Several programs were used by members on the team to design and ultimately fabricate microfluidic devices. Initially, traditional computer aided design software packages were used such as AutoCAD and Solidworks. These packages provide advanced features which designers can wield to make complex devices with varying functions such as mixing and trapping cells. Alternative software packages were explored such as the open source vector graphics software Inkscape which proved to be easy to use in the design of a microfluidic device. Inkscape is an open source analogue to Adobe Illustrator, a common vector graphics editing software. Inkscape is easy to use and with a few online tutorials, ideas for microfluidic designs can be turned into realities.<br> | Several programs were used by members on the team to design and ultimately fabricate microfluidic devices. Initially, traditional computer aided design software packages were used such as AutoCAD and Solidworks. These packages provide advanced features which designers can wield to make complex devices with varying functions such as mixing and trapping cells. Alternative software packages were explored such as the open source vector graphics software Inkscape which proved to be easy to use in the design of a microfluidic device. Inkscape is an open source analogue to Adobe Illustrator, a common vector graphics editing software. Inkscape is easy to use and with a few online tutorials, ideas for microfluidic designs can be turned into realities.<br> | ||
<h3><b><span style="color:#ffffff"> Microfluidic Prototyping using a Vinyl Cutter<br></h3></b> | <h3><b><span style="color:#ffffff"> Microfluidic Prototyping using a Vinyl Cutter<br></h3></b> | ||
- | In order to rapidly prototype microfluidic devices of different geometries and designs, our team explored fabrication techniques that bypassed the complicated photolithography process that is standard for microfluidic devices in research laboratories. Photolithography has the benefit of achieving very fine resolution and fine details for pinpoint fluid manipulation, but it is detracted from its lengthy creation process. The time scale from device design to fabrication of a working device using photolithography is on the order of 2-3 days and uses a variety of expensive and highly technical equipment that is not readily accessible to many iGEM teams. <br> | + | In order to rapidly prototype microfluidic devices of different geometries and designs, our team explored fabrication techniques that bypassed the complicated photolithography process that is standard for microfluidic devices in research laboratories. Photolithography has the benefit of achieving very fine resolution and fine details for pinpoint fluid manipulation, but it is detracted from its lengthy creation process. The time scale from device design to fabrication of a working device using photolithography is on the order of 2-3 days and uses a variety of expensive and highly technical equipment that is not readily accessible to many iGEM teams. <br><img src="https://static.igem.org/mediawiki/parts/8/8b/VU_MF_Photo_1_%281%29.JPG" align="right" width="250"><img src="https://static.igem.org/mediawiki/parts/c/cc/VU_MF_Photo_1.JPG" align="right" width="250"> |
<br> | <br> | ||
Our team focused on bypassing the entire photolithography process by using a commercially available arts and crafts vinyl cutter (Silhouette) to produce device masters. Arts and crafts vinyl cutters are typically used to craft complex shapes and figures for use in decorations. A vinyl cutter has a resolution on the order of 250 microns which means that the devices made using this technique are considerably larger than those made using standard photolithography techniques. While the devices obtained from vinyl cutting are larger, for many synthetic biology applications this is not an issue. For the purpose of E. chrono, the size of the channels simply affected the total amount of fluid needing to be pumped into the device. | Our team focused on bypassing the entire photolithography process by using a commercially available arts and crafts vinyl cutter (Silhouette) to produce device masters. Arts and crafts vinyl cutters are typically used to craft complex shapes and figures for use in decorations. A vinyl cutter has a resolution on the order of 250 microns which means that the devices made using this technique are considerably larger than those made using standard photolithography techniques. While the devices obtained from vinyl cutting are larger, for many synthetic biology applications this is not an issue. For the purpose of E. chrono, the size of the channels simply affected the total amount of fluid needing to be pumped into the device. | ||
+ | <br> | ||
As mentioned previously, the main benefit of using a vinyl cutter is the rapid production of microfluidic masters. A vinyl cutter is able to take a device design to a master and ultimately a device in roughly an hour. By simplifying and speeding up the design and fabrication process, vinyl cutting can allow iGEM teams with no microfluidic knowledge to rapidly develop their own devices for testing. Using an open source design software such as Inkscape allows a team to rapidly formulate and then test a microfluidic device within an afternoon. <br> | As mentioned previously, the main benefit of using a vinyl cutter is the rapid production of microfluidic masters. A vinyl cutter is able to take a device design to a master and ultimately a device in roughly an hour. By simplifying and speeding up the design and fabrication process, vinyl cutting can allow iGEM teams with no microfluidic knowledge to rapidly develop their own devices for testing. Using an open source design software such as Inkscape allows a team to rapidly formulate and then test a microfluidic device within an afternoon. <br> | ||
