Team:Paris Bettencourt/Safety

From 2014.igem.org

(Difference between revisions)
 
(17 intermediate revisions not shown)
Line 114: Line 114:
</table>
</table>
<div id=part1 class=project>
<div id=part1 class=project>
-
<p class=text2></p>
+
<p class=text2>It included rules about protocols in the lab, protective clothing and equipment, decontamination methods and practices, prevention of the transfer of genetic material and microorganisms, handling of chemicals, use of machines and emergency procedures. </p>
<h6>Safety Training and Lab Rules</h6><br>
<h6>Safety Training and Lab Rules</h6><br>
-
<p class=text1>Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut imperdiet diam eget quam imperdiet imperdiet. Mauris dapibus risus felis, sed ornare diam accumsan aliquet. Sed eu turpis porta, porttitor tortor et, condimentum augue. Curabitur a maximus nisi. Vivamus vitae magna ex. Donec congue auctor odio vitae tempus. In a gravida neque, et tristique tortor. Phasellus a odio sit amet enim ornare lobortis. Morbi sodales, diam non rutrum aliquam, ligula mauris consectetur urna, sed interdum quam risus sit amet enim. Aenean euismod enim magna, id pretium eros molestie non. Proin rutrum lobortis leo, sit amet congue erat. Nulla congue pellentesque augue porta dignissim. Pellentesque quis ex sollicitudin, condimentum risus varius, aliquet ipsum. Ut pulvinar aliquet maximus. Praesent imperdiet interdum commodo. </p>
+
<p class=text1>At the beggining of the competition, all team members recieved a Safety Training for working in the Biosafety Level 1 laboratory. This training as conducted by the Biosafety officer for INSERM U1001 and it included best laboratory practices as described in the WHO laboratory biosafety manual. </p>
</div>
</div>
-
<div id=part2 class=project>
+
<div id=part2 class=project><br><br><br>
-
<p class=text2></p>
+
<p class=text2>Nobody working with these samples is immunodepressed or susceptible to develop a severe infection.</br></br> None of the organisms that we have genetically modified represent a higher risk than the wild types, that are already known to be harmless. The modifications that we introduce make bacteria produce volatile compounds -that are useless for themselves- or to degrade molecules present in the human body. These modified strains do not gain a fitness advantage and would probably be outcompeted in any ecological niche by the natural bacteria. We understand that these engineered strains would not be able to efficiently spread in the environment of they were released. Also, we do not think this project could have a malicious mis-use.</p>
-
<h6>The risque of the project</h6><br>
+
<h6>Biosafety issues</h6><br>
-
<p class=text1>Lorem ipsum dolor sit amet, consectetur adipiscing elit. Nullam bibendum purus eu neque finibus, eget pellentesque sapien viverra. Vestibulum ultrices posuere tempor. Maecenas ultrices sodales magna ac placerat. Sed a ex dignissim, ornare metus non, malesuada arcu. Etiam ullamcorper odio leo, at molestie eros sollicitudin in. Morbi aliquam scelerisque facilisis. Aenean tincidunt aliquam erat, quis ullamcorper nulla accumsan ac. Proin interdum nibh quam, in lacinia ipsum dignissim at. Nunc elementum lacus sed purus pharetra tincidunt. Sed ac velit vel turpis pulvinar accumsan ut in mauris. Praesent ac dapibus dui. Nullam finibus turpis et turpis sagittis congue. </p>
+
<p class=text1>The strains we are working with are <i>E. coli</i>, <i>Corynebacterium spp.</i> and <i>Bacillus subtilis</i>. All of them are classified in Biosafety level 1.</br></br> One of our projects includes the sampling of human microbiome. After doing research, we found no legal issues or specific authorisation in order to do so. There is a consent form we ask people to fill before taking their samples that includes information about how we will use the data and the protection of private information.</br></br> Human skin microbiome might contain <i>Staphilococcus aureus</i> in 20% of the cases. This organism can cause blood infection if introduced in the human body. Therefore, we extremely careful with these samples and always wear protection such as gloves, coats and glasses and decontaminate the bench we are working with. </p>
</div>
</div>
-
<div id=part3 class=project>
+
<div id=part3 class=project><br><br><br>
-
<p class=text2></p>
+
<p class=text2>- <i>Corynebacterium striatum</i>: Biosafety level 1. It is the main responsible for body odor and was used in the 'Don't sweat it' project. </br>
-
<h6>The organisms we used</h6><br>
+
- <i>Corynebacterium glutamicum</i>: Biosafety level 1. It was used as control as transformation techniques have been described for this strain, but not for <i>C. striatum</i>.</p>
-
<p class=text1><a href="https://2014.igem.org/File:Paris_Bettencourt_Safety2014_Spreadsheet.xls">Here is the spreadsheet</a> about all the biobricks and the bacteria we used for the project.</br>For our experiment we used 4 different kind of bacteria :
+
<h6>Bacterial strains used</h6><br>
-
- <i>Escherishia Coli</i>, Biosafety level 1</br>
+
<p class=text1><a target="blank" href="https://2014.igem.org/File:Paris_Bettencourt_Safety2014_Spreadsheet.xls">In this spreadsheet</a> there is a detailed description about all the BioBricks and bacteria used in this project.</br></br>Four strains were used:</br>
-
- <i>Corynebacterium Striatum</i>, Biosafety level 1</br>
+
- <i>Escherichia coli</i>: Biosafety level 1. As a biological chassis to clone genes responsible for different odors. </br>
-
- <i>Bacillus subtilis</i>, Biosafety level 1</br>
+
- <i>Bacillus subtilis</i>: Biosafety level 1. Used in 'Goody Two Shoes' as they are the main bacteria responsible for food odor. Wild type strains as well as three different knock out strains were used.</br><br><br>
-
- <i>Corynebacterium Glutamicum</i>, Biosafety level 1</p>
+
 
