We want to add a color system which shows whether it's <i>S. aureus</i> or <i>P. aeruginosa</i> which is infecting the wound. Preferably this will activate as soon as the first bacteria is in sight. There is work done with GFP, this could be combined with RFP as well
+
We want to add a color system which shows whether there is an infection of <i>S. aureus</i> or <i>P. aeruginosa</i> in the wound. The detection will activate as soon as the first bacteria is in sight. For the testing the detection constructs can be coupled to a GFP(or a lumniscent) signal.
</div>
</div>
<div class="hspacer">&nbsp;</div>
<div class="hspacer">&nbsp;</div>
Line 31: Line 31:
<!-- PARAGRAPH SNIPPET START-->
<!-- PARAGRAPH SNIPPET START-->
<div class="text">
<div class="text">
-
Our bandage should be transparent. This way you can look through it and judge whether it should be changed or it can stay on for another day. Seeing through the bandage without having to remove it is one of the criteria for the burn wound center as well.  
+
Our bandage should be transparent. In this way you can look through the bandage and judge whether it should be changed or it can stay on for another day, or whether you need to see a doctor. Seeing through the bandage without having to remove it is one of the criteria for the burn wound center as well.  
-
Of course the bandage should be as thin as possible. We're aiming at a maximum thickness of one centimeter, and preferably ever thinner.
+
Of course the bandage should be as thin as possible. We are aiming at a maximum thickness of one centimeter and a minimum thickness of 3 millimeter.
</div>
</div>
<div class="hspacer">&nbsp;</div>
<div class="hspacer">&nbsp;</div>
Line 47: Line 47:
<!-- PARAGRAPH SNIPPET START-->
<!-- PARAGRAPH SNIPPET START-->
<div class="text">
<div class="text">
-
We have to make sure our bacteria stays inside the gel. Although it's unlikely that <i> L. lactis </i> infects a human, when immuno-compromised this is a possible. We can make sure the bacteria can't leave the bandage by adjusting the pore-size of this gel. Another extra safety point is the usage of a bottom membrane. This is membrane with a pore-size of 0.2um to make sure our molecules can diffuse, but the bacteria are stuck.
+
We have to make sure our bacteria stays inside the gel. Although it is unlikely that <i> L. lactis </i> infects a human, it is possible when the immune system is compromised. We can make sure the bacteria can not leave the bandage by adjusting the pore-size of this gel. Another extra safety point is the usage of a bottom membrane. This membrane will have a pore-size of 0.2um to make sure our molecules can diffuse, but the bacteria are stuck inside.
-
Since we're aiming for hospital usage we'd think that after use this bandage should be autoclaved, after that thrown away in the normal waste.
+
Since we are aiming for hospital usage the bandage can be autoclaved or burned after use, and thrown away in the regular waste.
</div>
</div>
<div class="hspacer">&nbsp;</div>
<div class="hspacer">&nbsp;</div>
Line 65: Line 65:
<!-- PARAGRAPH SNIPPET START-->
<!-- PARAGRAPH SNIPPET START-->
<div class="text">
<div class="text">
-
The bandage shouldn't stick, burn wounds are painful enough as is and we don't want to add to that. Another thing is how easy the bandage can be activated. This should be within 30 minutes and as easy as possible. Also one of the problems could be how thick the bandage is, it needs to be as thin as possible to be decent to wear.
+
The bandage should not stick, burns are painful wounds and we don't want to make it worse. Secondly it is important that the bandage can be activated easily. This should be within 30 minutes minimize the risk of getting infected. Also one of the requirements is the thickness the bandage, and mainly the thickness of the hydrogel. The thinner the bandage is the quicker the diffusion, and thus the quicker the treatment. Also the flexibillity of the bandage is important, the bandage should be waerable.
-
We'd like to add a plastic mash inside the bandage, this way it can bend without breaking completely
+
</div>
</div>
<div class="hspacer">&nbsp;</div>
<div class="hspacer">&nbsp;</div>

Latest revision as of 03:42, 18 October 2014

Measurements
 
We want to add a color system which shows whether there is an infection of S. aureus or P. aeruginosa in the wound. The detection will activate as soon as the first bacteria is in sight. For the testing the detection constructs can be coupled to a GFP(or a lumniscent) signal.
 
Appearance
 
Our bandage should be transparent. In this way you can look through the bandage and judge whether it should be changed or it can stay on for another day, or whether you need to see a doctor. Seeing through the bandage without having to remove it is one of the criteria for the burn wound center as well. Of course the bandage should be as thin as possible. We are aiming at a maximum thickness of one centimeter and a minimum thickness of 3 millimeter.
 
Safety
 
We have to make sure our bacteria stays inside the gel. Although it is unlikely that L. lactis infects a human, it is possible when the immune system is compromised. We can make sure the bacteria can not leave the bandage by adjusting the pore-size of this gel. Another extra safety point is the usage of a bottom membrane. This membrane will have a pore-size of 0.2um to make sure our molecules can diffuse, but the bacteria are stuck inside. Since we are aiming for hospital usage the bandage can be autoclaved or burned after use, and thrown away in the regular waste.
 
Comfort & User friendliness
 
The bandage should not stick, burns are painful wounds and we don't want to make it worse. Secondly it is important that the bandage can be activated easily. This should be within 30 minutes minimize the risk of getting infected. Also one of the requirements is the thickness the bandage, and mainly the thickness of the hydrogel. The thinner the bandage is the quicker the diffusion, and thus the quicker the treatment. Also the flexibillity of the bandage is important, the bandage should be waerable.