Team:TU Delft-Leiden/Modeling/Curli/Colony
From 2014.igem.org
(22 intermediate revisions not shown) | |||
Line 13: | Line 13: | ||
<p> | <p> | ||
Now that we determined values for \(\rho_{curli}\) and \(r_{cond}\) at the cell level, we can finally predict if our system works as expected and capture the dynamics of our system. The product we aim for is a chip where two parallel electrodes are a distance <i>w</i> apart. Between the electrodes, cells will grow and start building curli in the presence of an inducer. Then, we will measure the conductance of the resulting biofilm, which is related to the amount of inducer. Since even with bound gold nanoparticles the conductivity of the curli is very low, the chip is designed such that the electrodes are as long as possible. <br> | Now that we determined values for \(\rho_{curli}\) and \(r_{cond}\) at the cell level, we can finally predict if our system works as expected and capture the dynamics of our system. The product we aim for is a chip where two parallel electrodes are a distance <i>w</i> apart. Between the electrodes, cells will grow and start building curli in the presence of an inducer. Then, we will measure the conductance of the resulting biofilm, which is related to the amount of inducer. Since even with bound gold nanoparticles the conductivity of the curli is very low, the chip is designed such that the electrodes are as long as possible. <br> | ||
- | + | For the modeling, we can make some approximations. Since the cells are grown on a chip, we assume that the cells and curli grow on a surface. This reduces our problem from 3D to 2D. This saves much computational time and memory. For this model, we take a chip of 500 by 500 µm. The electrodes are placed parallel to the y axis on x = 20 µm and x = 480 µm. The next approximation is that the cells are already present when they are induced by DNT/TNT, we neglect cell growth. In our model, <i>E. coli</i> are present with a density of \(\rho_{cell}\). Furthermore, we assume there is no spatial correlation between the cells; hence we place them at random on our chip. The cell density we use is \( \ 2 \cdot 10^4 \) cells per \( mm^2 \). We would like to model higher cell densities and larger chips. However, the memory cost of the solution increases with the amount of cells squared and, even when the code is neatly vectorized, the computational time increases drastically.<br> | |
- | + | Firstly, we want to prove that our system works as expected. So, we want to predict if a conductive path between the two electrodes arise at a certain point in time and at which time this happens. Secondly, we not only want to answer the question if our system works as expected with a yes or no answer, but we also want to make quantitative predictions about the resistance between the two electrodes of our system in time. We do this by modeling the curli growth on the colony level; each cell is now visualized and has curli growth. Now, we have come up with two different approaches to answer these questions: | |
- | + | ||
- | <br> | + | |
- | + | ||
- | + | ||
- | We have come up with two different approaches: | + | |
<ul> | <ul> | ||
<li> | <li> | ||
Line 31: | Line 26: | ||
<figure> | <figure> | ||
- | <img src="https://static.igem.org/mediawiki/2014/e/e1/TUDelft_2014_cellradius.png" width=" | + | <img src="https://static.igem.org/mediawiki/2014/e/e1/TUDelft_2014_cellradius.png" width="60%" height="60%"> |
<figcaption> | <figcaption> | ||
Figure 1: The green lines are the conductive radius plotted versus the time for 100 cells with a critical density of \( \rho_{crit}=1204 \) curli subuntis \( \mu m ^{-3} \). The orange red represents the mean conductive radius and the dark blue lines represent two standard deviations from the mean. | Figure 1: The green lines are the conductive radius plotted versus the time for 100 cells with a critical density of \( \rho_{crit}=1204 \) curli subuntis \( \mu m ^{-3} \). The orange red represents the mean conductive radius and the dark blue lines represent two standard deviations from the mean. | ||
Line 119: | Line 114: | ||
</li> | </li> | ||
</ul> | </ul> | ||
+ | <li> | ||
+ | <a href="https://2014.igem.org/Team:TU_Delft-Leiden/Modeling/Curli/Reflection"> | ||
+ | <p>Critical Reflection on our Model</p> | ||
+ | </a> | ||
+ | </li> | ||
</li> | </li> | ||
</ul> | </ul> | ||
Line 133: | Line 133: | ||
<p> | <p> | ||
- | We have designed our chip as a 500 by 500 µm square with an electrode on the left and right side. On this chip, we place cells randomly with a density of \(\rho_{cell}\). Subsequently, we increase the conductive radius of each cell in time, corresponding with our findings on the cellular level, see figure 1. A connection is created from one electrode to the other electrode when there is a conductive path between them. Conductive paths consists of cells that have a connection with each other. Cells have a connection with each other when there is an overlap between their conductive radii. | + | We have designed our chip as a 500 by 500 µm square with an electrode on the left and right side. On this chip, we place cells randomly with a density of \(\rho_{cell}\). Subsequently, we increase the conductive radius of each cell in time, corresponding with our findings on the cellular level, see figure 1. A connection is created from one electrode to the other electrode when there is a conductive path between them. Conductive paths consists of cells that have a connection with each other. Cells have a connection with each other when there is an overlap between their conductive radii. We have programmed this by calculating the distances of all cells with all other cells and then calculate if that distance is greater than the respective conductive radius of each cell added to each other. A simulation of our resulting model is shown in figure 2. Percolation is computed by applying an algorithm that can find clusters of connected cells. When one of the clusters connects both electrodes, there is percolation. |
</p> | </p> | ||
- | |||
- | |||
<figure> | <figure> | ||
- | <img class="theimage" src="https://static.igem.org/mediawiki/2014/1/1d/TU_Delft_2014_model_curli_colony_static.png" alt="meh" width=" | + | <img class="theimage" src="https://static.igem.org/mediawiki/2014/1/1d/TU_Delft_2014_model_curli_colony_static.png" alt="meh" width="60%" height="60%"/> |
- | <img class="theimage2 hidden" src="https://static.igem.org/mediawiki/2014/9/9f/TU_Delft_2014_model_curli_colony.gif" alt="meh" width=" | + | <img class="theimage2 hidden" src="https://static.igem.org/mediawiki/2014/9/9f/TU_Delft_2014_model_curli_colony.gif" alt="meh" width="60%" height="60%"/> |
<figcaption> | <figcaption> | ||
