAAAGGCCCCGTTTTCTGGGGTTTTTTCCAAAAGGCTCCGGCCCCCCTGGAAAAGACTTCAAAAATTCCGCCTTCTAATCCTAAAGGTGGGAAAACCCCCAA

Mean of green fluorescence divided by optical density 600 for three devices and NEB turbo cells.
Background fluorescence (LB) subtracted from the samples. Values reported in the log scale with error bars for standard deviation (7 replicates for Devices 1, 2, 3 and 6 replicates for NEB).

Third Device

Promoter expected sequence : tttatagctagctcagtcctaggtacaatgctagc
Sequenced promoter sequence:TTTATAGCTAGCTCAGTCCTAGGTACAATGCTAGC
Complete sequence:
GACTCTGATAACTATAAATAGGCGTATCACGAGGCAGAATTTCAGATAAAAAAAATCCTTAGCTTTCGCTAAGGATGATTTCTGGAATTCGCGGCCGCTTCTAGAGTTTATAGCTAGCTCAGTCCTAGGTACAATGCTAGCTACTAGAGTCACACAGGAAAGTACTAGATGCGTAAAGGAGAAGAACTTTTCACTGGAGTTGTCCCAATTCTTGTTGAATTAGATGGTGATGTTAATGGGCACAAATTTTCTGTCAGTGGAGAGGGTGAAGGTGATGCAACATACGGAAAACTTACCCTTAAATTTATTTGCACTACTGGAAAACTACCTGTTCCATGGCCAACACTTGTCACTACTTTCGGTTATGGTGTTCAATGCTTTGCGAGATACCCAGATCATATGAAACAGCATGACTTTTTCAAGAGTGCCATGCCCGAAGGTTATGTACAGGAAAGAACTATATTTTTCAAAGATGACGGGAACTACAAGACACGTGCTGAAGTCAAGTTTGAAGGTGATACCCTTGTTAATAGAATCGAGTTAAAAGGTATTGATTTTAAAGAAGATGGAAACATTCTTGGACACAAATTGGAATACAACTATAACTCACACAATGTATACATCATGGCAGACAAACAAAAGAATGGAATCAAAGTTAACTTCAAAATTAGACACAACATTGAAGATGGAAGCGTTCAACTAGCAGACCATTATCAACAAAATACTCCAATTGGCGATGGCCCTGTCCTTTTACCAGACAACCATTACCTGTCCACACAATCTGCCCTTTCGAAAGATCCCAACGAAAAGAGAGACCACATGGTCCTTCTTGAGTTTGTAACAGCTGCTGGGATTACACATGGCATGGATGAACTATACAAATAATAATACTAGAGCCAGGCATCAAATAAAACGAAAGGCTCAGTCGAAAGACTGGGCCTTTCGTTTTATCTGTTGTTTGTCGGTGAACGCTCTCTACTAGAGTCACACTGGCTCACCTTCGGGTGGGCCTTTCTGCGTTTATATACTAGTAGCGGCCGCTGCAGTCCGGCAAAAAAGGGCAAGGTGTCACCACCCTGCCCTTTTTCTTTAAAACCGAAAAGATTACTTCGCGTTATGCAGGCTTCCTCGCTCACTGACTCGCTGCGCTCGGTCGTTCGGCTGCGGCGAGCGGTATCAGCTCACTCAAAGGCGGTAATACGGTTATCCACAGAATCCGGGGGATAACCGCAGGAAAAAACATGTGGAGCCAAAAGGCCAACCAAAAGGCCAGGAACCGTAAAAAAGGCCCCGTTTGCTGGGGTTTTTTCCCAAGGGTCCCGCCCCCCTGGAAAAAGTTCCAA

OD600 and fluorescence measure over 20h

Samples preparation: Single colonies were inoculated in 5mL LB broth with appropriate antibiotic and grown to saturation overnight (16h) at 37°C with shaking (220 rpm). Samples were diluted 100x (50um in 5 mL LB with appropriate antibiotic) and incubated for 2h at 37°C prior to measurement.

Control:
LB broth with antibiotics (chloramphenicol/kanamycin)- no fluorescence
NEB turbo without fluorescence - no fluorescence, no cells
Measurment
Greiner 96 plates were loaded with 150um of cells in LB and 30um mineral oil Cells have been diluted prior to measurement as described above. Background absorbance and fluorescence was determined from LB control.
Data from the top row were excluded due to the likely evaporation and artefacts (edge effects).