Team:ETH Zurich/labblog/20140611meet

From 2014.igem.org

(Difference between revisions)
(Wednesday, June 11th)
(Week 3)
 
(17 intermediate revisions not shown)
Line 1: Line 1:
-
<html><article class="meetings" id="20140604"></html>
+
<html><article class="mix meetings carousel" id='week3' date="20140604"></html>
-
== Week 3  ==  
+
== Week 3: Plasmid design started, Modeling started ==  
==== Wednesday, June 11th ====
==== Wednesday, June 11th ====
* We started plasmid design :
* We started plasmid design :
-
[[File:ETH Zurich Plasmids.png|600px]]
+
[[File:ETH Zurich Plasmids.png|center|600px|thumb|First draft of plasmids|First draft of plasmids. The sensor plasmid is the same in every cell. Different logic + repressors plasmids are present in cells p and q. The logic + repressors plasmid from cells p is producing the quorum sensing molecule p, and another version is present in cells q which produces QSq. Colonies of p and q cells will be arranged in an alternate way on the millifluidic chip. Here as an example we use the lux system for p cells and the rhl system for q cells.]]
-
&Phi;C31 and Bxb1 are integrases. LuxR an RhlR are quorum sensing molecules. Type p colonies produce AHL by expressing the enzyme LuxI. Type q colonies produce Rhl by expressing the enzyme RhlI. In fact, we don't know yet which quorum sensing systems we will use. We will have to perform cross-talk experimetns in order to choose the ones that are the most orthogonal.
+
&Phi;C31 and Bxb1 are integrases. LuxR an RhlR are quorum sensing repressors. A riboswitch construct is placed around quorum sensing constructs to prevent leakiness of lux and rhl promoters. Type p colonies produce AHL by expressing the enzyme LuxI. Type q colonies produce Rhl by expressing the enzyme RhlI. In fact, we don't know yet which quorum sensing systems we will use. We will have to perform cross-talk experimetns in order to choose the ones that are the most orthogonal.
* We tried to print our first agar millifluidic chip : we printed it too small, and the printer had resolution problems.
* We tried to print our first agar millifluidic chip : we printed it too small, and the printer had resolution problems.
* We wrote all reactions and found parameters from the literature for our model.
* We wrote all reactions and found parameters from the literature for our model.
 +
{{:Team:ETH Zurich/tpl/topbutton|silver}}
-
[[#top|Top]]
+
{{:Team:ETH Zurich/tpl/rmbutton|silver|week3}}
-
<html></article></html>
+
 
 +
<html> </article></html>

Latest revision as of 22:00, 11 October 2014