Team:Cambridge-JIC/Dry Work
From 2014.igem.org
(Difference between revisions)
(2 intermediate revisions not shown) | |||
Line 1: | Line 1: | ||
- | {{:Team:Cambridge-JIC/Templates/ | + | {{:Team:Cambridge-JIC/Templates/header_prototype2}} |
<html> | <html> | ||
+ | |||
+ | <div align="center"><a href="https://2014.igem.org/wiki/index.php?title=Team:Cambridge-JIC/Dry_Work&action=edit">Edit this page</a></div> | ||
<h3>Constructs</h3> | <h3>Constructs</h3> | ||
Line 21: | Line 23: | ||
<li>Primers are '''cheap'''. If it's too much effort to reuse primers with your new construct, just order new ones. Spend some, but not a lot, of time if you're thinking of reusing primers to try and save a bit of dollar. </li> | <li>Primers are '''cheap'''. If it's too much effort to reuse primers with your new construct, just order new ones. Spend some, but not a lot, of time if you're thinking of reusing primers to try and save a bit of dollar. </li> | ||
- | <li>Try and make your primers reusable, if they're for a reusable part. Don't just split up your construct in any which way for Gibson. </li> | + | <li>Try and make your primers reusable, if they're for a reusable part. Don't just split up your construct in any-which-way for Gibson. </li> |
Latest revision as of 16:28, 29 July 2014
Constructs
- Delete 5'-UTRs (if in doubt). 5'-UTR's affect expression rates, so if we're comparing promoters/inputs, UTR's will make a big difference. So, for the sake of normalisation, get rid of the 5'-UTRs.
- If it works, don't change it. Don't go altering spacing in between parts when making constructs!
Primers, Gibson flaps and splitting up constructs
- With our hi-tec polymerase, each fragment you're PCR'ing up can be up to 5.5kb (reliably). Any more, see if you can re-jig primers to get smaller fragments. i.e. 6kb - 2kb-2kb is not ideal, but 3kb - 4kb - 3kb is fine (or even 5kb-5kb)
- If you're splitting up your constructs, you don't need to add flaps - just choose primers appropriately!
- Make the primers. Don't really worry about secondary structures unless it's obvious. Use a melting temperature of >58 degrees.
- Check that they're correct by searching in the plasmid you're PCR'ing off and the destination construct. Make sure the primer can only prime to 1 place! (e.g. be careful using a nosT/35s region as these are very common)
- Primers are '''cheap'''. If it's too much effort to reuse primers with your new construct, just order new ones. Spend some, but not a lot, of time if you're thinking of reusing primers to try and save a bit of dollar.
- Try and make your primers reusable, if they're for a reusable part. Don't just split up your construct in any-which-way for Gibson.