Team:Hannover/Protocols/Detection/Confocal

From 2014.igem.org

(Difference between revisions)
 
(23 intermediate revisions not shown)
Line 5: Line 5:
<html>
<html>
<body>
<body>
-
<div id='main_content'>
+
<h1><a href="https://2014.igem.org/Team:Hannover/Protocols">Protocols</a> / Confocal Microscopy</h1>
-
<h1><a href="https://2014.igem.org/Team:Hannover/Protocols" target="_blank">Protocols</a> / How To: Confocal Microscopy</h1>
+
<table colspan="2"><tr><td><h4>Material:</h4></td>
<table colspan="2"><tr><td><h4>Material:</h4></td>
<tr><td>Prepared MS Samples</td><td></td></tr>
<tr><td>Prepared MS Samples</td><td></td></tr>
-
<tr><td>Confocal Microscope</td><td>(here:Eclipse TE2000-E, Nikon, Japan)</td></tr></table>
+
<tr><td>Confocal Microscope</td><td>(here: Eclipse TE2000-E, Nikon, Japan)</td></tr>
-
 
+
<tr><td></td><td><b><u>Settings</u></b><br><p><ol><li>100 x magnification<li>For penetration of fluorescence the laser wavelength were adjusted to λ= 408 nm and λ= 488 nm <br><li>Transmission microscopy: halogen lamp <u>vs.</u> Detection of GFP signals: mercury lamp</li></ol></td></tr></table>
-
 
+
-
<h2>Settings</h2><p class="text"><ol><li></ol></p>
+
<br><br>
<br><br>
<h2>Protocol</h2>
<h2>Protocol</h2>
-
<p class="text">The exponential megaprimer PCR (EMP)</p>
+
<p class="text">Before samples are screened by powerful lasers, which could bleach the GFP signal, the halogen transmission light was used for browsing the sample. After the right sample layer was focused, the source of lightening was switched to the lasers (mercury) and the pinhole-value needed to be adjusted. Three pictures were taken: one in the green channel, one in the red channel and one of in pseudo-transmission light. GFP molecules gave a green signal, while the chlorophyll visualized the chloroplasts as red dots. In order to compare the pictures, a scale bar was added in the pictures.</p
 +
<br>
<p id="Fusszeile"><br><br><br><br><img src="https://static.igem.org/mediawiki/2014/6/6a/Hannover_20141010Fusszeile2.jpg" width="980px" style="float:right" /></p>
<p id="Fusszeile"><br><br><br><br><img src="https://static.igem.org/mediawiki/2014/6/6a/Hannover_20141010Fusszeile2.jpg" width="980px" style="float:right" /></p>
</body>
</body>
</html>
</html>

Latest revision as of 23:38, 17 October 2014

Protocols / Confocal Microscopy

Material:

Prepared MS Samples
Confocal Microscope(here: Eclipse TE2000-E, Nikon, Japan)
Settings

  1. 100 x magnification
  2. For penetration of fluorescence the laser wavelength were adjusted to λ= 408 nm and λ= 488 nm
  3. Transmission microscopy: halogen lamp vs. Detection of GFP signals: mercury lamp


Protocol

Before samples are screened by powerful lasers, which could bleach the GFP signal, the halogen transmission light was used for browsing the sample. After the right sample layer was focused, the source of lightening was switched to the lasers (mercury) and the pinhole-value needed to be adjusted. Three pictures were taken: one in the green channel, one in the red channel and one of in pseudo-transmission light. GFP molecules gave a green signal, while the chlorophyll visualized the chloroplasts as red dots. In order to compare the pictures, a scale bar was added in the pictures.