Team:NCTU Formosa/Safety

From 2014.igem.org

Revision as of 13:35, 6 October 2014 by Alex19950425 (Talk | contribs)

Safety

Change the font size right here

Contents

Researcher safety

1.Everyone must wear lab coat, trousers, gloves, surgery masks and shoes when carrying out experiments.

2.Before the commencement of our project,our team instructors and advisers have guided us to go through every experiment to make sure everybody is well trained and fit for this project.

3.Everybody has to sterilize his/her hands and all the equipment platforms with alcohol solution(70%) before and after each experiment.

4.Emergency equipment is well prepared and all the researchers understand how to use these equipment and their exact position.

5.It is not allowed that researcher carries experiment alone.There must be at least two members to conduct the experiment.

6.Food and beverages are not allowed to appear in the lab.


Public safety

1.All collected lab waste are sterilized, packaged and executed.

2.E.coli used in our lab is less competitive than wild type, because they are unable to form biofilms and to thrive in the intestine.

3.Liquid waste that contains E.coli is disinfected by adding peroxides and cleaners before it is disposed.


Lab instruments

1. Centrifuge

fig.8-1-1

A centrifuge is a kind of equipment generally driven by an electric motor.By rotating in very high speed, it produces a big centrifugal force perpendicular to the axis and rotates an object around a fixed axis. A centrifuge is used to separate the components which have different molecular weight in a mixture. The centrifuge works with the sedimentation principle, where the centripetal acceleration causes denser substances to separate out along the radial direction (the bottom of the tube). Conversely lighter objects will tend to move to the top.1 In our lab, we usually separate E.coli from LB broth and then conduct mini-prep with it.

2. Incubator

fig.8-1-2

The orbital shaker incubator is widely used in microbiology labs, cell biology labs, etc. It provides a stationary temperature to cultivate bacteria and cells. Some incubator also have functions to maintain the humility level. In our lab, the incubator provides stationary temperature at 37 degrees Celsius, which is the optical temperature of E.coli growing, and 16 degrees Celsius for ligase working2. In this year, our team was authorized to work with an non-pathogenic bacterial strain, the Escherichia coli DH5. The strain is regularly employed in research, industry and study. Biosafety Level 1 standard regulations were strictly followed while using these strains.

3. Autoclave

fig.8-1-3

An autoclave is a pressure chamber used to sterilize equipment and supplies by subjecting them to high pressure saturated steam at 121 °C for around 15–20 minutes depending on the size of the load and the contents. The autoclave is used for the safety issue. When sterilizing, the pressure and temperature inside reached high level, forming superheat steam and high pressure which will kill cell and make proteins destroyed or denatured4.

In our lab, every consumables that may contact bacteria will be sterilized before and after use to guarantee the safety.

4. Laminar flow

fig.8-1-4

A laminar flow is an enclosed, ventilated laboratory workspace for safely working with materials contaminated with (or potentially contaminated with) pathogens requiring a defined biosafety level.we usually conduct experiments where our E.coli will expose, such as selecting single colony 7. We strictly rule that all of the researchers should conduct experiments carefully inside the laminar flow and sterilize his/her hands with alcohol solution(70%) before conducting experiments, all of us are familiar with the using method of Laminar flow.</p>

5. Balance

fig.8-1-5

An analytical balance is a class of balance used in measuring small mass in the sub-milligram range. The measuring pan of an analytical balance is inside a transparent enclosure with doors so that dust can be collected well and so any air currents in the room do not affect the balance's accuracy.5 In our lab, we have two models of balance, one is accurate to 0.1 g, another is accurate to 0.1 mg.

6. Water purify system

fig.8-1-6

In this system, Water is purified in a first step using unique Jetpore ion-exchange resin, synthetic activated carbon and UV lamp emitting at 185 and 254 nm to reach a resistivity of 18.2 MΩ.cm at 25 °C and a TOC value below 5 ppb, both monitored by advanced analytical techniques.6 The water purify system is used to produce ultrapure water, which is for experimental use in our lab.

7. Thermal cycler

fig.8-1-7

The thermal cycler (also known as a thermocycler, PCR machine or DNA amplifier) is a laboratory apparatus that are most commonly used to amplify segments of DNA via the polymerase chain reaction (PCR). The function of thermal cycle is to provide the appropriate working temperature for some reactions, including many temperature-sensitive reactions such as restriction enzyme digestion or rapid diagnostics. The device has a thermal block with holes where tubes holding the reaction mixtures can be inserted. The cycler then raises and lowers the temperature of the block in discrete, pre-programmed steps, and time setting determines the time interval of every temperature3

8. Gel Documentation System

fig.8-1-8

Gel documentation system, also known as a gel image system or gel imager, is equipment widely used in molecular biology laboratories for the imaging and documentation of nucleic acid and protein suspended within polyacrylamide or agarose gels. These gels are typically stained with ethidium bromide or other fluorophores such as SYBR Green. Generally, a gel doc includes an ultraviolet (UV) light transilluminator, a hood or a darkroom to shield external light sources and protect the user from UV exposure, and a CCD camera for image capturing8.


Reference
  1. ]Biological Centrifugation, by D. Rickwood, J.M. Graham (2001). Springer Verlag; ISBN: 0387915761
  2. Incubator (culture), from Wikipedia,http://en.wikipedia.org/wiki/Incubator_(culture)
  3. Weier, HU; Gray, JW (Jul–Aug 1988). "A programmable system to perform the polymerase chain reaction.". DNA (Mary Ann Liebert, Inc.) 7 (6): 441–7. PMID 3203600
  4. Seymour Stanton Block (2001). Disinfection, Sterilization, and Preservation. Lippincott Williams & Wilkins. ISBN 978-0-683-30740-5. Retrieved 19 January 2013
  5. "A&D training material" by Marketing Department A&D Company. Analytical balance, from Wikipedia ,http://en.wikipedia.org/wiki/Analytical_balance
  6. Milli-Q Direct, made by EMD Millipore, http://www.millipore.com/catalogue/module/C85358
  7. "The Safe Use of Biological Safety Cabinets" by Environmental Health and Radiation Safety
  8. E-BOX VX5 Gel Documentation System, made by Vilber Lourmat, http://www.fisherbiotec.com.au/shop/product/e-box_vx5_gel_documentation_system/3. Gel Documentation System, from Wikipedia, http://en.wikipedia.org/wiki/Gel_doc

Safety form

1. About Our Lab Form

NCTU-about our lab-1.PNG

NCTU-about our lab-2.PNG

NCTU-about our lab-3.PNG

NCTU-about our lab-4.PNG

NCTU-about our lab-5.PNG

NCTU-about our lab-6.PNG

NCTU-about our lab-7.PNG

2. Check-In Form

3. Safety Form

NCTU-Safety form-2.PNG

NCTU-Safety form-3.PNG

NCTU-Safety form-4.PNG

NCTU-Safety form-5.PNG

NCTU-Safety form-6.PNG

NCTU-Safety form-7.PNG

NCTU-Safety form-8.PNG

NCTU-Safety form-9.PNG