Team:TU Delft-Leiden/Project/Safety

From 2014.igem.org

Revision as of 13:17, 14 October 2014 by DucoBlanken (Talk | contribs)

Safety

Overview

The aim of this team TUDelft iGEM 2014 was to build up a novel biosensor capable of emitting an electrical output in response to a signal using the microorganism Escherichia coli. Three modules have been developed in order to facilitate an electrical output and thus electron transport (see the Project Overview ). Therefore, the following genes have been used:


Gene Origin Gene/ Gene cluster Name Short Description
Shewanella oneidensis mtrCAB

ccmAH
Transport electrons from the periplasm to the extracellular space

Required for the proper maturation and folding of proteins carrying a heme group (such as the MtrCAB proteins)
Escherichia coli csgAB Two of the genes involved in the formation of curli
Aequorea victoria eGFP Fluorescent protein
Entacmaea quadricolor mKate2 Fluorescent protein


For both molecular and characterisation work, the organism E.coli has been used. On the following table, the actual strains used have been listed:


Strain name Classification Use
DH5α ML-1 Cloning work
BL21(DE3) ML-1 Land Mine module characterisation
C43(DE3) ML-1 Extracellular Electron Transport module characterisation
ΔCsgB LSR12 ML-1 Conductive curli module characterisation


Landmine detection

The use of genetically modified organisms (GMOs) represents some risks and concerns for society. Therefore, their use and handling are strictly regulated. For the development of a Plug-and-Play biosensor based on electrical current, the TU Delft iGEM team has worked on the specific case of landmine detection. Hence, our team has been dealing with chemical components that represent a big risk for human health and for the environment. As a consequence, full awareness of the potential risks of the chemicals used for our experiments was taken, and a detailed protocol was developed to handle safely the aforementioned chemicals.


Hazardous chemicals used

Land mines are mostly based on the explosive compound 2,4,6-trinitrotoluene (2,4,6-TNT). However, these mines many times contain impurities of 2,4-dinitrotoluene (2,4-DNT) and 1,3-dinitrobenzene (1,3-DNB) which, due to their volatility, can leak out of the mine. Therefore, 2,4-DNT and 1,3-DNB are quite convenient compounds for the construction of a land mine-biosensor. These chemicals, nevertheless, require special attention to ensure a safe working environment.

2,4-DNT

2,4-DNT is classified as Toxic, Harmful and Dangerous for the environment according to EU Directives 67/548/EEC or 1999/45/EC. Of special imporance is its toxicity if swallowed, in contact with skin or if inhaled.


1,3-DNB

1,3-DNB is classified as Very Toxic and Dangerous for the environment according to EU Directives 67/548/EEC or 1999/45/EC. Of special imporance is its fatality if swallowed, in contact with skin or if inhaled. It may also cause damage to organs through prolonged or repeated exposure.


Acetonitrile

For safety reasons, it is better to work with the aforementioned chemicals in liquid solutions. Due to their hydrophobicity, 2,4-DNT and 1,3-DNB were obtained dissolved in acetonitrile. This solvent itself also needs to be handled carefully for it is Highly flammable, Harmful and Irritant according to EU Directives 67/548/EEC or 1999/45/EC.


Safety measures

These chemicals need to be always handled at the Fume Cupboard. A fume cupboard is a piece of laboratory equipment designed to limit exposure to dangerous fumes. The air inside the fume hood is either vented to the outside or else filtered and recirculated.


Additionally, solutions containing either 2,4-DNT, 1,3-DNB or acetonitrile will be handled wearing Butyl-rubber gloves of a minimum thickness of 0.3mm. For more protection, Nitrile-rubber gloves should be worn underneath.


Concerning the disposal of the chemicals, these compounds are toxic to aquatic life and dangerous for the environment. Consequently, they need to be disposed appropriately. After the tests using bacteria together with these hazardous compounds, the bacteria will be first killed by adding an antibacterial agent during the required amount of time. Afterwards, the mixture containing the dead microorganisms together with the land mine compound will be brought to the Chemical Central Waste of the university to be disposed.


And last but not the least, if some chemical is spilled on the gloves, they will be removed as soon as possible without touching the skin with the gloves. In case of emergency (eg. spills) the affected area must be covered with tissues. The room needs to be evacuated for half an hour. When leaving the room make sure you take off and dispose properly the lab coat. When returning in the room, plastic bags for biological waste need to be taken. The waste should be disposed in a chemical waste bin. The Biosafety officer needs to be contacted for reporting the situation.


Important Note

The procedure described above was thoroughly reviewed and approved by the chairman of the Safety Committee of the Applied Sciences faculty of Delft University of Technology, Jos van Winsen.


Top
facebook twitter