<p>The following method uses the ‘QIAquick  Gel Extraction Kit – Centrifuge Processing Kit’ produced by QIAGEN. All centrifugation steps are at 17,900g/13,000rpm in bench centrifuge. Ensure ethanol has been added to the PE  buffer and that QG buffer is yellow.</p>
 +
<p>CAUTION – ALWAYS WEAR FACE SHIELD AND BUTTON UP LAB COAT FULLY WHEN WORKING AT THE UV LIGHT BOX</p>
 +
<!--this will number your steps 1,2,3,etc-->
<!--this will number your steps 1,2,3,etc-->
-
<ol  style="list-style-type:decimal;">
+
<ol  style="list-style-type:decimal;">  
-
<li>After growing cell cutlers overnight in LB, resuspend pelleted cells in 250 μl Buffer P1 and transfer it into a microcentrifuge tube.<BR><BR>
+
 
-
<li>Add 250 μl of Buffer P2 and mix by inverting the tube 6 times. The cell suspension should turn blue.<BR><BR>
+
<li>Weigh one Eppendorf per each sample to be extracted and label with sample name and Eppendorf mass.<BR><BR>
-
<li>Add 350 μl of Buffer N3 and mix the suspension immediately by inverting 6 times.<BR><BR>
+
 
-
<li>Centrifuge for 10 minutes at 13000 rpm (or 17900 x g). Apply the supernatants to a spin colums<BR><BR>
+
<li>Ensure gel has been stained following [[Staining DNA Gel]] protocol. Place ethidium bromide stained gel on the UV light box. <BR><BR>
-
<li>Centrifuge again for 30-60 seconds and discard the flow-through.<BR><BR>
+
 
-
<li> Wash the spin column by adding 500 μl of the PB buffer and centrifuge for 30-60s.<BR><BR>
+
<li>Ensure face shield is on before turning on UV light box at the wall and turning out main room light.<BR>
-
<li>Discard the flow-through and wash the spin column again by adding 750 uL of PE buffer. Centrifuge for 1 minute.<BR><BR>
+
<font style="font-style:italic">NOTE: Try to minimise the amount of time your DNA samples are exposed to the UV light.</font> <BR><BR>
-
<li>Discard the flow-through and centrifuge again for 1 minute. Now place the column in a 1.5ml microcentrifuge tube.<BR><BR>
+
 
-
<li>Add 50 μl of the EB buffer to the centre of the spin column. Let stand for 2 minutes and centrifuge for 1 minute.<BR><BR>
+
<li>Use razor blade to cut desired band and place in labelled Eppendorf.<BR>
 +
<font style="font-style:italic">NOTE: Try to cut away as much excess gel as possible.</font><BR><BR>
 +
 
 +
<li>Weigh each sample in Eppendorf and calculate mass of sample.  Add 3 gel volumes of QG buffer to each sample.  
 +
<font style="font-style:italic">e.g. Actual mass of gel sample = 0.2g, gel volume = 200 μl, therefore volume of QG buffer added = 600 μl</font><BR><BR>
 +
 
 +
<li>Incubate in 50⁰c water bath for 10 mins to dissolve the gel. Vortex every 2-3 minutes.<BR>
 +
<font style="font-style:italic">NOTE: Keep finger on lid of Eppendorf whilst vortexing.</font><BR><BR>
 +
 
 +
<li>Check the mixture is yellow. If not, add 10 μl 3M Sodium Acetate and mix.<BR><BR>
 +
 
 +
<li>Add 1 gel volume of isopropanol and mix. If no isopropanol on the bench take a Duran bottle and collect some from the store in the cabinet underneath the fume hood. <BR><BR>
 +
 
 +
<li>Place one QIAquick spin column in a 2ml collection tube for each DNA sample. Label both the spin column and collection tube with sample name.<BR><BR>
 +
 
 +
<li>Pipette sample into centre of spin column and centrifuge for 1 min. Discard flow through and replace spin column in collection tube. The DNA should now be bound to the spin column membrane.<BR><BR>
 +
 
 +
<li>Add 0.5 ml of QG buffer to spin column and centrifuge for 1 min. Discard flow through and replace spin column in collection tube.<BR><BR>
 +
 
 +
<li>Add 0.75 ml of PE buffer to spin column and let stand for 2-5mins. Centrifuge for 1 min. Discard flow through and replace spin column in collection tube.<BR><BR>
 +
 
 +
<li>Centrifuge again for 12 min to remove residual buffer. Discard flow through and collection tube.<BR>
 +
<font style="font-style:italic">NOTE: Ethanol from the ethanol supplemented PE buffer can inhibit enzymes. To ensure all ethanol is removed from sample, you can stand spin column on cap on the bench to air dry for 5 mins.</font><BR><BR>
 +
 
