Team:TU Delft-Leiden/WetLab/landmine/characterisation

From 2014.igem.org

(Difference between revisions)
 
(42 intermediate revisions not shown)
Line 6: Line 6:
                
                
  <!--PAGE CONTENT----------------->  
  <!--PAGE CONTENT----------------->  
-
<h2> Module Landmine Detection - Characterization</h2>
+
<h2>Module Landmine Detection &ndash; Characterization</h2>
-
<p>
+
-
<br>
+
<p>In the wet lab, we made constructs containing the fluorescent protein mKate2 regulated by the ybiJ and yqjF promoters, which are thought to be activated with some chemicals such as 2,4-DNT or 1,3-DNB. Here you can find information with respect to the characterization of the BioBricks for the Landmine Detection module.
-
<p>
+
   
-
click to return to the <a href="https://2014.igem.org/Team:TU_Delft-Leiden/WetLab/landmine"> <b> Module Landmine Detection </b> </a>
+
<div class="tableofcontents">
-
</p>
+
 
-
<br>
+
        <ul>
 +
            <a href="/Team:TU_Delft-Leiden/WetLab/landmine">Module Landmine Detection</a>
 +
<ul>
 +
            <li><a href="/Team:TU_Delft-Leiden/WetLab/landmine/theory">Context</a></li>
 +
            <li><a href="/Team:TU_Delft-Leiden/Project/Life_science/landmine/integration">Integration of Departments</a></li>
 +
            <li><a href="/Team:TU_Delft-Leiden/WetLab/landmine/cloning">Cloning</a></li>
 +
            <li>Characterization</li>
 +
        </ul>
 +
    </div>
-
As already <a href="/Team:TU_Delft-Leiden/WetLab/landmine/theory">mentioned</a>, the promoters found to be activated in presence of several chemical compounds that can leak from land mines (ybiJ and yqjF) were coupled to the expression of the fluorescent protein mKate2.
+
    <p>As already <a href="/Team:TU_Delft-Leiden/WetLab/landmine/theory">mentioned</a>, the promoters found to be activated in presence of several chemical compounds that can leak from land mines (ybiJ and yqjF) were coupled to the expression of the fluorescent protein mKate2.</p>
-
<h2> Assays </h2>
+
    <div class="clear"></div>
 +
<h3> Assays </h3>
<p>
<p>
The different assays used to test our Land Mine BioBricks are:
The different assays used to test our Land Mine BioBricks are:
 +
<ul>
  <li><a href="/Team:TU_Delft-Leiden/WetLab/landmine/characterisation#LDplate_reader"><p>Plate Reader </p>
  <li><a href="/Team:TU_Delft-Leiden/WetLab/landmine/characterisation#LDplate_reader"><p>Plate Reader </p>
-
        </a>
 
-
</li>
 
-
 
-
 
-
<li><a href="/Team:TU_Delft-Leiden/WetLab/landmine/characterisation#LDmicroscopy"><p>Microscopy </p>
 