 +
</p>
</div>
</div>
</body>
</body>
</html>
</html>
{{:Team:Paris_Bettencourt/Footer}}
{{:Team:Paris_Bettencourt/Footer}}

Latest revision as of 22:50, 17 October 2014

It included rules about protocols in the lab, protective clothing and equipment, decontamination methods and practices, prevention of the transfer of genetic material and microorganisms, handling of chemicals, use of machines and emergency procedures.

Safety Training and Lab Rules

At the beggining of the competition, all team members recieved a Safety Training for working in the Biosafety Level 1 laboratory. This training as conducted by the Biosafety officer for INSERM U1001 and it included best laboratory practices as described in the WHO laboratory biosafety manual.




Nobody working with these samples is immunodepressed or susceptible to develop a severe infection.

None of the organisms that we have genetically modified represent a higher risk than the wild types, that are already known to be harmless. The modifications that we introduce make bacteria produce volatile compounds -that are useless for themselves- or to degrade molecules present in the human body. These modified strains do not gain a fitness advantage and would probably be outcompeted in any ecological niche by the natural bacteria. We understand that these engineered strains would not be able to efficiently spread in the environment of they were released. Also, we do not think this project could have a malicious mis-use.

Biosafety issues

The strains we are working with are E. coli, Corynebacterium spp. and Bacillus subtilis. All of them are classified in Biosafety level 1.

One of our projects includes the sampling of human microbiome. After doing research, we found no legal issues or specific authorisation in order to do so. There is a consent form we ask people to fill before taking their samples that includes information about how we will use the data and the protection of private information.

Human skin microbiome might contain Staphilococcus aureus in 20% of the cases. This organism can cause blood infection if introduced in the human body. Therefore, we extremely careful with these samples and always wear protection such as gloves, coats and glasses and decontaminate the bench we are working with.




- Corynebacterium striatum: Biosafety level 1. It is the main responsible for body odor and was used in the 'Don't sweat it' project.
- Corynebacterium glutamicum: Biosafety level 1. It was used as control as transformation techniques have been described for this strain, but not for C. striatum.

Bacterial strains used

In this spreadsheet there is a detailed description about all the BioBricks and bacteria used in this project.

Four strains were used:
- Escherichia coli: Biosafety level 1. As a biological chassis to clone genes responsible for different odors.
- Bacillus subtilis: Biosafety level 1. Used in 'Goody Two Shoes' as they are the main bacteria responsible for food odor. Wild type strains as well as three different knock out strains were used.


Centre for Research and Interdisciplinarity (CRI)
Faculty of Medicine Cochin Port-Royal, South wing, 2nd floor
Paris Descartes University
24, rue du Faubourg Saint Jacques
75014 Paris, France
+33 1 44 41 25 22/25
paris-bettencourt-igem@googlegroups.com
Copyright (c) 2014 igem.org. All rights reserved.