Team:TU Delft-Leiden/WetLab/landmine/characterisation

From 2014.igem.org

(Difference between revisions)
Line 47: Line 47:
Using the constructs BBa_K1316003 and BBa_K1316005, different concentrations of 2,4-DNT were tested:
Using the constructs BBa_K1316003 and BBa_K1316005, different concentrations of 2,4-DNT were tested:
 +
 +
<figure>
<img src="https://static.igem.org/mediawiki/2014/c/c8/TUDelft_2014_Fluorescence_measurements_landmine_promoters_correct.png" width="100%" height="100%">
<img src="https://static.igem.org/mediawiki/2014/c/c8/TUDelft_2014_Fluorescence_measurements_landmine_promoters_correct.png" width="100%" height="100%">
 +
<p>
 +
<figcaption>
 +
Figure 1: Fluorescent signal measured on the plate reader.
 +
</figcaption>
 +
</figure>
 +
 +
 +
Line 78: Line 88:
</figcaption>
</figcaption>
</figure>
</figure>
-
 
-
 

Revision as of 17:59, 14 October 2014

Module Landmine Detection - Characterization


click to return to the Module Landmine Detection


As already mentioned, the promoters found to be activated in presence of several chemical compounds that can leak from land mines (ybiJ and yqjF) were coupled to the expression of the fluorescent protein mKate2.

Assays

The different assays used to test our Land Mine BioBricks are:

  • Plate Reader

  • Microscopy

  • FACS

  • Plate Reader

    A plate reader is a machine designed to handle samples on 6-1536 well format microtiter plates for the measuring of physical properties such as absorbance, fluorescence intensity, luminescence, time-resolved fluorescence, and fluorescence polarisation. Concerning this module, the plate reader device was used for the measurement of fluorescence intensity generated by cells carrying the BioBricks designed to detect land mines. The final protocol developed for Plate reader analysis for this module can be found at

    LINK TO PROTOCOLS

    Results - Plate Reader

    Using the constructs BBa_K1316003 and BBa_K1316005, different concentrations of 2,4-DNT were tested:

    Figure 1: Fluorescent signal measured on the plate reader.

    The BioBricks showed an increasing fluorescent signal over time when they were induced with DNT. When non-induced (0mg/L DNT), the constructs showed no clear increase in fluorescent signal. The BioBrick BBa_K1316003 (sample B on the Figures) showed a much higher response than BBa_K1316005 (sample C on the Figures), hence, the yqjF promoter responds better to DNT than the ybiJ promoter, consistently with the literature [1]. The non-induction of the negative control (sample D on the Figures) indicates that it is the presence of the promoter that generates the signal in front of the presence of DNT.

    Microscopy

    FACS

    Fluorescence-activated cell sorting (FACS) is a specialised type of flow cytometry that allows the separation of individual cells based on the specific light scattering and fluorescent characteristics of each cell. Using FACS, information can be known of the size, shape and fluorescence of individual cells, therefore, it is a technique that can be used to observe the fluorescent response of our Landminde detection BioBricks in front of DNT.


    The FACS technology allows us to see that, per cell, more fluorescence is produced by the construct BBa_K1316003 after several hours of their induction with DNT.

    Figure 2: Fluorescent signal emited by cells carrying constitutively expressed mKate2 (positive control), two paralel samples of the construct BBa_K1316003 (Sample 1 and 2), and empty cells not carrying any BioBrick (negative control) 2 hours after induction (left) and 6 hours after induction (right).

    References

    [1] S. Yagur-Kroll, S. Belkin et al., “Escherichia Coli bioreporters for the detection of 2,4-dinitrotoluene and 2,4,6-trinitrotoluene”, Appl. Microbiol. Biotechnol. 98, 885-895, 2014.

    Top
    facebook twitter