- | Figure 2: NorthWest: A visual representation of our cells on the plate. The circles represent the cells with an increasing conductive radius. In this simulation there are 5000 cells present on a chip of 500µmx500µm. NorthEast: A spy matrix of 5000x5000 where the blue dots represent connections between the individual cells. A blue dot on position x,y means that cell x is connected with y. Each cell is connected to itself (diagonal). At the point of percolation, \( \approx 0.1 \% \) of the matrix is connected, meaning that each cell is on average connected to 5 others. SouthWest: Each square of nxn represents a cluster of n connected cells. The squares are sorted from small to large. SouthEast: This figure shows the largest cluster of cells in different | + | Figure 2: NorthWest: A visual representation of our cells on the plate. The circles represent the cells with an increasing conductive radius. In this simulation there are 5000 cells present on a chip of 500µmx500µm. NorthEast: A spy matrix of 5000x5000 where the blue dots represent connections between the individual cells. A blue dot on position x,y means that cell x is connected with y. Each cell is connected to itself (diagonal). At the point of percolation, \( \approx 0.1 \% \) of the matrix is connected, meaning that each cell is on average connected to 5 others. SouthWest: Each square of nxn represents a cluster of n connected cells. The squares are sorted from small to large. SouthEast: This figure shows the largest cluster of cells in different colors. <b> Click to play!</b> |
</figcaption> | </figcaption> | ||
</figure> | </figure> | ||
Line 161: | Line 159: | ||
<p> | <p> | ||
- | We have stochasticity in our model, as we place the cells randomly with a density of \(\rho_{cell}\) on the chip. Therefore, we simulated our model 100 times and for each point in time we checked if there was percolation. We will only get a yes (1) or no (0) response. This enables us to find the chance of percolation at each time point, shown in figure 3 as the yellow line. The yellow line shows a sharp transition between 1.5 and 2 hours. Since this is a Bernoulli process | + | We have stochasticity in our model, as we place the cells randomly with a density of \(\rho_{cell}\) on the chip. Therefore, we simulated our model 100 times and for each point in time we checked if there was percolation. We will only get a yes (1) or no (0) response. This enables us to find the chance of percolation at each time point, shown in figure 3 as the yellow line. The yellow line shows a sharp transition between 1.5 and 2 hours. Since this is a Bernoulli process [1], the variance is exactly equal to p(1-p). The variance must be as low as possible to get reliable measurement results. This is achieved when the transition from no percolation to percolation is as sharp as possible. <br> |
- | At first we assumed | + | At first we assumed that \(r_{cond}\) is the same for each cell at each point in time (figure 1 red line). However, figure 1 shows that there clearly is some cellular variation in \(r_{cond}\). Therefore, we added a new feature to our model; the conductive radius of each cell can now deviate from the mean \(r_{cond}\) with the standard deviation as found in figure 1. We simulated our new model again 100 times and for each point in time we checked the chance of percolation, see figure 3 as the blue line. Fortunately, the resulting curve is very similar to the curve without variation in \(r_{cond}\) (yellow line). This means that cellular variation has little influence on the chance of percolation at each point in time. Therefore, the results of our model are robust to cellular variation and it is likely that many factors that could increase the cellular variation, e.g. different CsgA or CsgB protein production rates, are relatively unimportant. |
</p> | </p> | ||
Line 190: | Line 188: | ||
<br> | <br> | ||
- | <h5> Influence of the promoter strength on the moment of percolation | + | <h5> Influence of the promoter strength on the moment of percolation</h5> |
<p> | <p> | ||
- | + | As we want our system to be usable as a biosensor, it has to be strongly dependent on the analyte concentration, and therefore the CsgB production rate. To verify this is the case, we have run the same gene and cell level simulations as before, with the same parameters, including the critical density. The only exception is that the CsgB production rate is reduced by 50%. (\(p_B = 6.5 \cdot 10^{-14} M/s\) instead of (\(p_B = 1.3 \cdot 10^{-13} M/s \) ). The result is shown in figure 5. | |
</p> | </p> | ||
<br> | <br> | ||
Line 199: | Line 197: | ||
<img src="https://static.igem.org/mediawiki/2014/0/02/TUDelft2014_Percolation_InductionDifferences.png" width="60%" height="60%"> | <img src="https://static.igem.org/mediawiki/2014/0/02/TUDelft2014_Percolation_InductionDifferences.png" width="60%" height="60%"> | ||
<figcaption> | <figcaption> | ||
- | Figure 5: The | + | Figure 5: The change of induction for t=0:10 hours, when cellular differences are included in the cell level for different induction strengths. The orange line is created by reducing the promoter strength of the cyan line (\(p_B = 1.3 \cdot 10^{-13} M/s \) ) by 50%. |
</figcaption> | </figcaption> | ||
</figure> | </figure> | ||
Line 206: | Line 204: | ||
<p> | <p> | ||
- | + | From the figure, we see that there is a very distinguishable difference between the two lines. First of all, the moment of percolation is much later (4.5 hours as opposed to 1.5 hours). Equally important is that the transition from no percolation to percolation is much less sharper. | |
- | + | ||
- | + | ||
</p> | </p> | ||
Line 216: | Line 212: | ||
<h3> Resistance </h3> | <h3> Resistance </h3> | ||
<p> | <p> | ||
- | To calculate the conductance (which is the inverse of the resistance) as function of time we repeat the following steps: | + | To calculate the conductance (which is the inverse of the resistance) as function of time, we repeat the following steps: |
<ul> | <ul> | ||
- | <li>Place | + | <li>Place the cells on the chip. </li> |
<li> Compute the conductance between the cells. </li> | <li> Compute the conductance between the cells. </li> | ||
<li> Compute the conductance between the electrodes. </li> | <li> Compute the conductance between the electrodes. </li> | ||
Line 237: | Line 233: | ||
<p> | <p> | ||
- | The factor \( 1/r \) is introduced to account for the conductance of the wires itself, which is inversely proportional to the length of the conducting wire | + | The factor \( 1/r \) is introduced to account for the conductance of the wires itself, which is inversely proportional to the length of the conducting wire [2]. Further away from the cell, the wires need a longer distance to go to the cell. Since we want to know the strength of the connection between the cells, we have to include this factor. For a straight line this is inversely proportional to the distance. For a single curli fibril, this relation does not hold. However, we assume that the curli density is high, thus there are many connections between the curli. Then there is a pathway from the origin to \( r \) roughly proportional to the distance from the cell. To find the total conductance, we integrate on both sides. To account for the fact that both volume elements \(dV\) are the same, we make use of the Dirac-delta function \(\delta_3\) [3]. This gives us the following: |
