Team:ETH Zurich/labblog/20140908meet

From 2014.igem.org

(Difference between revisions)
(Week 16)
 
(6 intermediate revisions not shown)
Line 1: Line 1:
-
<html><article class="mix carousel meetings quorum milli" date="20140908" id="week16"></html>
+
<html><article class="mix carousel meetings" date="20140908" id="week16"></html>
-
== Week 16 ==  
+
== Week 16 : choosing an AHL pair, improving diffusion ==  
==== Monday 8th September ====
==== Monday 8th September ====
-
* We have enough crosstalk results to decide which pair of quorum sensing systems we will use. Cross-talk experiments setup is described in <html> <a targetid="cross-talk" id="insidelink" href="https://2014.igem.org/Team:ETH_Zurich/blog#cross-talk"> this article </a> </html>. Until now we thought Lux was crosstalking too much with las and tried to improve the pair Las-Rhl. However we realized today that Rhl is difficult to improve and that our induction curves of Las and Lux are good enough, since Las is never responding to lux-HSL and we only have to be in a range of las-HSL concentrations that is below 10 nM to avoid Lux responding to las-HSL.
+
* We have enough crosstalk results to decide which pair of quorum sensing systems we will use : Las and Lux. See <html> <a id='insidelink' targetid='ctresults' href="https://2014.igem.org/Team:ETH_Zurich/blog#ctresults"> this article </a> </html> for more details.
-
[[File:ETH Zurich cosstalk.PNG|center|800px|thumb|Summary of results from cross-talk experiments]]
+
-
* Diffusion experiment (trying to have a correlation between channel length and time of fluorescence, having cells at the end of a channel and adding pure HSL at the other end of the channel, see <html> <a class="all" id="insidelink" href="https://2014.igem.org/Team:ETH_Zurich/blog#diffusionexp"> this article </a> </html> for more details on the setup) : We tried lower concentrations of pure HSL and the wells start shining at different moments, but we still don't have any correlation between channel length and starting time of fluorescence, because our chip seems to be leaky and some wells dried completely. However, this experiment enables us to check that fluorescence appears after a reasonable time and that channel length probably doesn't influence this time too much.  
+
* Diffusion experiment (trying to have a correlation between channel length and time of fluorescence, having cells at the end of a channel and adding pure HSL at the other end of the channel, see <html> <a id='insidelink' targetid='diffusionexp' href="https://2014.igem.org/Team:ETH_Zurich/blog#diffusionexp"> this article </a> </html> for more details on the setup) : We tried lower concentrations of pure HSL and the wells start shining at different moments, but we still don't have any correlation between channel length and starting time of fluorescence, because our chip seems to be leaky and some wells dried completely. However, this experiment enables us to check that fluorescence appears after a reasonable time and that channel length probably doesn't influence this time too much.  
* On the modeling side, we are not able to retrieve diffusion coefficient of HSL from this diffusion experiment but we can use a parameter from literature.
* On the modeling side, we are not able to retrieve diffusion coefficient of HSL from this diffusion experiment but we can use a parameter from literature.

Latest revision as of 19:05, 11 October 2014