         </a>
         </a>
</li>
</li>
Line 34: Line 38:
         </a>
         </a>
</li>
</li>
 +
</ul>
 +
</p>
 +
<br>
 +
<p>
 +
The different constructs used are:
 +
<ul>
 +
<li> p[F]::mKATE, also referred here as LD2, which corresponds to BioBrick BBa_K1316003  </li>
 +
<li> p[J]::mKATE, also referred here as LD3, which corresponds to BioBrick BBa_K1316005  </li>
 +
<li> p[F] incl. N-enzymes, also referred here  as LD4, which corresponds to BioBrick BBa_K1316007  </li>
 +
<li> p[J] incl. N-enzymes, also referred here as LD5, which corresponds to BioBrick BBa_K1316008  </li>
 +
<li> p[F]::mKATE p[J]::mKATE, also referred here  as LD6, which corresponds to BioBrick BBa_K1316009  </li>
 +
</ul>
 +
 +
</p>
 +
<br>
<a name="LDplate_reader"></a>  
<a name="LDplate_reader"></a>  
-
<h3> Plate Reader </h3>
+
<h4> Plate Reader </h4>
<p>
<p>
-
A plate reader is a machine designed to handle samples on 6-1536 well format microtiter plates for the measuring of physical properties such as absorbance, fluorescence intensity, luminescence, time-resolved fluorescence, and fluorescence polarisation. Concerning this module, the plate reader device was used for the measurement of fluorescence intensity generated by cells carrying the BioBricks designed to detect land mines. The final protocol developed for Plate reader analysis for this module can be found at
+
A plate reader is a machine designed to handle samples on 6-1536 well format microtiter plates for the measuring of physical properties such as absorbance, fluorescence intensity, luminescence, time-resolved fluorescence, and fluorescence polarisation. Concerning this module, the plate reader device was used for the measurement of fluorescence intensity generated by cells carrying the BioBricks designed to detect land mines. The final protocol developed for Plate reader analysis for this module can be found by clicking on<a href="https://static.igem.org/mediawiki/2014/f/f4/Delft2014_PlatereaderLD.pdf"> this link</a>.</p>
-
<h2> LINK TO PROTOCOLS </h2>
+
</b>
 +
<br>
 +
<h4> Results - Plate Reader </h4>
 +
<p>
 +
Using the different final Landmine detection constructs LD2-6, different concentrations of 2,4-DNT were tested (figure 1). 2,4-DNT, due to safety reasons, was bought in liquid solution dissolved in acetonitrile. To test that the compound triggering the response of the promoters is 2,4-DNT and not acetonitrile, the 0 mg/L 2,4-DNT solution was prepared with the same concentration of acetonitrile contained in the most concentrated 2,4-DNT solution.
 +
</p>
 +
<br>
-
<h3> Results - Plate Reader </h3>
+
<p>The fact that the positive control (constitutively expressed mKate2) presents a clear fluorescence signal at 0 and 50 mg/L, but not at 100 mg/L indicates that high concentrations of 2,4-DNT are toxic for cells after several hours. The toxic compound seems to be 2,4-DNT and not acetonitrile because the sample at 0 mg/L 2,4-DNT (same acetonitrile concentration as the 100 mg/L 2,4-DNT sample) did not kill the cells. Constructs LD2, LD3 and LD6 as well as LD4 and LD5 with no induction of the N-genes show no clear mKate2 induction over time. Not many conclusions can be drawn form LD2 due to the big standard deviation. However, when the N-genes are induced with L-Rhamnose, the constructs LD4 and LD5 showed a clear increase in fluorescence over time for a concentration of 50 mg/L 2,4-DNT. In this situation, besides, LD5 seems to be more sensitive, as there is less leakage (there is less fluorescence signal at 0 mg/L DNT).
 +
</p>
 +
<br>
 +
<p>
 +
It could still be that at 50 mg/L 2,4-DNT, what triggers the response of the promoters is actually the acetonitrile and not the 2,4-DNT, but that would be strange because at 0 mg/L 2,4-DNT (acetonitrile is 2 times more concentrated than at 50 mg/L 2,4-DNT) the cells survive and there is no fluorescence response.
 +
</p>
 +
<br>
 +
 
 +
<p>
 +
This data suggests that both promoters, ybiJ and yqjF, respond to 2,4-DNT; and that the presence of the N-genes is of high importance for this response. Hence, we conclude that the two best BioBricks for Landmine detection are (in this order) LD5 (p[J] incl. N-enzymes) and LD4 (p[F] incl. N-enzymes), and in order to obtain a good result the N-genes must be expressed.
-
Using the constructs BBa_K1316003 and BBa_K1316005, different concentrations of 2,4-DNT were tested:
 
<figure>
<figure>
-
<img src="https://static.igem.org/mediawiki/2014/c/c8/TUDelft_2014_Fluorescence_measurements_landmine_promoters_correct.png" width="100%" height="100%">
+
<img src="https://static.igem.org/mediawiki/2014/b/bf/TUDelft_2014_Fluorescence_LD_final.png" width="100%" height="100%">
<p>
<p>
<figcaption>
<figcaption>
-
Figure 1: Fluorescent signal measured on the plate reader.
+
Figure 1: Fluorescence signal measured on the plate reader. Positive control: constitutively expressed mKate2. Negative control: Empty cells carrying no BioBrick
</figcaption>
</figcaption>
</figure>
</figure>
Line 58: Line 91:
-
 