</p> | </p> | ||
Line 280: | Line 276: | ||
<p> | <p> | ||
- | We will now use the | + | We will now use that the curli density can be described as (see section <a href="https://2014.igem.org/Team:TU_Delft-Leiden/Modeling/Curli/Cell">Cell Level Model</a>): |
</p> | </p> | ||
Line 287: | Line 283: | ||
<p> | <p> | ||
- | For simplicity we demonstrate what the formula would look like when only | + | For simplicity we demonstrate what the formula would look like when only one exponential term is present. Later we will show how you can use this to get an expression for the entire formula. |
</p> | </p> | ||
Line 365: | Line 361: | ||
<p> | <p> | ||
- | The same derivation has also been done by us for the case that \( \rho_1(r) = \ C_{1}e^{-\frac{r}{C_{2}}} \) and \( \rho_2(r) = \ C_{3}e^{-\frac{r}{C_{4}}} \). The conductance between the two electrodes is then | + | The same derivation has also been done by us for the case that \( \rho_1(r) = \ C_{1}e^{-\frac{r}{C_{2}}} \) and \( \rho_2(r) = \ C_{3}e^{-\frac{r}{C_{4}}} \). The conductance between the two electrodes is then: |
</p> | </p> | ||
$$ \sigma (y) = \ \frac{4 \pi C_{1}C_3 C_2^2 C_4^2}{y \left( C_2^2 - C_4^2 \right)} \left( e^{-\frac{y}{C_2}} -e^{-\frac{y}{C_4}} \right) \tag{16} $$ | $$ \sigma (y) = \ \frac{4 \pi C_{1}C_3 C_2^2 C_4^2}{y \left( C_2^2 - C_4^2 \right)} \left( e^{-\frac{y}{C_2}} -e^{-\frac{y}{C_4}} \right) \tag{16} $$ | ||
- | <p> | + | <p> In our case \( \rho_{1}= \rho_{2} = \rho_a + \rho_b \), with \( \rho_a = C_1 e^{-\frac{r}{C_2}} \) and \( \rho_b = C_3 e^{-\frac{r}{C_4}} \). We can use the linearity of the system and using equation 1:</p> |
$$ d \sigma (y) = \ \frac{\rho_{1}}{r_1} dV \frac{\rho_2}{r_2} dV = \ \frac{\rho_{a}}{r_1} dV \frac{\rho_a}{r_2} dV + \ \frac{\rho_{b}}{r_1} dV \frac{\rho_b}{r_2} dV + 2* \frac{\rho_{a}}{r_1} dV \frac{\rho_b}{r_2} dV\tag{17} $$ | $$ d \sigma (y) = \ \frac{\rho_{1}}{r_1} dV \frac{\rho_2}{r_2} dV = \ \frac{\rho_{a}}{r_1} dV \frac{\rho_a}{r_2} dV + \ \frac{\rho_{b}}{r_1} dV \frac{\rho_b}{r_2} dV + 2* \frac{\rho_{a}}{r_1} dV \frac{\rho_b}{r_2} dV\tag{17} $$ | ||
<p> | <p> | ||
- | These will form three integrals in the same form as | + | These will form three integrals in the same form as we have previously derived! The final result then becomes:</p> |
$$ \sigma (y) = \ 2 \pi \left( C_{1}^2 C_2 e^{-\frac{y}{C_2}} + C_{3}^2 C_4 e^{-\frac{y}{C_4}} + \frac{4 C_{1}C_3 C_2^2 C_4^2}{y \left( C_2^2 - C_4^2 \right)} \left( e^{-\frac{y}{C_2}} -e^{-\frac{y}{C_4}} \right) \right) \tag{18}$$ | $$ \sigma (y) = \ 2 \pi \left( C_{1}^2 C_2 e^{-\frac{y}{C_2}} + C_{3}^2 C_4 e^{-\frac{y}{C_4}} + \frac{4 C_{1}C_3 C_2^2 C_4^2}{y \left( C_2^2 - C_4^2 \right)} \left( e^{-\frac{y}{C_2}} -e^{-\frac{y}{C_4}} \right) \right) \tag{18}$$ | ||
Line 391: | Line 387: | ||
<br> | <br> | ||
- | <h5>Influence of the chip size | + | <h5>Influence of the chip size</h5> |
<p> | <p> | ||
- | We have calculated the conductance as function of time for | + | We have calculated the conductance as function of time for different dimensions of our plate. We varied the distance between the electrodes between 210, 460 and 960 \( \mu m \). The length of the electrodes is kept at \( 500 \mu m\). The result is shown in figure 6. |
</p> | </p> | ||
<figure> | <figure> | ||
- | <img src="https://static.igem.org/mediawiki/2014/c/c5/TUDelft2014_Colony_DifferentSizes.png" width=" | + | <img src="https://static.igem.org/mediawiki/2014/c/c5/TUDelft2014_Colony_DifferentSizes.png" width="60%" height="60%"> |
<figcaption> | <figcaption> | ||
- | Figure 6: The conductance of our system as function of time, using the results from the gene and the colony level. Different simulations have been done with different chip sizes. The length of the chips is in all cases \( 500 \mu m \). The distance between is varied from \( 210 \mu m \) (green lines) to \( 460 \mu m \) (red lines) and \( 960 \mu m \) (blue | + | Figure 6: The conductance of our system as function of time, using the results from the gene and the colony level. Different simulations have been done with different chip sizes. The length of the chips is in all cases \( 500 \mu m \). The distance between the electrodes is varied from \( 210 \mu m \) (green lines) to \( 460 \mu m \) (red lines) and \( 960 \mu m \) (blue lines). There are multiple lines for the green and red lines as we repeated the simulations multiple times. However the simulation for when the electrodes were \( 960 \mu m \) apart was only performed once. |
</figcaption> | </figcaption> | ||
</figure> | </figure> | ||
Line 409: | Line 405: | ||
<p> | <p> | ||
- | From figure 6 we | + | From figure 6 we draw a couple of conclusions: |
<ul> | <ul> | ||
<li> | <li> | ||
- | First of all, a very strong trend | + | First of all, there is a very strong trend in the red lines. From 0-2 hours, the conductance is increasing rapidly. We have already seen from the gene level modeling that this is the result of rapid curli growth due to the abundance of CsgA at t=0 hours. When all initial CsgA proteins have formed curli, the increase in curli is linear with time and so is the conductance. This is unexpected, since from the resistor example in percolation theory, an exponential increase was expected, see the <a href="https://2014.igem.org/Team:TU_Delft-Leiden/Modeling/Techniques#PercolationTheory">percolation theory</a> section. From these results we conclude that it is not necessary to wait a very long time to see any change in conductivity in our system. The conductivity at 10 hours is barely twice as large as the conductivity at 2 hours. |
</li> | </li> | ||
<li> | <li> | ||
- | When the electrodes are positioned further away, the conductance decreases inversely proportional. An increase from \( 210 \mu m \) to \( 460 \mu m \) (factor 2.2) results in a decrease in conductivity from \( 6.1e-13 \) a.u. to \(2.6e-13\) a.u. (factor \(2.3^{-1}\). However, | + | When the electrodes are positioned further away, the conductance decreases inversely proportional. An increase from \( 210 \mu m \) to \( 460 \mu m \) (factor 2.2) results in a decrease in conductivity from \( 6.1e-13 \) a.u. to \(2.6e-13\) a.u. (factor \(2.3^{-1}\). However, the lines maintain their same shapes. |
</li> | </li> | ||
<li> | <li> | ||
