Team:Hannover/Protocols/Cloning/PCR

From 2014.igem.org

(Difference between revisions)
Line 18: Line 18:
<tr><td>0.25</td><td>10 mM µl-1 reverse oligonucleotide</td></tr>
<tr><td>0.25</td><td>10 mM µl-1 reverse oligonucleotide</td></tr>
<tr><td>0.30</td><td>GoTaq® DNA Polymerase</td></tr>
<tr><td>0.30</td><td>GoTaq® DNA Polymerase</td></tr>
-
<tr><td>0.50</td><td>10 – 100 ng template</td></tr><tr><td colspan="2">ad 20 µl H2O</td></tr></table></td><td><table colspan="2" ><tr><td><b>Cylcer Program</b></td></tr><tr><td>Step</td><td>Temperature [°C]</td><td>Time [min]</td><td>Cycle no.</td></tr><tr><td>1.</td><td>95</td><td>2.0</td><td>1</td></tr><tr><td>2.</td><td>95</td><td>0.5</td><td>35</td></tr><tr><td>3.</td><td>TA</td><td>0.5</td><td>35</td></tr>
+
<tr><td>0.50</td><td>10 – 100 ng template</td></tr><tr><td colspan="2">ad 20 µl H2O</td></tr></table></td><td><table colspan="2" ><tr><td><b>Cylcer Program</b></td></tr><tr><td>Step</td><td>Temperature [°C]</td><td>Time [min]</td><td>Cycle no.</td></tr><tr><td>1.</td><td>95</td><td>2.0</td><td>1</td></tr><tr><td>2.</td><td>95</td><td>0.5</td><td>35</td></tr><tr><td>3.</td><td>TA</td><td>0.5</td><td>35</td></tr><tr><td>4.</td><td>72</td><td>-</td><td>35</td></tr></table></td></tr></table>
-
<tr><td>4.</td><td>72</td><td>60 b/s</td><td>35</td></tr></table></td></tr></table>
+
<br><br>
<br><br>
Line 30: Line 29:
<tr><td>0.25</td><td>10 mM µl-1  reverse oligonucleotide</td></tr>
<tr><td>0.25</td><td>10 mM µl-1  reverse oligonucleotide</td></tr>
<tr><td>0.30</td><td>Phusion® High-Fidelity DNA Polymerase </td></tr>
<tr><td>0.30</td><td>Phusion® High-Fidelity DNA Polymerase </td></tr>
-
<tr><td>0.50</td><td>10 – 100 ng template</td></tr><tr><td colspan="2">ad 20 µl H2O</td></tr></table></td><td><table colspan="2" ><tr><td><b>Cylcer Program</b></td></tr><tr><td>Step</td><td>Temperature [°C]</td><td>Time [min]</td><td>Cycle no.</td></tr><tr><td>1.</td><td>98</td><td>2.0</td><td>1</td></tr><tr><td>2.</td><td>98</td><td>0.5</td><td>35</td></tr><tr><td>3.</td><td>TA</td><td>0.5</td><td>35</td></tr>
+
<tr><td>0.50</td><td>10 – 100 ng template</td></tr><tr><td colspan="2">ad 20 µl H2O</td></tr></table></td><td><table colspan="2" ><tr><td><b>Cylcer Program</b></td></tr><tr><td>Step</td><td>Temperature [°C]</td><td>Time [min]</td><td>Cycle no.</td></tr><tr><td>1.</td><td>98</td><td>2.0</td><td>1</td></tr><tr><td>2.</td><td>98</td><td>0.5</td><td>35</td></tr><tr><td>3.</td><td>TA</td><td>0.5</td><td>35</td></tr><tr><td>4.</td><td>72</td><td>-</td><td>35</td></tr></table></td></tr></table>
-
<tr><td>4.</td><td>72</td><td>60 b/s</td><td>35</td></tr></table></td></tr></table>
+
<p id="Fusszeile"><br><br><br><br><img src="https://static.igem.org/mediawiki/2014/6/6a/Hannover_20141010Fusszeile2.jpg" width="980px" style="float:right" /></p>
<p id="Fusszeile"><br><br><br><br><img src="https://static.igem.org/mediawiki/2014/6/6a/Hannover_20141010Fusszeile2.jpg" width="980px" style="float:right" /></p>
</body>
</body>
</html>
</html>

Revision as of 13:21, 15 October 2014

Protocols / Standard and Colony PCR

DNA amplification for important cloning or sequencing steps was performed by a standard PCR mix including the F-530 Phusion® High-Fidelity DNA Polymerase (Thermo Scientific). Due to its 3´-5´ exonuclease activity, it is capable of proofreading its product and thus works more accurately than the GoTaq® DNA Polymerase. Hence, the latter was used only for experiments in which a correct sequence had no importance, e.g. colony PCRs. Composition and temperature program for both, the colony and standard PCR (Table 1)are summarized Table 1 and 2 respectively. Contrary to the standard PCR, the nucleic acid template for colony PCRs was directly obtained by bacterial clones. To use them as templates, bacteria were transferred into 20 μl of H2O first and then lysed by denaturation for 10 min at 80 °C. Before usage, the boiled bacteria solution was centrifuged for a short time.

Table 1: Reaction mixes and temperature programs for colony PCR.

Volume [μl]Compounds of standard PCR
4.005 x Green GoTaq© Reaction buffer
1.0025 mM µl-1 MgCl2
1.002.5 mM µl-1 dNTPs
0.2510 mM µl-1 sense oligonucleotide
0.2510 mM µl-1 reverse oligonucleotide
0.30GoTaq® DNA Polymerase
0.5010 – 100 ng template
ad 20 µl H2O
Cylcer Program
StepTemperature [°C]Time [min]Cycle no.
1.952.01
2.950.535
3.TA0.535
4.72-35


Table 2: Reaction mixes and temperature programs for standard PCR.

Volume [μl]Compounds of standard PCR
4.005 x Phusion® HF buffer
1.002.5 mM µl-1 dNTPs
0.2510 mM µl-1 sense oligonucleotide
0.2510 mM µl-1 reverse oligonucleotide
0.30Phusion® High-Fidelity DNA Polymerase
0.5010 – 100 ng template
ad 20 µl H2O
Cylcer Program
StepTemperature [°C]Time [min]Cycle no.
1.982.01
2.980.535
3.TA0.535
4.72-35