[DCM] solution-vapour equilibration

Testing the tolerance of E-coli and Pseudomonas strains to various concentrations of DCM (0mM, 5mM, 10mM, 20mM), the 15 mL falcon tube-contained system is modeled as a real binary solution/ideal gas, based on literature solubility data1, confirming negligible [DCM] deviation over the concentration and temperature range used and the validity of taking [DCM] = [DCM] unadjusted.

TDoxigem1.png




V(DCM) added (± 5E-4) /ml

n(DCM)(l) unadjusted (± 8E-6) /mol

[DCM] unadjusted (± 2E-3) /M

p(DCM)

(± 4E-2) /kPa

n(DCM)(g)

(± 4E-7) /mol

n(DCM)(l) (± 9E-6) adjusted /mol

[DCM] adjusted

(± 2E-3) /M

Δ[DCM] /M

[DCM] % deviation

(30°C, 5mM)

1.6E-03

2.5E-05

5.0E-03

6.2E-01

1.6E-08

2.5E-05

5.0E-03

3.1E-06

6.3E-02

(30°C, 10mM)

3.2E-03

5.0E-05

1.0E-02

3.1E-01

7.9E-09

5.0E-05

1.0E-02

1.6E-06

1.6E-02

(30°C, 20mM)

6.4E-03

1.0E-04

2.0E-02

1.6E-01

3.9E-09

1.0E-04

2.0E-02

7.9E-07

3.9E-03











(37°C, 5mM)

1.6E-03

2.5E-05

5.0E-03

6.2E-01

1.5E-08

2.5E-05

5.0E-03

3.1E-06

6.2E-02

(37°C, 10mM)

3.2E-03

5.0E-05

1.0E-02

3.1E-01

7.7E-09

5.0E-05

1.0E-02

1.5E-06

1.5E-02

(37°C, 20mM)

6.4E-03

1.0E-04

2.0E-02

1.6E-01

3.8E-09

1.0E-04

2.0E-02

7.7E-07

3.9E-03


More detailed system modelling is therefore unnecessary.