- | The relative uncertainty of the green and red curves is not significantly different. The mean relative uncertainty of the larger | + | The relative uncertainty of the green and red curves is not significantly different. The mean relative uncertainty of the larger chip (red lines) is 3.7 % as opposed to 3.4% for the smaller chip (green lines). The relative uncertainty is smallest at 1:15 hr, where the slope is steepest for both curves (2.6%) and the relative uncertainty increases with time. We haven't obtained a relative uncertainty for when the electrodes were \( 960 \mu m \) apart, as we performed that simulation only once. |
</li> | </li> | ||
</ul> | </ul> | ||
Line 426: | Line 422: | ||
<h5>Influence of the cell density</h5> | <h5>Influence of the cell density</h5> | ||
<p> | <p> | ||
- | Another parameter we investigated is the influence of cell density on the conductivity of the system. From percolation theory we have learned that this | + | Another parameter we investigated is the influence of cell density on the conductivity of the system. From percolation theory we have learned that this has a strong influence on the moment of percolation. |
</p> | </p> | ||
<figure> | <figure> | ||
- | <img src="https://static.igem.org/mediawiki/2014/f/ff/TUDelft2014_Colony_CellDens.png" width=" | + | <img src="https://static.igem.org/mediawiki/2014/f/ff/TUDelft2014_Colony_CellDens.png" width="60%" height="60%"> |
<figcaption> | <figcaption> | ||
- | Figure 7: The conductance of our chip ( \( 500\mu m | + | Figure 7: The conductance of our chip ( \( 500\mu m \ by \ 500\mu m \) as function of time. Two different cell densities have been simulated. The red lines show simulations with a cell density of \( 2 \cdot 10^4 cells / mm^2\). The blue lines show the results with a cell density of \( 2.4 \cdot 10^4 cells / mm^2\) |
</figcaption> | </figcaption> | ||
</figure> | </figure> | ||
Line 439: | Line 435: | ||
<p> | <p> | ||
- | As expected, increasing the cell density | + | As expected, increasing the cell density increases the conductance. When the cell density is increased by 20%, the conductance is increased by 65% (from 2.7e-13 a.u. to 4.4e-13 a.u.). Increasing the cell density thus greatly improves our signal. Furthermore, we expect that there is less sensitivity to the random behaviour of the cell placement, since there is a larger sample size. However, we cannot strongly make this statement, since we only have 5 data points at larger densities (mean uncertainty of 2.7%). Another very important conclusion and recommendation for the lab is that the cell density should be kept constant, as small changes in cell density have a strong effect on the signal. It should be noted that for very high cell densities our model might not work, since we did not account for physical interactions between the cells and/or curli. |
</p> | </p> | ||
<br> | <br> | ||
- | <h5>Influence of | + | <h5>Influence of CsgB induction strength</h5> |
<p> | <p> | ||
- | The most important question of all is: Will our system work, and under what conditions? To answer this question we have done the exact same simulation | + | The most important question of all is: Will our system work, and under what conditions? To answer this question we have done the exact same simulation for the gene level and the cell level as elsewhere, except with the only difference that we halved the promoter strength of CsgB. This simulates less CsgB protein production, which corresponds to less TNT/DNT present in the system. The results are shown in figure 8. |
</p> | </p> | ||
<figure> | <figure> | ||
- | <img src="https://static.igem.org/mediawiki/2014/6/6d/TUDelft2014_Colony_ActivationStrength.png" width=" | + | <img src="https://static.igem.org/mediawiki/2014/6/6d/TUDelft2014_Colony_ActivationStrength.png" width="60%" height="60%"> |
<figcaption> | <figcaption> | ||
- | Figure 8: The conductance of our chip ( \( 500\mu m | + | Figure 8: The conductance of our chip ( \( 500\mu m \ by \ 500\mu m \) as function of time. Two different activation strengths have been simulated. The red lines (same as in figure 6 and 7) show a 100% activated CsgB promoter. The blue lines show the results for a promoter that is activated for 50%.</figcaption> |
</figure> | </figure> | ||
Line 458: | Line 454: | ||
<p> | <p> | ||
- | + | From figure 8 we conclude that the induction strength of the CsgB promoter has an influence on the conductance of our system. Unfortunately, the influence is not as big as we had hoped. The curves are near to each other. Especially for longer times, the differences are barely larger than the uncertainty due to cellular placement on the chip. Comparing these differences to the differences in figure 7 and we conclude that it will be very hard to distinguish between a small increase in cell density or an increase in TNT/DNT. From 3 hours on, the relative differences between the mean of the two curves is less than 20% in figure 8. However, there is some good news. The differences between the red and blue lines are largest in the regime where there is a steep increase in conductance. At t= 1 hour, the red curves have a 2.5 times higher conductance than the blue curves. Furthermore, the red lines transition earlier to a linear increase in conductance than the blue lines. So, when the CsgB promoter is stronger, the system transitions earlier to a linear increase in conductance. | |
</p> | </p> | ||
Line 466: | Line 462: | ||
<h3>Recommendations for product design and wet lab</h3> | <h3>Recommendations for product design and wet lab</h3> | ||
<p> | <p> | ||
- | There are a couple of recommendations we have | + | There are a couple of recommendations we have for the design of the chip: |
<ul> | <ul> | ||
<li> | <li> | ||
- | + | Based on figure 6, we recommend to decrease the distance between the electrodes. This will increase the conductance without increasing the uncertainty. From the shape of the curve, we expect that we do not have to wait very long (only a couple of hours) to do a measurement. After a steep increase in conductance, the increase in conductance will be relatively small in time. Furthermore, the uncertainty due to the placement of our cells increases in time. | |
</li> | </li> | ||
<li> | <li> | ||
- | + | Based on figure 7, we recommend high cell density for increased signal strength of our system. However, it is crucial that the cell density is kept constant throughout the measurement. Cell density influences the conductance significantly and when the cell density is not kept constant, it will influence the conductance measurements in such a way that an increase or decrease in conductance can not only be attributed to an increase or decrease in DNT any longer. | |
</li> | </li> | ||
<li> | <li> | ||
