Team:Sumbawagen/Notebook/protocol4

From 2014.igem.org

(Difference between revisions)
 
Line 212: Line 212:
                     <li><a href="https://2014.igem.org/Team:Sumbawagen/Notebook">Policy & Practices</a></li>
                     <li><a href="https://2014.igem.org/Team:Sumbawagen/Notebook">Policy & Practices</a></li>
                     <li><a href="https://2014.igem.org/Team:Sumbawagen/Notebook2">Lab</a></li>
                     <li><a href="https://2014.igem.org/Team:Sumbawagen/Notebook2">Lab</a></li>
-
                    <li><a href="https://2014.igem.org/Team:Sumbawagen/Notebook3">Mobile Programming</a></li>
 
-
                  <li class="divider"></li>
 
                     <li><a href="https://2014.igem.org/Team:Sumbawagen/Notebook/Protocol">Protocol</a></li>
                     <li><a href="https://2014.igem.org/Team:Sumbawagen/Notebook/Protocol">Protocol</a></li>
                     <!--<li><a href="#">Improvements</a></li>-->
                     <!--<li><a href="#">Improvements</a></li>-->

Latest revision as of 09:17, 19 February 2015

Team:Dundee/Team - 2013.igem.org

 

Team:Sumbawagen/Team

From 2014.igem.org

iGEM Sumbawagen 2014 · Econey

Notebook – Protocol – 4. DNA Purification

Spin column based purification was used. The kit is Gel/PCR extraction kit (Nippon Genetics). Protocols from the kit were followed by adaptation because we have no high speed microcentrifuge, but only a 6,000 rpm small microcentrifuge. All steps were done at room temperature.

DNA Purification from Liquid Samples

    1. Into a clean, sterilized 0.5 ul polypropylene tube, add PCR products : buffer GP1 = 1 : 5 (e.g. 40 ul : 200 ul). Vortexing.

    2. Load the samples onto the spin column equipped with collection tube. Centrifuge for 6,000 rpm; 1 minute. Discard the flowthrough.

    3. Add 600 ul of GP2. Centrifuge for 6,000 rpm; 1 minute. Discard the flowthrough.

    4. Centrifuge for 6,000 rpm; 5 minutes to dry the column.

    5. Replace collecting tube with clean, sterilized 1.5 ml size polypropylene tube.

    6. Add 30 ul of GP3. Incubate 2 minutes at room temperature. Centrifuge for 6,000 rpm; 5 minutes.

    7. Obtain the DNA as the flowthrough.

DNA Purification from Agarose Gel

    1. Into a clean, sterlized 1.5 ul polypropylene tube, add cutted gel containing DNA of interest : buffer GP1 = < 300 mg : 500 ul. Vortexing. Incubate at 55 oC; 10-15 minutes. Invert the tube.

    2. Load the samples onto the spin column equipped with collection tube. Centrifuge for 6,000 rpm; 1 minute. Discard the flowthrough.

    3. Add 600 ul of GP2. Centrifuge for 6,000 rpm; 1 minute. Discard the flowthrough.

    4. Centrifuge for 6,000 rpm; 5 minutes to dry the column.

    5. Replace collecting tube with clean, sterilized 1.5 ml size polypropylene tube

    6. Add 30 ul of GP3. Incubate 2 minutes at room temperature. Centrifuge for 6,000 rpm; 5 minutes.

    7. Obtain the DNA as the flowthrough.