Team:BostonU/Future
From 2014.igem.org
(Difference between revisions)
Line 13: | Line 13: | ||
<table width="100%" border="0" cellspacing="15" cellpadding="0"> | <table width="100%" border="0" cellspacing="15" cellpadding="0"> | ||
<tr> | <tr> | ||
- | < | + | <td scope="col"><h2>Complete priority encoder</h2><br>We are in the process of gathering flow cytometry data for our basic parts library as a completion of Chimera Phase I and carrying out multiplexing as part of Phase II. We plan to gather data for the range of functionality of our transcriptional unit variants and begin assembling our priority encoder from its constitutive transcriptional units. Functionality of the priority encoder via flow cytometry verification will mark the completion of Phase III and the Chimera workflow.<br><br> |
<h2>Refine Chimera</h2><br>The testing of our workflow by building the priority encoder is intended to demonstrate the ability of Chimera's methodology and software tools to guide a predictive assembly of a complex genetic regulatory network. We will consider our documented difficulties in cloning, testing, and interpreting data that we encountered to refine our workflow and, most importantly, define concrete metrics that must be met at each phase of the workflow. These metrics must be adaptable to any user's target device, and must therefore allow for flexibility in their definition. For example, our version of the workflow currently specifies that we screen 10 colonies per plate if we have multiplexed 5 different basic parts to allow testing of a higher range of TU variety without excessive screening. This metric would be different for protocols that measure TU variety without multiplexing in quantity, but would still be present to ensure that an appropriate variety of gene expression is being observed.<br><br> | <h2>Refine Chimera</h2><br>The testing of our workflow by building the priority encoder is intended to demonstrate the ability of Chimera's methodology and software tools to guide a predictive assembly of a complex genetic regulatory network. We will consider our documented difficulties in cloning, testing, and interpreting data that we encountered to refine our workflow and, most importantly, define concrete metrics that must be met at each phase of the workflow. These metrics must be adaptable to any user's target device, and must therefore allow for flexibility in their definition. For example, our version of the workflow currently specifies that we screen 10 colonies per plate if we have multiplexed 5 different basic parts to allow testing of a higher range of TU variety without excessive screening. This metric would be different for protocols that measure TU variety without multiplexing in quantity, but would still be present to ensure that an appropriate variety of gene expression is being observed.<br><br> | ||
<h2>Push Chimera to the limit</h2><br>The software tools we employ have the capability of allowing for construction of regulatory networks with greater complexity that our priority encoder. We aim to use Chimera to construct a novel device with nonlinear behavior, which will involve controlled protein degradation and a more complex testing scheme. | <h2>Push Chimera to the limit</h2><br>The software tools we employ have the capability of allowing for construction of regulatory networks with greater complexity that our priority encoder. We aim to use Chimera to construct a novel device with nonlinear behavior, which will involve controlled protein degradation and a more complex testing scheme. | ||
- | </ | + | </td> |
</tr> | </tr> | ||
Revision as of 21:50, 15 October 2014
Complete priority encoderWe are in the process of gathering flow cytometry data for our basic parts library as a completion of Chimera Phase I and carrying out multiplexing as part of Phase II. We plan to gather data for the range of functionality of our transcriptional unit variants and begin assembling our priority encoder from its constitutive transcriptional units. Functionality of the priority encoder via flow cytometry verification will mark the completion of Phase III and the Chimera workflow. Refine ChimeraThe testing of our workflow by building the priority encoder is intended to demonstrate the ability of Chimera's methodology and software tools to guide a predictive assembly of a complex genetic regulatory network. We will consider our documented difficulties in cloning, testing, and interpreting data that we encountered to refine our workflow and, most importantly, define concrete metrics that must be met at each phase of the workflow. These metrics must be adaptable to any user's target device, and must therefore allow for flexibility in their definition. For example, our version of the workflow currently specifies that we screen 10 colonies per plate if we have multiplexed 5 different basic parts to allow testing of a higher range of TU variety without excessive screening. This metric would be different for protocols that measure TU variety without multiplexing in quantity, but would still be present to ensure that an appropriate variety of gene expression is being observed. Push Chimera to the limitThe software tools we employ have the capability of allowing for construction of regulatory networks with greater complexity that our priority encoder. We aim to use Chimera to construct a novel device with nonlinear behavior, which will involve controlled protein degradation and a more complex testing scheme. |