- | From figure 8 we | + | From figure 8, we learned that we have to be very careful with our measurement time in order to be able to draw conclusions about the concentration of TNT/DNT. The influence of the induction strength of the CsgB promoter is very small and its influence decreases after the initial amount of CsgA protein have formed curli. A recommendation for the wet lab is to increase the waiting time prior to induction of the promoter and thereby increasing the initial amount of CsgA protein. This will increase the relative differences in conductance between different induction strengths of the CsgB promoter. In our model, this increase in relative differences in conductance happens between 0 and 2.5 hours. <br> |
+ | The time this increase in relative differences in conductance happens, is strongly dependent on the parameter k in our <a href="https://2014.igem.org/Team:TU_Delft-Leiden/Modeling/Curli/Gene#simplifiedgenelevel">simplified gene model</a>. For our model, we could fit this parameter to conductance curves obtained in the wet lab. Measuring conductance until observing a linear increase in time will give the most useful information for obtaining the inducer concentration, as the time of this transition depends on the strength of induction. | ||
</li> | </li> | ||
</ul> | </ul> | ||
Line 483: | Line 480: | ||
<h3> References </h3> | <h3> References </h3> | ||
- | |||
<p> | <p> | ||
- | + | [1] C.W. Helstrom, "Probability and Stochastic Processes for Engineers", Macmillan Publishing Company, 1984. | |
+ | </p> | ||
+ | <p> | ||
+ | [2] N. Kumar, "Comprehensive Physics XII", Laxmi Publications, 2003. | ||
+ | </p> | ||
+ | <p> | ||
+ | [3] G.B. Arfken & H.J. Weber, "Mathematical Methods for Physicists Fifth Edition", Academic Press, 2000. | ||
</p> | </p> | ||
- | |||
- | |||
</div> | </div> | ||
</body> | </body> |
Latest revision as of 22:55, 17 October 2014
Colony Level Modeling
Now that we determined values for \(\rho_{curli}\) and \(r_{cond}\) at the cell level, we can finally predict if our system works as expected and capture the dynamics of our system. The product we aim for is a chip where two parallel electrodes are a distance w apart. Between the electrodes, cells will grow and start building curli in the presence of an inducer. Then, we will measure the conductance of the resulting biofilm, which is related to the amount of inducer. Since even with bound gold nanoparticles the conductivity of the curli is very low, the chip is designed such that the electrodes are as long as possible.
For the modeling, we can make some approximations. Since the cells are grown on a chip, we assume that the cells and curli grow on a surface. This reduces our problem from 3D to 2D. This saves much computational time and memory. For this model, we take a chip of 500 by 500 µm. The electrodes are placed parallel to the y axis on x = 20 µm and x = 480 µm. The next approximation is that the cells are already present when they are induced by DNT/TNT, we neglect cell growth. In our model, E. coli are present with a density of \(\rho_{cell}\). Furthermore, we assume there is no spatial correlation between the cells; hence we place them at random on our chip. The cell density we use is \( \ 2 \cdot 10^4 \) cells per \( mm^2 \). We would like to model higher cell densities and larger chips. However, the memory cost of the solution increases with the amount of cells squared and, even when the code is neatly vectorized, the computational time increases drastically.
Firstly, we want to prove that our system works as expected. So, we want to predict if a conductive path between the two electrodes arise at a certain point in time and at which time this happens. Secondly, we not only want to answer the question if our system works as expected with a yes or no answer, but we also want to make quantitative predictions about the resistance between the two electrodes of our system in time. We do this by modeling the curli growth on the colony level; each cell is now visualized and has curli growth. Now, we have come up with two different approaches to answer these questions:
- Firstly, we let the cells increase their conductive radius in time, according with our findings on the cellular level, see figure 1. A connection is created from one electrode to the other electrode when there is a conductive path between them. Conductive paths consists of cells that have a connection between each other; cells connect when there is an overlap between their conductive radius. This problem is very similar to problems in percolation theory. From this, we can make conclusions about how our system works in an experimental setting.
- Secondly, we not only want to answer the question if our system works as expected with only a yes or no answer, but we also want to make quantitative predictions about the resistance between the two electrodes of our system in time. Therefore, we used graph theory to translate the cells on the chip to a graph and used an algorithm from graph theory to calculate the resistance between the two electrodes. The conductance between the cells is computed from an integral that we have set up starting at equation 1 and resulting in equation 18.
-
Gene Level Modeling
-
Cell Level Modeling
-
Colony Level Modeling
-
Critical Reflection on our Model
Curli Module
Percolation
We have designed our chip as a 500 by 500 µm square with an electrode on the left and right side. On this chip, we place cells randomly with a density of \(\rho_{cell}\). Subsequently, we increase the conductive radius of each cell in time, corresponding with our findings on the cellular level, see figure 1. A connection is created from one electrode to the other electrode when there is a conductive path between them. Conductive paths consists of cells that have a connection with each other. Cells have a connection with each other when there is an overlap between their conductive radii. We have programmed this by calculating the distances of all cells with all other cells and then calculate if that distance is greater than the respective conductive radius of each cell added to each other. A simulation of our resulting model is shown in figure 2. Percolation is computed by applying an algorithm that can find clusters of connected cells. When one of the clusters connects both electrodes, there is percolation.
We have stochasticity in our model, as we place the cells randomly with a density of \(\rho_{cell}\) on the chip. Therefore, we simulated our model 100 times and for each point in time we checked if there was percolation. We will only get a yes (1) or no (0) response. This enables us to find the chance of percolation at each time point, shown in figure 3 as the yellow line. The yellow line shows a sharp transition between 1.5 and 2 hours. Since this is a Bernoulli process [1], the variance is exactly equal to p(1-p). The variance must be as low as possible to get reliable measurement results. This is achieved when the transition from no percolation to percolation is as sharp as possible.