+
<a name="LDfacs"></a>
-
 
+
<h4> FACS </h4>
<p>
<p>
-
The BioBricks showed an increasing fluorescent signal over time when they were induced with DNT. When non-induced (0mg/L DNT), the constructs showed no clear increase in fluorescent signal.
+
Fluorescence-activated cell sorting (FACS) is a specialised type of flow cytometry that allows the separation of individual cells based on the specific light scattering and fluorescent characteristics of each cell. Using FACS, information can be attained of the size, shape and fluorescence of individual cells, therefore, it is a technique that can be used to observe the fluorescent response of our Landminde detection BioBricks in front of DNT.
-
The BioBrick BBa_K1316003 (sample B on the Figures) showed a much higher response than BBa_K1316005 (sample C on the Figures), hence, the yqjF promoter responds better to DNT than the ybiJ promoter, consistently with the literature [1].
+
</p>
-
The non-induction of the negative control (sample D on the Figures) indicates that it is the presence of the promoter that generates the signal in front of the presence of DNT.
+
<br>
 +
<p>The FACS technology was used to test the LD2 (p[F]::mKATE) construct. Cultures of this construct were induced with 50 mg/L 2,4-DNT. Aliquots of the culture were taken after 2 and 6 hours; centrifuged and resuspended in PBS solution to eliminate the 2,4-DNT and the acetonitrile; and were then analysed at the FACS machine. At the same time, a strain constitutively expressing mKate2 and an empty strain were used as positive and negative controls respectively. Two cultures of LD2 were used (samples 1 and 2 in figure 2) in order to get the LD2 data in duplo.  
-
<a name="LDmicroscopy"></a>  
+
</p>
-
<h3> Microscopy </h3>
+
<br>
-
<p>
+
 +
<p> The results of the FACS experiments show that the fluorescent response increases with time after induction and, therefore, it means that the yqjF promoter was activated. Figure 2 contains all the LD2 culture (2 and 6 hours after induction), as well as the positive and negative controls. Figure 3 only contains the LD2 culture (2 and 6 hours after induction) and, hence, it provides a more clear picture of the promoter induction. Unfortunately, no solution was prepared containing acetonitrile and water alone and, therefore, we cannot conclude that the induction was caused by 2,4-DNT as it could have been caused by acetonitrile. Nevertheless, as aforementioned, the plate reader results suggests that 2,4-DNT is more likely to be the inducer of the promoters rather than acetonitrile. 
 +
</p>
 +
<br>
 +
<h4> Results - FACS </h4>
 +
<figure>
 +
<img src="https://static.igem.org/mediawiki/2014/9/98/TUDelft_2014_Few_induction.jpg" width="75%" height="75%">
 +
<figcaption>
 +
Figure 2: Fluorescence signal emitted by cells carrying constitutively expressed mKate2 (positive control), two parallel samples of the construct LD2 (p[F]::mKATE) (Samples 1 and 2), and empty cells not carrying any BioBrick (negative control) 2 hours after induction (left) and 6 hours after induction (right).
 +
</figcaption>
 +
</figure>
-
<a name="LDfacs"></a>
 
-
<h3> FACS </h3>
 
-
<p>
 
-
Fluorescence-activated cell sorting (FACS) is a specialised type of flow cytometry that allows the separation of individual cells based on the specific light scattering and fluorescent characteristics of each cell. Using FACS, information can be known of the size, shape and fluorescence of individual cells, therefore, it is a technique that can be used to observe the fluorescent response of our Landminde detection BioBricks in front of DNT.
 
-
</p>
 
-
<br>
 
-
The FACS technology allows us to see that, per cell, more fluorescence is produced by the construct BBa_K1316003 after several hours of their induction with DNT.
 