 +
<li>Place column in a clean, labelled, 1.5 ml Eppendorf tube.<BR><BR>
 +
 
 +
<li>For Gibson assembly applications a concentrated DNA sample is required, therefore add only 20 μl of EB buffer (elution buffer) to the centre of the spin column membrane. Allow to stand for 4 mins. Centrifuge for 1 min. DNA sample should now be in the flow-through collected in the Eppendorf.<BR>
 +
<font style="font-style:italic">NOTE: When placing spin columns in Eppendorf tubes into the centrifuge position the caps so that they either point in the opposite direction to the centrifuge rotates or down into the centre of the centrifuge.</font><BR><BR>
 +
 
 +
<li>To maximise yield repeat steps 14 and 15 to make a second sample of DNA.<BR><BR>
 +
<li>Use [[Nanodrop: Finding DNA Concentration]] protocol to determine DNA yield.<BR>
 +
<font style="font-style:italic">NOTE: this will not be an exact measurement as QG buffer interferes with UV/vis readings from the nucleic acid.</font><BR><BR>
{{:Team:Oxford/templates/footer}}
{{:Team:Oxford/templates/footer}}

Revision as of 13:45, 23 July 2014

QIAquick Gel Extraction

↩ Back to other protocols.

The following method uses the ‘QIAquick Gel Extraction Kit – Centrifuge Processing Kit’ produced by QIAGEN. All centrifugation steps are at 17,900g/13,000rpm in bench centrifuge. Ensure ethanol has been added to the PE buffer and that QG buffer is yellow.

CAUTION – ALWAYS WEAR FACE SHIELD AND BUTTON UP LAB COAT FULLY WHEN WORKING AT THE UV LIGHT BOX

  1. Weigh one Eppendorf per each sample to be extracted and label with sample name and Eppendorf mass.

  2. Ensure gel has been stained following Staining DNA Gel protocol. Place ethidium bromide stained gel on the UV light box.

  3. Ensure face shield is on before turning on UV light box at the wall and turning out main room light.
    NOTE: Try to minimise the amount of time your DNA samples are exposed to the UV light.

  4. Use razor blade to cut desired band and place in labelled Eppendorf.
    NOTE: Try to cut away as much excess gel as possible.

  5. Weigh each sample in Eppendorf and calculate mass of sample. Add 3 gel volumes of QG buffer to each sample. e.g. Actual mass of gel sample = 0.2g, gel volume = 200 μl, therefore volume of QG buffer added = 600 μl

  6. Incubate in 50⁰c water bath for 10 mins to dissolve the gel. Vortex every 2-3 minutes.
    NOTE: Keep finger on lid of Eppendorf whilst vortexing.

  7. Check the mixture is yellow. If not, add 10 μl 3M Sodium Acetate and mix.

  8. Add 1 gel volume of isopropanol and mix. If no isopropanol on the bench take a Duran bottle and collect some from the store in the cabinet underneath the fume hood.

  9. Place one QIAquick spin column in a 2ml collection tube for each DNA sample. Label both the spin column and collection tube with sample name.

  10. Pipette sample into centre of spin column and centrifuge for 1 min. Discard flow through and replace spin column in collection tube. The DNA should now be bound to the spin column membrane.

  11. Add 0.5 ml of QG buffer to spin column and centrifuge for 1 min. Discard flow through and replace spin column in collection tube.

  12. Add 0.75 ml of PE buffer to spin column and let stand for 2-5mins. Centrifuge for 1 min. Discard flow through and replace spin column in collection tube.

  13. Centrifuge again for 12 min to remove residual buffer. Discard flow through and collection tube.
    NOTE: Ethanol from the ethanol supplemented PE buffer can inhibit enzymes. To ensure all ethanol is removed from sample, you can stand spin column on cap on the bench to air dry for 5 mins.

  14. Place column in a clean, labelled, 1.5 ml Eppendorf tube.

  15. For Gibson assembly applications a concentrated DNA sample is required, therefore add only 20 μl of EB buffer (elution buffer) to the centre of the spin column membrane. Allow to stand for 4 mins. Centrifuge for 1 min. DNA sample should now be in the flow-through collected in the Eppendorf.
    NOTE: When placing spin columns in Eppendorf tubes into the centrifuge position the caps so that they either point in the opposite direction to the centrifuge rotates or down into the centre of the centrifuge.

  16. To maximise yield repeat steps 14 and 15 to make a second sample of DNA.

  17. Use Nanodrop: Finding DNA Concentration protocol to determine DNA yield.
    NOTE: this will not be an exact measurement as QG buffer interferes with UV/vis readings from the nucleic acid.