At first we assumed that \(r_{cond}\) is the same for each cell at each point in time (figure 1 red line). However, figure 1 shows that there clearly is some cellular variation in \(r_{cond}\). Therefore, we added a new feature to our model; the conductive radius of each cell can now deviate from the mean \(r_{cond}\) with the standard deviation as found in figure 1. We simulated our new model again 100 times and for each point in time we checked the chance of percolation, see figure 3 as the blue line. Fortunately, the resulting curve is very similar to the curve without variation in \(r_{cond}\) (yellow line). This means that cellular variation has little influence on the chance of percolation at each point in time. Therefore, the results of our model are robust to cellular variation and it is likely that many factors that could increase the cellular variation, e.g. different CsgA or CsgB protein production rates, are relatively unimportant.
Influence of the chip geometry on the point of percolation
To further investigate the point of percolation we have varied the shape of our chip. We have decreased the relative distance between the electrodes by making our chip 250 µm x 500 µm, where the electrodes are 250 µm apart. From the result, shown in figure 4, it can be seen that our system behaves in correspondence with a percolation problem. The system is smaller, therefore the transition toward percolation is less sharp. This suggests that we want to increase the area size of our system. A larger area results in a shaper transition, thus a lower uncertainty. Other simulations with a chip of 1000 µm x 500 µm show a sharper transition.
Influence of the promoter strength on the moment of percolation
As we want our system to be usable as a biosensor, it has to be strongly dependent on the analyte concentration, and therefore the CsgB production rate. To verify this is the case, we have run the same gene and cell level simulations as before, with the same parameters, including the critical density. The only exception is that the CsgB production rate is reduced by 50%. (\(p_B = 6.5 \cdot 10^{-14} M/s\) instead of (\(p_B = 1.3 \cdot 10^{-13} M/s \) ). The result is shown in figure 5.
From the figure, we see that there is a very distinguishable difference between the two lines. First of all, the moment of percolation is much later (4.5 hours as opposed to 1.5 hours). Equally important is that the transition from no percolation to percolation is much less sharper.
Resistance
To calculate the conductance (which is the inverse of the resistance) as function of time, we repeat the following steps:
- Place the cells on the chip.
- Compute the conductance between the cells.
- Compute the conductance between the electrodes.
Compute the conductance between the cells
First, we have to get a quantitative measure for the conductance between two cells. To do this, we will quantify the overlap of two conducting spheres, where we assumed that the conducting spheres represent cells surrounded by curli filaments. We subdivide the overlapping region in infinitesimal volumes \(dV\). The infinitesimal conductance of such an infinitesimal volume is given by:
$$ d \sigma (y) = \ \frac{\rho_1}{r_1} dV \frac{\rho_2}{r_2} dV \tag{1}$$The factor \( 1/r \) is introduced to account for the conductance of the wires itself, which is inversely proportional to the length of the conducting wire [2]. Further away from the cell, the wires need a longer distance to go to the cell. Since we want to know the strength of the connection between the cells, we have to include this factor. For a straight line this is inversely proportional to the distance. For a single curli fibril, this relation does not hold. However, we assume that the curli density is high, thus there are many connections between the curli. Then there is a pathway from the origin to \( r \) roughly proportional to the distance from the cell. To find the total conductance, we integrate on both sides. To account for the fact that both volume elements \(dV\) are the same, we make use of the Dirac-delta function \(\delta_3\) [3]. This gives us the following:
$$ \sigma (y) = \int{ \frac{\rho_1(\vec{r_1})\rho_2(\vec{r_2})}{r_1 r_2}\delta_3(\vec{r_2}-f(\vec{r_1}))d^3\vec{r_1}d^3\vec{r_2}} \tag{2} $$The Dirac delta allows us to remove the \(\vec{r_2}\) dependence by expressing these in \(\vec{r_1}\). The still undetermined relation between \(\vec{r_1}\) and \(\vec{r_2}\) is given by \(\vec{r_2} = f(\vec{r_1})\). Applying this removes one of the two volume integrations. Using spherical coordinates, the resulting single volume integration can be written as:
$$ \sigma (y) = \int_{r_0}^{r_{max}} \int_0^{\theta_{max}(r)} \int_0^{2\pi} \rho(r_1)\rho_2(f(r_1))\frac{r_1}{f(r_1)} \sin(\theta_1) d\phi_1 d\theta_1 dr_1 \tag{3} $$Here we have made use of the fact that the density \(\rho\) is only dependent on \(r\) and not on \(\phi\) and \(\theta \). The integral over \(\phi_1\) is trivial and gives us a multiplication factor of \(2 \pi\):
$$ \sigma (y) = \ 2 \pi \int_{r_0}^{r_{max}} \int_0^{\theta_{max}(r)} \rho(r_1)\rho_2(f(r_1))\frac{r_1}{f(r_1)} \sin(\theta_1) d\theta_1 dr_1 \tag{4} $$Now that we have reduced our integration to two dimensions, we will work out \(f(\vec{r_1})\). To do this, we introduce the vector from the origin of cell 1 to the origin of cell 2, \(\vec{y}\). This allows us to express \(\vec{r_2}\) in terms of \(\vec{y}\) and \(\vec{r_1}\):
$$ \vec{r_2} = \ \vec{y} - \ \vec{r_1} = \begin{bmatrix}y \\0\\ \end{bmatrix} - \begin{bmatrix} r_1 \cos(\theta_1) \\r_1 \sin(\theta_1)\\ \end{bmatrix} \tag{5} $$Now it is straightforward to express \(r_2\) in terms of \(y\), \(r_1\) and \(\theta_1\):
$$ r_2 = \ |\vec{r_2}| = \ \sqrt{(y - r_1 \cos(\theta_1))^2 + \ r_1^2 \sin^2(\theta_1)} \tag{6} $$Plugging this in yields the following integral:
$$ \sigma (y) = \ 2 \pi \int_{r_0}^{r_{max}} \int_0^{\theta_{max}(r)} \frac{\rho(r_1)\rho_2 \left( \sqrt{(y - r_1 \cos(\theta_1))^2 + r_1^2 \sin^2(\theta_1)}\right) r_1 \sin(\theta_1)}{ \sqrt{(y - r_1 \cos(\theta_1))^2 + r_1^2 \sin^2(\theta_1)}} d\theta_1 dr_1 \tag{7} $$We will now have a closer look at the boundary values for \(r_1\) and \(\theta_1\). We want to integrate over the entire space. Therefore, \( \theta(max) = \pi \) and \( r_{max}=\infty \). By introducing no cut-off radius, we are able to take into account the possibility of having by chance a very large conductive radius. Here we have approximated our cells as points in space. Hence \( r_0 =0 \).
