Team:Penn/Magnetism

From 2014.igem.org

(Difference between revisions)
Line 17: Line 17:
<div id="textbox">
<div id="textbox">
<h3 style= "text-align: left">Relationship Between OD600 and T<sub>2</sub> for AMB-1</h3>
<h3 style= "text-align: left">Relationship Between OD600 and T<sub>2</sub> for AMB-1</h3>
-
<p style = "text-align: left; text-indent:0px">We attempted to explore the magnetic properties of AMB-1 as further understanding would prove AMB-1’s value as a chassis in bioremediation and other fields. We hoped to quantify the magnetic strength of AMB-1 using spin-spin relaxation time (T<sub>2</sub> time) and relate it to the cell concentration (OD600). To do so, we used a magnetic NMR machine (the minispec mq60, Bruker) to measure the T2 decay time of cell samples. A longer T<sub>2</sub> time indicated fewer magnetic particles, and therefore weaker magnetic properties. Since the relationship between the inverse of T<sub>2</sub> and OD was linear, this data supports that each cell has roughly the same number of magnetosomes, and that a greater number of these magnetosomes can be correlated with stronger magnetic properties.
+
<p style = "text-align: left; text-indent:0px">We attempted to explore the magnetic properties of AMB-1 as further understanding would prove AMB-1’s value as a chassis in bioremediation and other fields. We hoped to quantify the magnetic strength of AMB-1 using spin-spin relaxation time (T<sub>2</sub> time) and relate it to the cell concentration (OD600). To do so, we used a magnetic NMR machine (the minispec mq60, Bruker) to measure the T<sub>2</sub> decay time of cell samples. A longer T<sub>2</sub> time indicated fewer magnetic particles, and therefore weaker magnetic properties. Since the relationship between the inverse of T<sub>2</sub> and OD was linear, this data supports that each cell has roughly the same number of magnetosomes, and that a greater number of these magnetosomes can be correlated with stronger magnetic properties.
</p>
</p>

Revision as of 01:29, 18 October 2014

University of Pennsylvania iGEM

Relationship Between OD600 and T2 for AMB-1

We attempted to explore the magnetic properties of AMB-1 as further understanding would prove AMB-1’s value as a chassis in bioremediation and other fields. We hoped to quantify the magnetic strength of AMB-1 using spin-spin relaxation time (T2 time) and relate it to the cell concentration (OD600). To do so, we used a magnetic NMR machine (the minispec mq60, Bruker) to measure the T2 decay time of cell samples. A longer T2 time indicated fewer magnetic particles, and therefore weaker magnetic properties. Since the relationship between the inverse of T2 and OD was linear, this data supports that each cell has roughly the same number of magnetosomes, and that a greater number of these magnetosomes can be correlated with stronger magnetic properties.

Achievement:

The cell concentration and magnetic strength showed a linear relationship (1/T2) =(0.002x + 0.0016) with an R2 value of 0.7161.


;