<figure>
<figure>
-
<img src="https://static.igem.org/mediawiki/2014/9/98/TUDelft_2014_Few_induction.jpg" width="100%" height="100%">
+
<img src="https://static.igem.org/mediawiki/2014/3/34/ITUDelft_2014_GEM2014_Page_07.jpg" width="75%" height="75%">
-
<img src="https://static.igem.org/mediawiki/2014/4/48/TUDelft_2014_After_6h_induction.jpg" width="100%" height="100%">
+
-
<p>
+
<figcaption>
<figcaption>
-
Figure 2: Fluorescent signal emited by cells carrying constitutively expressed mKate2 (positive control), two paralel samples of the construct BBa_K1316003 (Sample 1 and 2), and empty cells not carrying any BioBrick (negative control) 2 hours after induction (left) and 6 hours after induction (right).
+
Figure 3: Fluorescence signal emitted by cells carrying the construct LD2 (p[F]::mKATE) of two different cultures (Top and Bottom) 2 hours after DNT induction (samples 1 and 2) and 6 hours after DNT induction (samples 1 after and 2 after).
</figcaption>
</figcaption>
</figure>
</figure>
Line 91: Line 125:
 +
<h3> Conclusions </h3>
 +
From the assays performed it can be concluded that:
 +
<li>The two best BioBricks for Landmine detection are LD5 (p[J] incl. N-enzymes) and LD4 (p[F] incl. N-enzymes). The N-genes contribute to sensitivity of the promoters.</li>
 +
<li> The LD5 construct seems to be the most suitable construct for Landmine Detection. </li>
 +
<li> Evidence suggests that the ybiJ and yqjF promoters are activated by 2,4-DNT, but it cannot be totally discarded the possibility that acetonitrile is the trigger of the response of these promoters. </li>
 +
 +
 +
</p>
 +
<br>
<h3> References </h3>
<h3> References </h3>

Latest revision as of 20:24, 17 October 2014

Module Landmine Detection – Characterization

In the wet lab, we made constructs containing the fluorescent protein mKate2 regulated by the ybiJ and yqjF promoters, which are thought to be activated with some chemicals such as 2,4-DNT or 1,3-DNB. Here you can find information with respect to the characterization of the BioBricks for the Landmine Detection module.

As already mentioned, the promoters found to be activated in presence of several chemical compounds that can leak from land mines (ybiJ and yqjF) were coupled to the expression of the fluorescent protein mKate2.

Assays

The different assays used to test our Land Mine BioBricks are:


The different constructs used are:

  • p[F]::mKATE, also referred here as LD2, which corresponds to BioBrick BBa_K1316003
  • p[J]::mKATE, also referred here as LD3, which corresponds to BioBrick BBa_K1316005
  • p[F] incl. N-enzymes, also referred here as LD4, which corresponds to BioBrick BBa_K1316007
  • p[J] incl. N-enzymes, also referred here as LD5, which corresponds to BioBrick BBa_K1316008
  • p[F]::mKATE p[J]::mKATE, also referred here as LD6, which corresponds to BioBrick BBa_K1316009


Plate Reader

A plate reader is a machine designed to handle samples on 6-1536 well format microtiter plates for the measuring of physical properties such as absorbance, fluorescence intensity, luminescence, time-resolved fluorescence, and fluorescence polarisation. Concerning this module, the plate reader device was used for the measurement of fluorescence intensity generated by cells carrying the BioBricks designed to detect land mines. The final protocol developed for Plate reader analysis for this module can be found by clicking on this link.


Results - Plate Reader

Using the different final Landmine detection constructs LD2-6, different concentrations of 2,4-DNT were tested (figure 1). 2,4-DNT, due to safety reasons, was bought in liquid solution dissolved in acetonitrile. To test that the compound triggering the response of the promoters is 2,4-DNT and not acetonitrile, the 0 mg/L 2,4-DNT solution was prepared with the same concentration of acetonitrile contained in the most concentrated 2,4-DNT solution.


The fact that the positive control (constitutively expressed mKate2) presents a clear fluorescence signal at 0 and 50 mg/L, but not at 100 mg/L indicates that high concentrations of 2,4-DNT are toxic for cells after several hours. The toxic compound seems to be 2,4-DNT and not acetonitrile because the sample at 0 mg/L 2,4-DNT (same acetonitrile concentration as the 100 mg/L 2,4-DNT sample) did not kill the cells. Constructs LD2, LD3 and LD6 as well as LD4 and LD5 with no induction of the N-genes show no clear mKate2 induction over time. Not many conclusions can be drawn form LD2 due to the big standard deviation. However, when the N-genes are induced with L-Rhamnose, the constructs LD4 and LD5 showed a clear increase in fluorescence over time for a concentration of 50 mg/L 2,4-DNT. In this situation, besides, LD5 seems to be more sensitive, as there is less leakage (there is less fluorescence signal at 0 mg/L DNT).