We will now use that the curli density can be described as (see section Cell Level Model):
$$ \rho(r) = \ C_{1}e^{-\frac{r}{C_{2}}} + C_{3}e^{-\frac{r}{C_{4}}} \tag{8} $$For simplicity we demonstrate what the formula would look like when only one exponential term is present. Later we will show how you can use this to get an expression for the entire formula.
$$ \rho(r) = \ C_{1}e^{-\frac{r}{C_{2}}} \tag{9} $$Plugging in the boundary values and our expression for \(\rho(r)\), we find the following expression for the conductance between two cells:
$$ \sigma (y) = \ 2 \pi C_{1}^2 \int_{0}^{\infty} \int_0^{\pi} \frac{e^{-\frac{r_1}{C_{2}}} e^{-\frac{ \sqrt{(y - \ r_1 \cos(\theta_1))^2 + \ r_1^2 \sin^2(\theta_1)}}{C_{2}}} r_1 \sin(\theta_1)}{\sqrt{(y - r_1 \cos(\theta_1))^2 + r_1^2 \sin^2(\theta_1)}} d\theta_1 dr_1 \tag{10} $$This integral looks very complicated, but don't panic! It can algebraically be simplified with some substitutions. We can rewrite this integral by moving all terms independent of \( \theta \) out of the integral over \(\theta_1\). Furthermore, using that \( \sin^2 (\theta_1) + \cos^2(\theta_1) = 1 \) we get.
$$ \sigma (y) = \ 2 \pi C_{1}^2 \int_{0}^{\infty} r_1 e^{-\frac{r_1}{C_{2}}} \int_0^{\pi} \frac{e^{-\frac{ \sqrt{y^2+r_1^2-2yr_1 cos( \theta_1 ) }}{C_{2}}} \sin(\theta_1)}{ \sqrt{y^2+r_1^2-2yr_1 \cos( \theta_1 ) }} d\theta_1 dr_1 \tag{11} $$Now we must recognize that we can substitute \( x= cos(\theta_1) \) such that \( dx = -\sin(\theta_1) d\theta_1 \). This results in:
$$ \sigma (y) = - \ 2 \pi C_{1}^2 \int_{0}^{\infty} r_1 e^{-\frac{r_1}{C_{2}}} \int_1^{-1} \frac{e^{-\frac{ \sqrt{y^2+r_1^2-2yr_1 x }}{C_{2}}}}{\sqrt{y^2+r_1^2-2yr_1 x }} dx dr_1 \tag{12} $$In the second integral we recognize something of the form \( \int \frac{e^{-\sqrt{a+bx}}}{C_2\sqrt{a+bx}} dx \) with \( a= \frac{y^2+r_1^2}{C^2_2} \) and \(b=-\frac{2yr_1}{C^2_2} \). Substituting \( h= \sqrt{a+bx} \) with \( dx= \frac{2h}{b} dh \) yields:
$$ \int_1^{-1} \frac{e^{-\sqrt{a+bx}}}{C_2\sqrt{a+bx}} dx = \frac{2}{bC_2} \int_{\sqrt{a+b}}^{\sqrt{a-b}} e^{-h} dh= \frac{-2}{bC_2} (e^{-\sqrt{a-b}}- \ e^{-\sqrt{a+b}})$$Now \(a\) and \(b\) can be substituted:
$$ \int_1^{-1} \frac{e^{-\sqrt{a+bx}}}{C_2\sqrt{a+bx}} dx = \frac{C_2}{yr_1} \left( e^{-\frac{\sqrt{y^2+r_1^2+2yr_1}}{C_2}} - e^{-\frac{\sqrt{y^2+r_1^2-2yr_1}}{C_2}} \right)$$Hence, the entire integral now becomes:
$$ \sigma (y) = \frac{ 2 \pi C_{1}^2 C_2 }{y} \int_{0}^{\infty} e^{-\frac{|y-r_1|+r_1}{C_2} } - e^{-\frac{y+2r_1}{C_2} } dr_1 \tag{13} $$Solving the second integral is fairly easy:
$$ \sigma (y) = \frac{ 2 \pi C_{1}^2 C_2 }{y} \int_{0}^{\infty} e^{-\frac{|y-r_1|+r_1}{C_2} }-e^{-\frac{y+2r_1}{C_2} } dr_1 = \frac{ 2 \pi C_{1}^2 C_2 }{y} \left( \int_{0}^{y} e^{-\frac{y}{C_2}} dr_1 +\int_{y}^{\infty} e^{-\frac{2r_1-y}{C_2}} dr_1 -e^{\frac{-y}{C_2}}\int_0^{\infty} e^{-\frac{2r_1}{C_2} } dr_1 \right) \tag{14} $$Which brings us to the final result:
$$ \sigma (y) = \ 2 \pi C_{1}^2 C_2 e^{-\frac{y}{C_2}} \tag{15} $$The same derivation has also been done by us for the case that \( \rho_1(r) = \ C_{1}e^{-\frac{r}{C_{2}}} \) and \( \rho_2(r) = \ C_{3}e^{-\frac{r}{C_{4}}} \). The conductance between the two electrodes is then:
$$ \sigma (y) = \ \frac{4 \pi C_{1}C_3 C_2^2 C_4^2}{y \left( C_2^2 - C_4^2 \right)} \left( e^{-\frac{y}{C_2}} -e^{-\frac{y}{C_4}} \right) \tag{16} $$In our case \( \rho_{1}= \rho_{2} = \rho_a + \rho_b \), with \( \rho_a = C_1 e^{-\frac{r}{C_2}} \) and \( \rho_b = C_3 e^{-\frac{r}{C_4}} \). We can use the linearity of the system and using equation 1:
$$ d \sigma (y) = \ \frac{\rho_{1}}{r_1} dV \frac{\rho_2}{r_2} dV = \ \frac{\rho_{a}}{r_1} dV \frac{\rho_a}{r_2} dV + \ \frac{\rho_{b}}{r_1} dV \frac{\rho_b}{r_2} dV + 2* \frac{\rho_{a}}{r_1} dV \frac{\rho_b}{r_2} dV\tag{17} $$These will form three integrals in the same form as we have previously derived! The final result then becomes:
$$ \sigma (y) = \ 2 \pi \left( C_{1}^2 C_2 e^{-\frac{y}{C_2}} + C_{3}^2 C_4 e^{-\frac{y}{C_4}} + \frac{4 C_{1}C_3 C_2^2 C_4^2}{y \left( C_2^2 - C_4^2 \right)} \left( e^{-\frac{y}{C_2}} -e^{-\frac{y}{C_4}} \right) \right) \tag{18}$$Results
Now, we use graph theory to translate the cells on the chip to a graph and use an algorithm from graph theory to calculate the resistance between the two electrodes.