- | The process for using a Silhouette vinyl cutter to fabricate a microfluidic device is outlined below.<br> | + | The process for using a Silhouette vinyl cutter to fabricate a microfluidic device is outlined below.<br> <img src="https://static.igem.org/mediawiki/parts/f/f0/VU_MF_Photo_2_%281%29.JPG" align="right" width="250"> <img src="https://static.igem.org/mediawiki/parts/b/bf/VU_MF_Photo_2.JPG" align="right" width="250"> |
<h3><b><span style="color:#ffffff"> Converting a Design to a Vinyl Master<br></b></h3> | <h3><b><span style="color:#ffffff"> Converting a Design to a Vinyl Master<br></b></h3> | ||
1) Import the design for microfluidic device into Silhouette Studio, the vinyl cutting software used to make designs. Note: for Design process, see Microfluidic Device Design instructions<br> | 1) Import the design for microfluidic device into Silhouette Studio, the vinyl cutting software used to make designs. Note: for Design process, see Microfluidic Device Design instructions<br> | ||
2) With device inside Silhouette, check to make sure dimensions are within the vinyl cutter resolution limits. No feature of the device should be smaller than 250 microns, this rule applies predominantly to channel widths.<br> | 2) With device inside Silhouette, check to make sure dimensions are within the vinyl cutter resolution limits. No feature of the device should be smaller than 250 microns, this rule applies predominantly to channel widths.<br> | ||
- | 3) Place vinyl paper inside printer and load the paper in place<br> | + | 3) Place vinyl paper inside printer and load the paper in place<br> |
- | 4) Place the blade setting to 2<br> | + | 4) Place the blade setting to 2<br> |
5) On the right hand side there is are several options for vinyl cutting, click Include Edges and then submit the job to be printed.<br> | 5) On the right hand side there is are several options for vinyl cutting, click Include Edges and then submit the job to be printed.<br> | ||
6) Once the device is cut onto a vinyl sheet, using a razor blade peel away the surrounding vinyl so that only the cut out is left<br> | 6) Once the device is cut onto a vinyl sheet, using a razor blade peel away the surrounding vinyl so that only the cut out is left<br> | ||
7) With tweezers and razor blade, pick up the cutout and place on a glass slide<br> | 7) With tweezers and razor blade, pick up the cutout and place on a glass slide<br> | ||
- | 8) Flatten the cutout onto the glass slide, this creates the “master” with which microfluidic devices can be manufactured | + | 8) Flatten the cutout onto the glass slide, this creates the “master” with which microfluidic devices can be manufactured <img src="https://static.igem.org/mediawiki/parts/2/2a/VU_MF_Photo_3_%281%29.JPG" align="right" width="250"> |
<h3><b><span style="color:#ffffff"> Fabricating a PDMS device using a Vinyl Master<br></b></h3> | <h3><b><span style="color:#ffffff"> Fabricating a PDMS device using a Vinyl Master<br></b></h3> | ||
9) Prepare a PDMS solution with 10:1 ratio of PDMS to epoxy and mix well<br> | 9) Prepare a PDMS solution with 10:1 ratio of PDMS to epoxy and mix well<br> | ||
Line 107: | Line 108: | ||
12) Once the bubbles have been removed from the PDMS, place the Petri dish in a warm incubator to cure for 8 hours or overnight. <br> | 12) Once the bubbles have been removed from the PDMS, place the Petri dish in a warm incubator to cure for 8 hours or overnight. <br> | ||
13) In order to remove the device, a razor blade or scalpel can be used to cut out the device from the surrounding PDMS inside the petri dish.<br> | 13) In order to remove the device, a razor blade or scalpel can be used to cut out the device from the surrounding PDMS inside the petri dish.<br> | ||
- | 14) The vinyl master can be removed from the bottom of the device and either thrown away or reused for fabrication of more devices<br> | + | 14) The vinyl master can be removed from the bottom of the device and either thrown away or reused for fabrication of more devices<br> |
15) Take a 1/16” OD syringe tip and use it to “punch” a hole inside the microfluidic inlet channel and inside the microfluidic outlet channel<br> | 15) Take a 1/16” OD syringe tip and use it to “punch” a hole inside the microfluidic inlet channel and inside the microfluidic outlet channel<br> | ||
- | 16) Once the device holes have been punched, the device can be plasma bonded to a glass slide or coverslip by treating the bottom of the microfluidic device (where the channels are open) with a plasma wand or plasma oven for 45 seconds and then bonding to a plasma treated glass slide.<br> | + | 16) Once the device holes have been punched, the device can be plasma bonded to a glass slide or coverslip by treating the bottom of the microfluidic device (where the channels are open) with a plasma wand or plasma oven for 45 seconds and then bonding to a plasma treated glass slide.<br> <img src="https://static.igem.org/mediawiki/parts/9/94/VU_MF_Photo_3.JPG" align="right" width="250"> <img src="https://static.igem.org/mediawiki/parts/e/e9/VU_MF_Photo_4.JPG" align="right" width="250"> |
<br> | <br> | ||
<span style="color:#ffffff"> | <span style="color:#ffffff"> |