It could still be that at 50 mg/L 2,4-DNT, what triggers the response of the promoters is actually the acetonitrile and not the 2,4-DNT, but that would be strange because at 0 mg/L 2,4-DNT (acetonitrile is 2 times more concentrated than at 50 mg/L 2,4-DNT) the cells survive and there is no fluorescence response.


This data suggests that both promoters, ybiJ and yqjF, respond to 2,4-DNT; and that the presence of the N-genes is of high importance for this response. Hence, we conclude that the two best BioBricks for Landmine detection are (in this order) LD5 (p[J] incl. N-enzymes) and LD4 (p[F] incl. N-enzymes), and in order to obtain a good result the N-genes must be expressed.

Figure 1: Fluorescence signal measured on the plate reader. Positive control: constitutively expressed mKate2. Negative control: Empty cells carrying no BioBrick

FACS

Fluorescence-activated cell sorting (FACS) is a specialised type of flow cytometry that allows the separation of individual cells based on the specific light scattering and fluorescent characteristics of each cell. Using FACS, information can be attained of the size, shape and fluorescence of individual cells, therefore, it is a technique that can be used to observe the fluorescent response of our Landminde detection BioBricks in front of DNT.


The FACS technology was used to test the LD2 (p[F]::mKATE) construct. Cultures of this construct were induced with 50 mg/L 2,4-DNT. Aliquots of the culture were taken after 2 and 6 hours; centrifuged and resuspended in PBS solution to eliminate the 2,4-DNT and the acetonitrile; and were then analysed at the FACS machine. At the same time, a strain constitutively expressing mKate2 and an empty strain were used as positive and negative controls respectively. Two cultures of LD2 were used (samples 1 and 2 in figure 2) in order to get the LD2 data in duplo.


The results of the FACS experiments show that the fluorescent response increases with time after induction and, therefore, it means that the yqjF promoter was activated. Figure 2 contains all the LD2 culture (2 and 6 hours after induction), as well as the positive and negative controls. Figure 3 only contains the LD2 culture (2 and 6 hours after induction) and, hence, it provides a more clear picture of the promoter induction. Unfortunately, no solution was prepared containing acetonitrile and water alone and, therefore, we cannot conclude that the induction was caused by 2,4-DNT as it could have been caused by acetonitrile. Nevertheless, as aforementioned, the plate reader results suggests that 2,4-DNT is more likely to be the inducer of the promoters rather than acetonitrile.


Results - FACS

Figure 2: Fluorescence signal emitted by cells carrying constitutively expressed mKate2 (positive control), two parallel samples of the construct LD2 (p[F]::mKATE) (Samples 1 and 2), and empty cells not carrying any BioBrick (negative control) 2 hours after induction (left) and 6 hours after induction (right).
Figure 3: Fluorescence signal emitted by cells carrying the construct LD2 (p[F]::mKATE) of two different cultures (Top and Bottom) 2 hours after DNT induction (samples 1 and 2) and 6 hours after DNT induction (samples 1 after and 2 after).

Conclusions

From the assays performed it can be concluded that:
  • The two best BioBricks for Landmine detection are LD5 (p[J] incl. N-enzymes) and LD4 (p[F] incl. N-enzymes). The N-genes contribute to sensitivity of the promoters.
  • The LD5 construct seems to be the most suitable construct for Landmine Detection.
  • Evidence suggests that the ybiJ and yqjF promoters are activated by 2,4-DNT, but it cannot be totally discarded the possibility that acetonitrile is the trigger of the response of these promoters.

  • References

    [1] S. Yagur-Kroll, S. Belkin et al., “Escherichia Coli bioreporters for the detection of 2,4-dinitrotoluene and 2,4,6-trinitrotoluene”, Appl. Microbiol. Biotechnol. 98, 885-895, 2014.

    Top
    facebook twitter