Influence of the chip size
We have calculated the conductance as function of time for different dimensions of our plate. We varied the distance between the electrodes between 210, 460 and 960 \( \mu m \). The length of the electrodes is kept at \( 500 \mu m\). The result is shown in figure 6.
From figure 6 we draw a couple of conclusions:
- First of all, there is a very strong trend in the red lines. From 0-2 hours, the conductance is increasing rapidly. We have already seen from the gene level modeling that this is the result of rapid curli growth due to the abundance of CsgA at t=0 hours. When all initial CsgA proteins have formed curli, the increase in curli is linear with time and so is the conductance. This is unexpected, since from the resistor example in percolation theory, an exponential increase was expected, see the percolation theory section. From these results we conclude that it is not necessary to wait a very long time to see any change in conductivity in our system. The conductivity at 10 hours is barely twice as large as the conductivity at 2 hours.
- When the electrodes are positioned further away, the conductance decreases inversely proportional. An increase from \( 210 \mu m \) to \( 460 \mu m \) (factor 2.2) results in a decrease in conductivity from \( 6.1e-13 \) a.u. to \(2.6e-13\) a.u. (factor \(2.3^{-1}\). However, the lines maintain their same shapes.
- The relative uncertainty of the green and red curves is not significantly different. The mean relative uncertainty of the larger chip (red lines) is 3.7 % as opposed to 3.4% for the smaller chip (green lines). The relative uncertainty is smallest at 1:15 hr, where the slope is steepest for both curves (2.6%) and the relative uncertainty increases with time. We haven't obtained a relative uncertainty for when the electrodes were \( 960 \mu m \) apart, as we performed that simulation only once.
Influence of the cell density
Another parameter we investigated is the influence of cell density on the conductivity of the system. From percolation theory we have learned that this has a strong influence on the moment of percolation.
As expected, increasing the cell density increases the conductance. When the cell density is increased by 20%, the conductance is increased by 65% (from 2.7e-13 a.u. to 4.4e-13 a.u.). Increasing the cell density thus greatly improves our signal. Furthermore, we expect that there is less sensitivity to the random behaviour of the cell placement, since there is a larger sample size. However, we cannot strongly make this statement, since we only have 5 data points at larger densities (mean uncertainty of 2.7%). Another very important conclusion and recommendation for the lab is that the cell density should be kept constant, as small changes in cell density have a strong effect on the signal. It should be noted that for very high cell densities our model might not work, since we did not account for physical interactions between the cells and/or curli.
Influence of CsgB induction strength
The most important question of all is: Will our system work, and under what conditions? To answer this question we have done the exact same simulation for the gene level and the cell level as elsewhere, except with the only difference that we halved the promoter strength of CsgB. This simulates less CsgB protein production, which corresponds to less TNT/DNT present in the system. The results are shown in figure 8.
From figure 8 we conclude that the induction strength of the CsgB promoter has an influence on the conductance of our system. Unfortunately, the influence is not as big as we had hoped. The curves are near to each other. Especially for longer times, the differences are barely larger than the uncertainty due to cellular placement on the chip. Comparing these differences to the differences in figure 7 and we conclude that it will be very hard to distinguish between a small increase in cell density or an increase in TNT/DNT. From 3 hours on, the relative differences between the mean of the two curves is less than 20% in figure 8. However, there is some good news. The differences between the red and blue lines are largest in the regime where there is a steep increase in conductance. At t= 1 hour, the red curves have a 2.5 times higher conductance than the blue curves. Furthermore, the red lines transition earlier to a linear increase in conductance than the blue lines. So, when the CsgB promoter is stronger, the system transitions earlier to a linear increase in conductance.
Recommendations for product design and wet lab
There are a couple of recommendations we have for the design of the chip:
- Based on figure 6, we recommend to decrease the distance between the electrodes. This will increase the conductance without increasing the uncertainty. From the shape of the curve, we expect that we do not have to wait very long (only a couple of hours) to do a measurement. After a steep increase in conductance, the increase in conductance will be relatively small in time. Furthermore, the uncertainty due to the placement of our cells increases in time.
- Based on figure 7, we recommend high cell density for increased signal strength of our system. However, it is crucial that the cell density is kept constant throughout the measurement. Cell density influences the conductance significantly and when the cell density is not kept constant, it will influence the conductance measurements in such a way that an increase or decrease in conductance can not only be attributed to an increase or decrease in DNT any longer.
-
From figure 8, we learned that we have to be very careful with our measurement time in order to be able to draw conclusions about the concentration of TNT/DNT. The influence of the induction strength of the CsgB promoter is very small and its influence decreases after the initial amount of CsgA protein have formed curli. A recommendation for the wet lab is to increase the waiting time prior to induction of the promoter and thereby increasing the initial amount of CsgA protein. This will increase the relative differences in conductance between different induction strengths of the CsgB promoter. In our model, this increase in relative differences in conductance happens between 0 and 2.5 hours.
The time this increase in relative differences in conductance happens, is strongly dependent on the parameter k in our simplified gene model. For our model, we could fit this parameter to conductance curves obtained in the wet lab. Measuring conductance until observing a linear increase in time will give the most useful information for obtaining the inducer concentration, as the time of this transition depends on the strength of induction.
References
[1] C.W. Helstrom, "Probability and Stochastic Processes for Engineers", Macmillan Publishing Company, 1984.
[2] N. Kumar, "Comprehensive Physics XII", Laxmi Publications, 2003.
[3] G.B. Arfken & H.J. Weber, "Mathematical Methods for Physicists Fifth Edition", Academic Press, 2000.